Howard Lesiuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Howard Lesiuk has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Alain Weill
Department of Radiology, Centre hospitalier de l'Université de Montréal (CHUM), Hopital Notre-Dame, Montreal, Quebec, Canada
3 shared publications - Brian Drake
University of Ottawa
3 shared publications - Daniel Roy
Centre Hospitalier de l’Université de Montréal, Montreal, Canada
3 shared publications - Daniela Iancu
Canadian Interventional Neuro Group (CING)
3 shared publications - Jean Raymond
Department of Radiology, service of Neuroradiology, Centre hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada
3 shared publications - Jeremy L. Rempel
Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Canada (J.L.R.).
2 shared publications
Latest Publications
- Open Access
- 16 March 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (4) , 381-389
Stent-Assisted Coiling in the Treatment of Unruptured Intracranial Aneurysms: A Randomized Clinical Trial
BACKGROUND AND PURPOSE: Stent-assisted coiling may improve angiographic results of endovascular treatment of unruptured intracranial aneurysms compared with coiling alone, but this has never been shown in a randomized trial. MATERIALS AND METHODS: The Stenting in the Treatment of Aneurysm Trial was an investigator-led, parallel, randomized (1:1) trial conducted in 4 university hospitals. Patients with intracranial aneurysms at risk of recurrence, defined as large aneurysms (≥10 mm), postcoiling recurrent aneurysms, or small aneurysms with a wide neck (≥4 mm), were randomly allocated to stent-assisted coiling or coiling alone. The composite primary efficacy outcome was “treatment failure,” defined as initial failure to treat the aneurysm; aneurysm rupture or retreatment during follow-up; death or dependency (mRS > 2); or an angiographic residual aneurysm adjudicated by an independent core laboratory at 12 months. The primary hypothesis (revised for slow accrual) was that stent-assisted coiling would decrease treatment failures from 33% to 15%, requiring 200 patients. Primary analyses were intent to treat. RESULTS: Of 205 patients recruited between 2011 and 2021, ninety-four were allocated to stent-assisted coiling and 111 to coiling alone. The primary outcome, ascertainable in 203 patients, was reached in 28/93 patients allocated to stent-assisted coiling (30.1%; 95% CI, 21.2%–40.6%) compared with 30/110 (27.3%; 95% CI, 19.4%–36.7%) allocated to coiling alone (relative risk = 1.10; 95% CI, 0.7–1.7; P = .66). Poor clinical outcomes (mRS >2) occurred in 8/94 patients allocated to stent-assisted coiling (8.5%; 95% CI, 4.0%–16.6%) compared with 6/111 (5.4%; 95% CI, 2.2%–11.9%) allocated to coiling alone (relative risk = 1.6; 95% CI, 0.6%–4.4%; P = .38). CONCLUSIONS: The STAT trial did not show stent-assisted coiling to be superior to coiling alone for wide-neck, large, or recurrent unruptured aneurysms.
- 16 March 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (4) , 381-389
Open AccessStent-Assisted Coiling in the Treatment of Unruptured Intracranial Aneurysms: A Randomized Clinical Trial
BACKGROUND AND PURPOSE: Stent-assisted coiling may improve angiographic results of endovascular treatment of unruptured intracranial aneurysms compared with coiling alone, but this has never been shown in a randomized trial. MATERIALS AND METHODS: The Stenting in the Treatment of Aneurysm Trial was an investigator-led, parallel, randomized (1:1) trial conducted in 4 university hospitals. Patients with intracranial aneurysms at risk of recurrence, defined as large aneurysms (≥10 mm), postcoiling recurrent aneurysms, or small aneurysms with a wide neck (≥4 mm), were randomly allocated to stent-assisted coiling or coiling alone. The composite primary efficacy outcome was “treatment failure,” defined as initial failure to treat the aneurysm; aneurysm rupture or retreatment during follow-up; death or dependency (mRS > 2); or an angiographic residual aneurysm adjudicated by an independent core laboratory at 12 months. The primary hypothesis (revised for slow accrual) was that stent-assisted coiling would decrease treatment failures from 33% to 15%, requiring 200 patients. Primary analyses were intent to treat. RESULTS: Of 205 patients recruited between 2011 and 2021, ninety-four were allocated to stent-assisted coiling and 111 to coiling alone. The primary outcome, ascertainable in 203 patients, was reached in 28/93 patients allocated to stent-assisted coiling (30.1%; 95% CI, 21.2%–40.6%) compared with 30/110 (27.3%; 95% CI, 19.4%–36.7%) allocated to coiling alone (relative risk = 1.10; 95% CI, 0.7–1.7; P = .66). Poor clinical outcomes (mRS >2) occurred in 8/94 patients allocated to stent-assisted coiling (8.5%; 95% CI, 4.0%–16.6%) compared with 6/111 (5.4%; 95% CI, 2.2%–11.9%) allocated to coiling alone (relative risk = 1.6; 95% CI, 0.6%–4.4%; P = .38). CONCLUSIONS: The STAT trial did not show stent-assisted coiling to be superior to coiling alone for wide-neck, large, or recurrent unruptured aneurysms.
