U-net based metal segmentation on projection domain for metal artifact reduction in dental CT
- 29 April 2019
- journal article
- research article
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 9 (3) , 375-385
Abstract
Unlike medical computed tomography (CT), dental CT often suffers from severe metal artifacts stemming from high-density materials employed for dental prostheses. Despite the many metal artifact reduction (MAR) methods available for medical CT, those methods do not sufficiently reduce metal artifacts in dental CT images because MAR performance is often compromised by the enamel layer of teeth, whose X-ray attenuation coefficient is not so different from that of prosthetic materials. We propose a deep learning-based metal segmentation method on the projection domain to improve MAR performance in dental CT. We adopted a simplified U-net for metal segmentation on the projection domain without using any information from the metal-artifacts-corrupted CT images. After training the network with the projection data of five patients, we segmented the metal objects on the projection data of other patients using the trained network parameters. With the segmentation results, we corrected the projection data by applying region filling inside the segmented region. We fused two CT images, one from the corrected projection data and the other from the original raw projection data, and then we forward-projected the fused CT image to get the fused projection data. To get the final corrected projection data, we replaced the metal regions in the original projection data with the ones in the fused projection data. To evaluate the efficacy of the proposed segmentation method on MAR, we compared the MAR performance of the proposed segmentation method with a conventional MAR method based on metal segmentation on the CT image domain. For the MAR performance evaluation, we considered the three primary MAR performance metrics: the relative error (REL), the sum of square difference (SSD), and the normalized absolute difference (NAD). The proposed segmentation method improved MAR performances by around 5.7% for REL, 6.8% for SSD, and 8.2% for NAD. The proposed metal segmentation method on the projection domain showed better MAR performance than the conventional segmentation on the CT image domain. We expect that the proposed segmentation method can improve the performance of the existing MAR methods that are based on metal segmentation on the CT image domain.Keywords
Funding Information
- National Research Foundation of Korea (2015M2A2A7A03043177)
This publication has 32 references indexed in Scilit:
- Dental CT metal artefact reduction based on sequential substitutionDentomaxillofacial Radiology, 2011
- A Review of Factors That Affect Artifact From Metallic Hardware on Multi-Row Detector Computed TomographyCurrent Problems in Diagnostic Radiology, 2010
- A novel forward projection-based metal artifact reduction method for flat-detector computed tomographyPhysics in Medicine & Biology, 2009
- An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studiesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstructionMedical Physics, 2002
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- A post-processing algorithm to reduce metallic clip artifacts in CT imagesEuropean Radiology, 1993
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984
- Computed Tomography Reconstruction from Hollow ProjectionsJournal of Computer Assisted Tomography, 1979
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945