Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms
Authors:
- Gatha AdhikariGAGatha Adhikari
- Venkata Polavarapu SarojasamhitaVSVenkata Polavarapu Sarojasamhita
- Vené Richardson-PowellVRVené Richardson-Powell
- Asma FarooquiAFAsma Farooqui
- Maya BudzinskiMBMaya Budzinski
- Jeffrey YangJYJeffrey Yang
- David KatzDKDavid Katz
- Brian CrouchBrian Crouch
- Nimmi RamanujamNRNimmi Ramanujam
- Jenna L. MuellerJMJenna L. Mueller
- 7 December 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (5) , 1488-1498
Abstract
Objective: Local drug delivery aims to minimize systemic toxicity by preventing off-target effects; however, injection parameters influencing depot formation of injectable gels have yet to be thoroughly studied. We explored the effects of needle characteristics, injection depth, rate, volume, and polymer concentration on gel ethanol distribution in both tissue and phantoms. Methods: The polymer ethyl cellulose (EC) was added to ethanol to form an injectable gel to ablate cervical precancer and cancer. Tissue mimicking phantoms composed of 1% agarose dissolved in deionized water were used to establish overall trends between various injection parameters and the resulting gel distribution. Additional experiments were performed in excised swine cervices with a CT-imageable injectate formulation, which enabled visualization of the distribution without tissue sectioning. Results: Needle type and injection rate had minimal impact on gel distribution, while needle depths ≥13 mm yielded significantly larger distributions. Needle gauge and EC concentration impacted injection pressure with maximum gel distribution achieved when the pressure was 70–250 kPa. Injection volumes ≤3 mL of 6% EC-ethanol minimized fluid leakage away from the injection site. Results guided the development of a speculum-compatible hand-held injector to deliver gel ethanol into the cervix. Conclusion: Needle depth, gauge, and polymer concentration are critical to consider when delivering injectable gels. Significance: This study addressed key questions related to the impact of injection-based parameters on gel distribution at a scale relevant to human applications including: 1) how best to deliver EC-ethanol into the cervix and 2) general insights about injection protocols relevant to the delivery of injectable gels in tissue.Keywords
Funding Information
- National Institutes of Health (R00CA234455, R01CA239268, R43CA257303)
This publication has 39 references indexed in Scilit:
- In situ evaluation of spatiotemporal distribution of doxorubicin from Drug-eluting Beads in a tissue mimicking phantomEuropean Journal of Pharmaceutical Sciences, 2021
- Assessment of Image-Guided Intratumoral Delivery of Immunotherapeutics in Patients With CancerJAMA Network Open, 2020
- Advances in immunotherapy delivery from implantable and injectable biomaterialsActa Biomaterialia, 2019
- Revised FIGO staging for carcinoma of the cervix uteriInternational Journal of Gynecology & Obstetrics, 2019
- Regulation of Inflammatory Cytokines for Spinal Cord Injury Repair Through Local Delivery of Therapeutic AgentsAdvanced Science, 2018
- Synergistic anti-tumor activity through combinational intratumoral injection of an in-situ injectable drug depotBiomaterials, 2016
- Effect of Needle Size on Pain Perception in Patients Treated With Botulinum Toxin Type A InjectionsJAMA Dermatology, 2015
- Numerical study of nanofluid infusion in deformable tissues for hyperthermia cancer treatmentsMedical & Biological Engineering & Computing, 2011
- Coupled macromolecular transport and gel mechanics: Poroviscoelastic approachAIChE Journal, 2003
- Hepatic vascular and bile duct injury after ethanol injection therapy for hepatocellular carcinomaGastrointestinal Radiology, 1992