  • In Vitro Hemolysis Evaluation of the Second Heart Assist Whisper Percutaneous Mechanical Circulatory Support Device

    by Chris H. H. Chan, Asma Farooqui, Preston Peak, Yaxin Wang, Sai Kode, Hadeel Al‐Sahli, Zvonimir Krajcer, Sejal Chaudhari, Alex Richardson, Leslie Miller

    Background: High rotational pump speeds in percutaneous mechanical circulatory support (pMCS) devices frequently result in hemolysis. Consequently, in vitro hemolysis testing for newly developed devices is essential to mitigate this significant risk. This study compared the degree of hemolysis induced by the Second Heart Assist Whisper pMCS at its maximum pump speed, representing the worst‐case scenario, with that of the Impella CP, following American society for testing and materials standards. Methods: Five Whisper devices were tested at 10000 RPM, while a comparator Impella CP was operated at 44 133 ± 606 RPM to match the Whisper's flow rate. Both devices were evaluated in two identical in vitro blood circulatory loops using citrated bovine blood. Hemolysis was analyzed by the tetramethylbenzidine method. Results: The change in plasma free hemoglobin (Δ pf Hb) was significantly greater with the Impella CP than with the Whisper ( p < 0.01). Both devices caused a steady increase in pf Hb, with significant differences after 60 min of in vitro testing ( p < 0.01). The Whisper and Impella CP differed significantly in normalized index of hemolysis (0.088 ± 0.022 vs. 0.194 ± 0.029 g/100, p < 0.01) and modified index of hemolysis (9.72 ± 2.4 vs. 20.83 ± 3.5, p < 0.01). Conclusion: The Whisper exhibited superior hemolytic performance to that of the Impella CP under identical hemodynamic conditions. Our newly designed blood circulatory loop and these benchmark values will aid future in vitro hemolysis testing for pMCS devices.


  • Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms

    by Gatha Adhikari, Venkata Polavarapu Sarojasamhita, Vené Richardson-Powell, Asma Farooqui, Maya Budzinski, David T. Garvey, Jeffrey Yang, David Katz, Brian Crouch, Nimmi Ramanujam, et al.

    Objective: Local drug delivery aims to minimize systemic toxicity by preventing off-target effects; however, injection parameters influencing depot formation of injectable gels have yet to be thoroughly studied. We explored the effects of needle characteristics, injection depth, rate, volume, and polymer concentration on gel ethanol distribution in both tissue and phantoms. Methods: The polymer ethyl cellulose (EC) was added to ethanol to form an injectable gel to ablate cervical precancer and cancer. Tissue mimicking phantoms composed of 1% agarose dissolved in deionized water were used to establish overall trends between various injection parameters and the resulting gel distribution. Additional experiments were performed in excised swine cervices with a CT-imageable injectate formulation, which enabled visualization of the distribution without tissue sectioning. Results: Needle type and injection rate had minimal impact on gel distribution, while needle depths ≥13 mm yielded significantly larger distributions. Needle gauge and EC concentration impacted injection pressure with maximum gel distribution achieved when the pressure was 70–250 kPa. Injection volumes ≤3 mL of 6% EC-ethanol minimized fluid leakage away from the injection site. Results guided the development of a speculum-compatible hand-held injector to deliver gel ethanol into the cervix. Conclusion: Needle depth, gauge, and polymer concentration are critical to consider when delivering injectable gels. Significance: This study addressed key questions related to the impact of injection-based parameters on gel distribution at a scale relevant to human applications including: 1) how best to deliver EC-ethanol into the cervix and 2) general insights about injection protocols relevant to the delivery of injectable gels in tissue.