Best Estimate Plus Uncertainty (BEPU) methodologies are gradually establishing themselves as the favored way to perform Deterministic Safety Assessments of Nuclear Power Plants, because they account for uncertainties in plant states and physical behaviors while employing accurate-to-reality (best estimate) simulation codes. This work is performed in the context of the ATRIUM project, which seeks to establish best practices and standardize the BEPU process to make the results more consistent, minimizing user effect. The approach taken in this project is to focus on specific phenomenology that is crucial to the progression of the desired transient (a Loss of Coolant Accident), and work with Separate Effect Test experiments to find adequate uncertain parameters and their probability density function, to be forward propagated through BEPU methods.In this article, the specific target phenomenology is the post-critical heat flux heat transfer mechanism, more precisely film boiling heat transfer. Within ATRIUM, three experiment programs were proposed to evaluate the target phenomena: Becker, Stewart, and THTF. Firstly, the adequacy of the different experiments was evaluated along with preliminary RELAP5 simulations. The analysis highlighted the difficulties to reproduce some of the experiments and a final subset of tests was selected for inverse uncertainty quantification.Afterwards, a thorough sensitivity analysis was performed on the physical parameters that may influence the target phenomena, which helped identify the most influential parameters that are sufficient to minimize the error with the experiment. A novel IUQ methodology was then applied to these uncertain parameters and validated through BEPU analyses.