Real-time 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy
Open Access
- 23 July 2013
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 52 (7) , 1464-1471
Abstract
Intra-fractional respiratory motion during radiotherapy leads to a larger planning target volume (PTV). Real-time tumor motion tracking by two-dimensional (2D)/3D registration using on-board kilo-voltage (kV) imaging can allow for a reduction of the PTV though motion along the imaging beam axis cannot be resolved using only one projection image. We present a retrospective patient study investigating the impact of paired portal mega-voltage (MV) and kV images on registration accuracy. Material and methods. We used data from 10 patients suffering from non-small cell lung cancer (NSCLC) undergoing stereotactic body radiation therapy (SBRT) lung treatment. For each patient we acquired a planning computed tomography (CT) and sequences of kV and MV images during treatment. We compared the accuracy of motion tracking in six degrees-of-freedom (DOF) using the anterior-posterior (AP) kV sequence or the sequence of kV-MV image pairs. Results. Motion along cranial-caudal direction could accurately be extracted when using only the kV sequence but in AP direction we obtained large errors. When using kV-MV pairs, the average error was reduced from 2.9 mm to 1.5 mm and the motion along AP was successfully extracted. Mean registration time was 188 ms. Conclusion. Our evaluation shows that using kV-MV image pairs leads to improved motion extraction in six DOF and is suitable for real-time tumor motion tracking with a conventional LINAC.Keywords
This publication has 20 references indexed in Scilit:
- Image-Guided Robotic Stereotactic Radiation Therapy with Fiducial-Free Tumor Tracking for Lung CancerRadiation Oncology, 2012
- A Novel Markerless Technique to Evaluate Daily Lung Tumor Motion Based on Conventional Cone-Beam CT Projection DataInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- An evaluation of intrafraction motion of the prostate in the prone and supine positions using electromagnetic trackingRadiotherapy and Oncology, 2011
- Validation for 2D/3D registration II: The comparison of intensity‐ and gradient‐based merit functions using a new gold standard data setMedical Physics, 2011
- Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator TrackingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Markerless lung tumor tracking and trajectory reconstruction using rotational cone-beam projections: a feasibility studyPhysics in Medicine & Biology, 2010
- Assessment of two novel ventilatory surrogates for use in the delivery of gated/tracked radiotherapy for non-small cell lung cancerRadiotherapy and Oncology, 2009
- Geometric uncertainty of 2D projection imaging in monitoring 3D tumor motionPhysics in Medicine & Biology, 2007
- Errors and margins in radiotherapySeminars in Radiation Oncology, 2004
- Robotic Motion Compensation for Respiratory Movement during RadiosurgeryComputer Aided Surgery, 2000