- Open Access
- 4 August 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (9) , 1244-1251
Flow Diversion in the Treatment of Intracranial Aneurysms: A Pragmatic Randomized Care Trial
BACKGROUND AND PURPOSE: Flow diversion is a recent endovascular treatment for intracranial aneurysms. We compared the safety and efficacy of flow diversion with the alternative standard management options. MATERIALS AND METHODS: A parallel group, prerandomized, controlled, open-label pragmatic trial was conducted in 3 Canadian centers. The trial included all patients considered for flow diversion. A Web-based platform 1:1 randomly allocated patients to flow diversion or 1 of 4 alternative standard management options (coiling with/without stent placement, parent vessel occlusion, surgical clipping, or observation) as prespecified by clinical judgment. Patients ineligible for alternative standard management options were treated with flow diversion in a registry. The primary safety outcome was death or dependency (mRS > 2) at 3 months. The composite primary efficacy outcome included the core lab–determined angiographic presence of a residual aneurysm, aneurysm rupture, progressive mass effect during follow-up, or death or dependency (mRS > 2) at 3–12 months. RESULTS: Between May 2011 and November 2020, three hundred twenty-three patients were recruited: Two hundred seventy-eight patients (86%) had treatment randomly allocated (139 to flow diversion and 139 to alternative standard management options), and 45 (14%) received flow diversion in the registry. Patients in the randomized trial frequently had unruptured (83%), large (52% ≥10 mm) carotid (64%) aneurysms. Death or dependency at 3 months occurred in 16/138 patients who underwent flow diversion and 12/137 patients receiving alternative standard management options (relative risk, 1.33; 95% CI, 0.65–2.69; P = .439). A poor primary efficacy outcome was found in 30.9% (43/139) with flow diversion and 45.6% (62/136) of patients receiving alternative standard management options, with an absolute risk difference of 14.7% (95% CI, 3.3%–26.0%; relative risk, 0.68; 95% CI, 0.50–0.92; P = .014). CONCLUSIONS: For patients with mostly unruptured, large, anterior circulation (carotid) aneurysms, flow diversion was more effective than the alternative standard management option in terms of angiographic outcome.
- 4 August 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (9) , 1244-1251
Open AccessFlow Diversion in the Treatment of Intracranial Aneurysms: A Pragmatic Randomized Care Trial
BACKGROUND AND PURPOSE: Flow diversion is a recent endovascular treatment for intracranial aneurysms. We compared the safety and efficacy of flow diversion with the alternative standard management options. MATERIALS AND METHODS: A parallel group, prerandomized, controlled, open-label pragmatic trial was conducted in 3 Canadian centers. The trial included all patients considered for flow diversion. A Web-based platform 1:1 randomly allocated patients to flow diversion or 1 of 4 alternative standard management options (coiling with/without stent placement, parent vessel occlusion, surgical clipping, or observation) as prespecified by clinical judgment. Patients ineligible for alternative standard management options were treated with flow diversion in a registry. The primary safety outcome was death or dependency (mRS > 2) at 3 months. The composite primary efficacy outcome included the core lab–determined angiographic presence of a residual aneurysm, aneurysm rupture, progressive mass effect during follow-up, or death or dependency (mRS > 2) at 3–12 months. RESULTS: Between May 2011 and November 2020, three hundred twenty-three patients were recruited: Two hundred seventy-eight patients (86%) had treatment randomly allocated (139 to flow diversion and 139 to alternative standard management options), and 45 (14%) received flow diversion in the registry. Patients in the randomized trial frequently had unruptured (83%), large (52% ≥10 mm) carotid (64%) aneurysms. Death or dependency at 3 months occurred in 16/138 patients who underwent flow diversion and 12/137 patients receiving alternative standard management options (relative risk, 1.33; 95% CI, 0.65–2.69; P = .439). A poor primary efficacy outcome was found in 30.9% (43/139) with flow diversion and 45.6% (62/136) of patients receiving alternative standard management options, with an absolute risk difference of 14.7% (95% CI, 3.3%–26.0%; relative risk, 0.68; 95% CI, 0.50–0.92; P = .014). CONCLUSIONS: For patients with mostly unruptured, large, anterior circulation (carotid) aneurysms, flow diversion was more effective than the alternative standard management option in terms of angiographic outcome.
