Water and fat separation in real‐time MRI of joint movement with phase‐sensitive bSSFP
- 15 July 2016
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (1) , 58-68
Abstract
Purpose: To introduce a method for obtaining fat‐suppressed images in real‐time MRI of moving joints at 3 Tesla (T) using a bSSFP sequence with phase detection to enhance visualization of soft tissue structures during motion.Methods: The wrist and knee of nine volunteers were imaged with a real‐time bSSFP sequence while performing dynamic tasks. For appropriate choice of sequence timing parameters, water and fat pixels showed an out‐of‐phase behavior, which was exploited to reconstruct water and fat images. Additionally, a 2‐point Dixon sequence was used for dynamic imaging of the joints, and resulting water and fat images were compared with our proposed method.Results: The joints could be visualized with good water–fat separation and signal‐to‐noise ratio (SNR), while maintaining a relatively high temporal resolution (5 fps in knee imaging and 10 fps in wrist imaging). The proposed method produced images of moving joints with higher SNR and higher image quality when compared with the Dixon method.Conclusions: Water–fat separation is feasible in real‐time MRI of moving knee and wrist at 3 T. PS‐bSSFP offers movies with higher SNR and higher diagnostic quality when compared with Dixon scans. Magn Reson Med 78:58–68, 2017. © 2016 International Society for Magnetic Resonance in MedicineKeywords
This publication has 30 references indexed in Scilit:
- Real-Time Magnetic Resonance Imaging (MRI) during Active Wrist Motion—Initial ObservationsPLOS ONE, 2013
- In vivo patellofemoral contact mechanics during active extension using a novel dynamic MRI-based methodologyOsteoarthritis and Cartilage, 2013
- Rectus Femoris Knee Muscle Moment Arms Measured in Vivo During Dynamic Motion With Real-Time Magnetic Resonance ImagingJournal of Biomechanical Engineering, 2013
- Positive Contrast MR Imaging of Tendons, Ligaments, and Menisci by Subtraction of Signals From a Double Echo Steady State Sequence (Sub‐DESS)Magnetic Resonance in Medicine, 2013
- Do dynamic‐based MR knee kinematics methods produce the same results as static methods?Magnetic Resonance in Medicine, 2012
- Measurement of tibiofemoral kinematics using highly accelerated 3D radial samplingMagnetic Resonance in Medicine, 2012
- Differences in patellofemoral kinematics between weight‐bearing and non‐weight‐bearing conditions in patients with patellofemoral painJournal of Orthopaedic Research, 2010
- Using real‐time MRI to quantify altered joint kinematics in subjects with patellofemoral pain and to evaluate the effects of a patellar brace or sleeve on joint motionJournal of Orthopaedic Research, 2008
- Feasibility of using real‐time MRI to measure joint kinematics in 1.5T and open‐bore 0.5T systemsJournal of Magnetic Resonance Imaging, 2008
- Altered knee kinematics in ACL‐deficient non‐copers: A comparison using dynamic MRIJournal of Orthopaedic Research, 2005