Abstract
Background: The Low-profile Visible Intraluminal Support device (LVIS Jr) has become a commonly used intracranial stent for the treatment of intracranial aneurysms. However long-term stability and effectiveness remains to be seen. The purpose of the study was to assess the long-term efficacy, safety and durability of LVIS Jr. in a retrospective multicenter registry. Methods: Patients with saccular aneurysms treated at centers across Canada using LVIS Jr for intracranial aneurysms were included in this retrospective registry between the dates of January 2013 and April 2019. Self reported outcomes were collected and used to assess both perioperative and long term safety and effectiveness. Both univariate and multivariate analysis were performed. Results: Total of 196 patients (132 Women; mean age of 57.6 years) underwent endovascular aneurysm treatment with at least 1 LVIS Jr. stent. Mean aneurysm dome size was 7.4 mm, and mean neck size of 4.3 mm. Mean clinical and imaging follow up were 950 and 899 days respectively. Class I/II was achieved in 85% on long term follow up. Periprocedural morbidity and mortality was 4.6% and 2% and additional delayed morbidity and mortality was 3% and 2.5%. Aneurysm size >10 mm was independent predictor of periprocedural complication (OR 2.59, p = 0.048) while an increased dome to neck ratio >1.5 was independent predictor of increased delayed complications (OR 3.99, p = 0.02). Conclusion: The LVIS Jr. intracranial stent is an effective device in the treatment of intracranial aneurysms. Satisfactory long term occlusion rates can be achieved safely with stent-assisted coil embolization.Keywords
This publication has 30 references indexed in Scilit:
- Complication analysis in nitinol stent-assisted embolization of 486 intracranial aneurysmsJournal of Neurosurgery, 2015
- The LVIS/LVIS Jr. stents in the treatment of wide-neck intracranial aneurysms: multicentre registryJournal of NeuroInterventional Surgery, 2014
- Low-profile Visualized Intraluminal Support device (LVIS Jr) as a novel tool in the treatment of wide-necked intracranial aneurysms: initial experience in 32 casesJournal of NeuroInterventional Surgery, 2014
- Stent-Assisted Coiling in Endovascular Treatment of 500 Consecutive Cerebral Aneurysms with Long-Term Follow-UpAmerican Journal of Neuroradiology, 2013
- SILK flow diverter for treatment of intracranial aneurysms: initial experience and cost analysisJournal of NeuroInterventional Surgery, 2013
- Endovascular Treatment of Intracranial Aneurysms With Flow DivertersStroke, 2013
- A Comparison of Functional and Physical Properties of Self-Expanding Intracranial Stents [Neuroform3, Wingspan, Solitaire, Leo(+), Enterprise]min - Minimally Invasive Neurosurgery, 2011
- Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registryJournal of Neurosurgery, 2009
- PRELIMINARY EXPERIENCE WITH THE ENTERPRISE STENT FOR ENDOVASCULAR TREATMENT OF COMPLEX INTRACRANIAL ANEURYSMSNeurosurgery, 2008
- Endovascular Treatment of Unruptured AneurysmsStroke, 2001