- Open Access
- 3 February 2022
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 29 (2) , 134-140
Long term safety and effectiveness of LVIS Jr for treatment of intracranial aneurysms- a Canadian Multicenter registry
Background: The Low-profile Visible Intraluminal Support device (LVIS Jr) has become a commonly used intracranial stent for the treatment of intracranial aneurysms. However long-term stability and effectiveness remains to be seen. The purpose of the study was to assess the long-term efficacy, safety and durability of LVIS Jr. in a retrospective multicenter registry. Methods: Patients with saccular aneurysms treated at centers across Canada using LVIS Jr for intracranial aneurysms were included in this retrospective registry between the dates of January 2013 and April 2019. Self reported outcomes were collected and used to assess both perioperative and long term safety and effectiveness. Both univariate and multivariate analysis were performed. Results: Total of 196 patients (132 Women; mean age of 57.6 years) underwent endovascular aneurysm treatment with at least 1 LVIS Jr. stent. Mean aneurysm dome size was 7.4 mm, and mean neck size of 4.3 mm. Mean clinical and imaging follow up were 950 and 899 days respectively. Class I/II was achieved in 85% on long term follow up. Periprocedural morbidity and mortality was 4.6% and 2% and additional delayed morbidity and mortality was 3% and 2.5%. Aneurysm size >10 mm was independent predictor of periprocedural complication (OR 2.59, p = 0.048) while an increased dome to neck ratio >1.5 was independent predictor of increased delayed complications (OR 3.99, p = 0.02). Conclusion: The LVIS Jr. intracranial stent is an effective device in the treatment of intracranial aneurysms. Satisfactory long term occlusion rates can be achieved safely with stent-assisted coil embolization.
- 3 February 2022
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 29 (2) , 134-140
Open AccessLong term safety and effectiveness of LVIS Jr for treatment of intracranial aneurysms- a Canadian Multicenter registry
Background: The Low-profile Visible Intraluminal Support device (LVIS Jr) has become a commonly used intracranial stent for the treatment of intracranial aneurysms. However long-term stability and effectiveness remains to be seen. The purpose of the study was to assess the long-term efficacy, safety and durability of LVIS Jr. in a retrospective multicenter registry. Methods: Patients with saccular aneurysms treated at centers across Canada using LVIS Jr for intracranial aneurysms were included in this retrospective registry between the dates of January 2013 and April 2019. Self reported outcomes were collected and used to assess both perioperative and long term safety and effectiveness. Both univariate and multivariate analysis were performed. Results: Total of 196 patients (132 Women; mean age of 57.6 years) underwent endovascular aneurysm treatment with at least 1 LVIS Jr. stent. Mean aneurysm dome size was 7.4 mm, and mean neck size of 4.3 mm. Mean clinical and imaging follow up were 950 and 899 days respectively. Class I/II was achieved in 85% on long term follow up. Periprocedural morbidity and mortality was 4.6% and 2% and additional delayed morbidity and mortality was 3% and 2.5%. Aneurysm size >10 mm was independent predictor of periprocedural complication (OR 2.59, p = 0.048) while an increased dome to neck ratio >1.5 was independent predictor of increased delayed complications (OR 3.99, p = 0.02). Conclusion: The LVIS Jr. intracranial stent is an effective device in the treatment of intracranial aneurysms. Satisfactory long term occlusion rates can be achieved safely with stent-assisted coil embolization.