Hand-held dynamic contour tonometry
- 23 February 2011
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 89 (2) , 132-137
Abstract
Purpose: We present a prototype of the hand-held dynamic contour tonometer (HH-DCT) and prospectively compare this HH-DCT with the well-established Perkins applanation tonometer (PAT) and the TonoPenXL (TPXL). Methods: In a prospective, single-centre, randomized study, intraocular pressure (IOP) readings were taken in random order using HH-DCT, PAT and TPXL tonometers. Intra-observer variability was calculated for each observer and compared between three experienced ophthalmologists and an inexperienced medical student. Results: Ninety-two corneas of 92 healthy participants were enrolled. IOP [mean mmHg +/- standard deviation (SD)] as measured by HH-DCT was 16.97 +/- 2.71, by PAT 13.98 +/- 2.52 and by TPXL 13.34 +/- 2.68. The range of three consecutive IOP readings differed significantly between the devices [p < 0.001; mean range: 1.45 +/- 1.07 (HH-DCT), 1.87 +/- 0.97 (PAT) and 2.08 +/- 1.77 (TPXL)]. There was no difference of the range in all devices between the ophthalmologists and the medical student (HH-DCT p = 0.68, PAT p = 0.54, TPXL p = 0.48). Conclusion: IOP readings measured by HH-DCT are significantly higher than by PAT and TPXL. The differences of IOP measurements are in good accordance with previous studies using the slit-lamp-mounted DCT (SL-DCT) and Goldmann Applanation Tonometry, where SL-DCT readings were 1-3.2 mmHg higher. HH-DCT seems to give more constant results, which can be seen in the lower intra-observer variability compared to PAT and TPXLKeywords
This publication has 22 references indexed in Scilit:
- Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practiceActa Ophthalmologica, 2009
- Pascal, ICare and Goldmann applanation tonometry – a comparative studyActa Ophthalmologica, 2008
- Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyesEye, 2008
- Central Corneal Thickness—Tonometry Artifact, or Something More?Ophthalmology, 2007
- Role of Corneal Elasticity in Damping of Intraocular PressureInvestigative Ophthalmology & Visual Science, 2007
- Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiological studiesGraefe's Archive for Clinical and Experimental Ophthalmology, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- BIOMETRIC CORRELATIONS OF CORNEAL THICKNESSActa Ophthalmologica, 1975
- Simple Hand Applanation Tonometer: For use on the Seated as Well as on the Supine PatientAmerican Journal of Ophthalmology, 1966
- Über ApplanationstonometrieOphthalmologica, 1957