Kinematics of the Normal Knee during Dynamic Activities: A Synthesis of Data from Intracortical Pins and Biplane Imaging
Open Access
- 11 April 2017
- journal article
- research article
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2017, 1-9
Abstract
Few studies have provided in vivo tibiofemoral kinematics of the normal knee during dynamic weight-bearing activities. Indeed, gold standard measurement methods (i.e., intracortical pins and biplane imaging) raise ethical and experimental issues. Moreover, the conventions used for the processing of the kinematics show large inconsistencies. This study aims at synthesising the tibiofemoral kinematics measured with gold standard measurement methods. Published kinematic data were transformed in the standard recommended by the International Society of Biomechanics (ISB), and a clustering method was applied to investigate whether the couplings between the degrees of freedom (DoFs) are consistent among the different activities and measurement methods. The synthesised couplings between the DoFs during knee flexion (from 4° of extension to −61° of flexion) included abduction (up to −10°); internal rotation (up to 15°); and medial (up to 10 mm), anterior (up to 25 mm), and proximal (up to 28 mm) displacements. These synthesised couplings appeared mainly partitioned into two clusters that featured all the dynamic weight-bearing activities and all the measurement methods. Thus, the effect of the dynamic activities on the couplings between the tibiofemoral DoFs appeared to be limited. The synthesised data might be used as a reference of normal in vivo knee kinematics for prosthetic and orthotic design and for knee biomechanical model development and validation.Keywords
This publication has 35 references indexed in Scilit:
- Can one angle be simply subtracted from another to determine range of motion in three-dimensional motion analysis?Computer Methods in Biomechanics and Biomedical Engineering, 2012
- Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray studyClinical Biomechanics, 2012
- Kinematic evaluation of the step-up exercise in anterior cruciate ligament deficiencyClinical Biomechanics, 2011
- In Vivo Tibiofemoral Kinematics During 4 Functional Tasks of Increasing Demand Using Biplane FluoroscopyThe American Journal of Sports Medicine, 2011
- Tibiofemoral kinematics and condylar motion during the stance phase of gaitJournal of Biomechanics, 2009
- New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gaitJournal of Orthopaedic Surgery and Research, 2009
- Thrombin related peptide TP508 promoted fracture repair in a mouse high energy fracture modelJournal of Orthopaedic Surgery and Research, 2009
- The movement of the normal tibio-femoral jointJournal of Biomechanics, 2005
- ISB recommendations for standardization in the reporting of kinematic dataJournal of Biomechanics, 1995
- Three-dimensional kinematics of the human knee during walkingJournal of Biomechanics, 1992