Abstract
The ultimate bearing capacity of a group of equally spaced multiple rough strip footings was determined due to the contribution of soil unit weight. The analysis was performed by using an upper bound theorem of limit analysis in combination with finite elements and linear programming. Along the interfaces of all the triangular elements, velocity discontinuities were considered. The value of ξγ was found to increase continuously with a decrease in S/B, where (i) ξγ is the ratio of the failure load of an interfering strip footing of a given width (B) to that of a single isolated strip footing having the same width and (ii) S is the clear spacing between any two adjacent footings. The effect of the variation of spacing on ξγ was found to be very extensive for small values of S/B; ξγ approaches infinity at S/B=0. In all the cases, the velocity discontinuities were found to exist generally in a zone only around the footing edge. Copyright © 2008 John Wiley & Sons, Ltd.

This publication has 12 references indexed in Scilit: