Yoann Lafon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoann Lafon has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Raphaël Dumas
Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T 9406, F-69622 Lyon, France
5 shared publications - Virginie Lafage
Department of Orthopaedics, Lenox Hill Hospital, Northwell Health, New York, New York, USA
3 shared publications Wafa Skalli
3 shared publications- Alejandra Polanco
Pontificia Universidad Javeriana, Bogotá, Colombia
2 shared publications E. Ebermeyer
CHU Hop Bellevue, Unite Rachis, St Etienne, France
2 shared publications- Georges Beurier
Univ. Lyon, Univ. Gustave Eiffel
2 shared publications
Latest Publications
- 1 October 2025
- Published by Springer Nature
- p. 287-294
Creation of a Personalized Digital Human Model from External Skin Surface and Its Repositioning
- 1 October 2025
- Published by Springer Nature
- p. 287-294
Creation of a Personalized Digital Human Model from External Skin Surface and Its Repositioning
- 19 July 2023
- Published by Springer Nature
- p. 168-176
A Workflow for Deforming External Body Shapes with the Help of an Anatomically Correct Skeletal Model
- 19 July 2023
- Published by Springer Nature
- p. 168-176
A Workflow for Deforming External Body Shapes with the Help of an Anatomically Correct Skeletal Model
- 27 June 2023
- Published by SAE International in Stapp Car Crash Journal
- Vol. 66 (1) , 69-97
Ligaments Laxity and Elongation at Injury in Flexed knees during Lateral Impact Conditions
The knee is one of the regions of interest for pedestrian safety assessment. Past testing to study knee ligament injuries for pedestrian impact only included knees in full extension and mostly focused on global responses. As the knee flexion angle and the initial ligament laxity may affect the elongation at which ligaments fail, the objectives of this study were (1) to design an experimental protocol to assess the laxity of knee ligaments before measuring their elongation at failure, (2) to apply it in paired knee tests at two flexion angles (10 and 45 degrees). The laxity tests combined strain gauges to measure bone strains near insertions that would result from ligament forces and a custom machine to exercise the knee in all directions. Failure was assessed using a four-point bending setup with additional degrees of freedom on the axial rotation and displacement of the femur. A template was designed to ensure that the two setups used the exact same starting position. The protocol was applied to six pairs of knees which were tested until the failure of all ligaments. In the laxity tests, a higher compliance of the knee was observed at 45 degrees compared to 10 degrees. Minimum lengths associated with the beginning of bone loading were also successfully identified for the collateral ligaments, but the process was less successful for the cruciate ligaments. The failure tests suggested increased elongation and length at failure for the ligaments and their bundles at 45°. This could be consistent with the higher compliance in static test, but the minimum lengths identified on the collaterals did not explain this difference during failure. The results highlight the possible relationship between position, laxity and elongation at failure in a lateral loading and provide a dataset including 3D coordinates of insertions to continue the investigation using a modelling approach. Perspectives are also outlined to improve upon the laxity determination protocol.
- 27 June 2023
- Published by SAE International in Stapp Car Crash Journal
- Vol. 66 (1) , 69-97
Ligaments Laxity and Elongation at Injury in Flexed knees during Lateral Impact Conditions
The knee is one of the regions of interest for pedestrian safety assessment. Past testing to study knee ligament injuries for pedestrian impact only included knees in full extension and mostly focused on global responses. As the knee flexion angle and the initial ligament laxity may affect the elongation at which ligaments fail, the objectives of this study were (1) to design an experimental protocol to assess the laxity of knee ligaments before measuring their elongation at failure, (2) to apply it in paired knee tests at two flexion angles (10 and 45 degrees). The laxity tests combined strain gauges to measure bone strains near insertions that would result from ligament forces and a custom machine to exercise the knee in all directions. Failure was assessed using a four-point bending setup with additional degrees of freedom on the axial rotation and displacement of the femur. A template was designed to ensure that the two setups used the exact same starting position. The protocol was applied to six pairs of knees which were tested until the failure of all ligaments. In the laxity tests, a higher compliance of the knee was observed at 45 degrees compared to 10 degrees. Minimum lengths associated with the beginning of bone loading were also successfully identified for the collateral ligaments, but the process was less successful for the cruciate ligaments. The failure tests suggested increased elongation and length at failure for the ligaments and their bundles at 45°. This could be consistent with the higher compliance in static test, but the minimum lengths identified on the collaterals did not explain this difference during failure. The results highlight the possible relationship between position, laxity and elongation at failure in a lateral loading and provide a dataset including 3D coordinates of insertions to continue the investigation using a modelling approach. Perspectives are also outlined to improve upon the laxity determination protocol.
- Open Access
- 17 January 2022
- Published by Elsevier in Veterinary and Animal Science
- Vol. 15, 100233
A morphometric analysis of thoracolumbar vertebrae in goat by computed tomography.
- 17 January 2022
- Published by Elsevier in Veterinary and Animal Science
- Vol. 15, 100233
Open AccessA morphometric analysis of thoracolumbar vertebrae in goat by computed tomography.
- 12 November 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (2)
A Method to Use Kriging With Large Sets of Control Points to Morph Finite Element Models of the Human Body
As developing finite element (FE) human body models for automotive impact is a time-consuming process, morphing using interpolation methods such as kriging has often been used to rapidly generate models of different shapes and sizes. Kriging can be computationally expensive when many control points (CPs) are used, i.e., for very detailed target geometry (e.g., shape of bones and skin). It can also lead to element quality issues (up to inverted elements) preventing the use of the morphed models for finite element simulation. This paper presents a workflow combining iterative subsampling and spatial subdivision methodology that effectively reduces the computational costs and allows for the generation of usable models through kriging with hundreds of thousands of control points. As subdivision introduces discontinuities in the interpolation function that can cause distortion of elements on the boundaries of individual subdivision areas, algorithms for smoothing the interpolation over those boundaries are proposed and compared. Those techniques and their combinations were tested and evaluated in a scenario of mass change on the detailed 50th percentile male model of the global human body models consortium (GHBMC): the model, which has body mass index (BMI) 25.34, was morphed toward a statistical surface model of a person with body mass index 20, 22.7 and 35. 234 777 control points were used to successfully morph the model in less than 15 min on an office PC. Open source implementation is provided.
- 12 November 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (2)
A Method to Use Kriging With Large Sets of Control Points to Morph Finite Element Models of the Human Body
As developing finite element (FE) human body models for automotive impact is a time-consuming process, morphing using interpolation methods such as kriging has often been used to rapidly generate models of different shapes and sizes. Kriging can be computationally expensive when many control points (CPs) are used, i.e., for very detailed target geometry (e.g., shape of bones and skin). It can also lead to element quality issues (up to inverted elements) preventing the use of the morphed models for finite element simulation. This paper presents a workflow combining iterative subsampling and spatial subdivision methodology that effectively reduces the computational costs and allows for the generation of usable models through kriging with hundreds of thousands of control points. As subdivision introduces discontinuities in the interpolation function that can cause distortion of elements on the boundaries of individual subdivision areas, algorithms for smoothing the interpolation over those boundaries are proposed and compared. Those techniques and their combinations were tested and evaluated in a scenario of mass change on the detailed 50th percentile male model of the global human body models consortium (GHBMC): the model, which has body mass index (BMI) 25.34, was morphed toward a statistical surface model of a person with body mass index 20, 22.7 and 35. 234 777 control points were used to successfully morph the model in less than 15 min on an office PC. Open source implementation is provided.
- Open Access
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S434-S435
Influence of implant and screw type on local bone strain field: a preliminary study
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S434-S435
Open AccessInfluence of implant and screw type on local bone strain field: a preliminary study
- Open Access
- 11 April 2017
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2017, 1-9
Kinematics of the Normal Knee during Dynamic Activities: A Synthesis of Data from Intracortical Pins and Biplane Imaging
Few studies have provided in vivo tibiofemoral kinematics of the normal knee during dynamic weight-bearing activities. Indeed, gold standard measurement methods (i.e., intracortical pins and biplane imaging) raise ethical and experimental issues. Moreover, the conventions used for the processing of the kinematics show large inconsistencies. This study aims at synthesising the tibiofemoral kinematics measured with gold standard measurement methods. Published kinematic data were transformed in the standard recommended by the International Society of Biomechanics (ISB), and a clustering method was applied to investigate whether the couplings between the degrees of freedom (DoFs) are consistent among the different activities and measurement methods. The synthesised couplings between the DoFs during knee flexion (from 4° of extension to −61° of flexion) included abduction (up to −10°); internal rotation (up to 15°); and medial (up to 10 mm), anterior (up to 25 mm), and proximal (up to 28 mm) displacements. These synthesised couplings appeared mainly partitioned into two clusters that featured all the dynamic weight-bearing activities and all the measurement methods. Thus, the effect of the dynamic activities on the couplings between the tibiofemoral DoFs appeared to be limited. The synthesised data might be used as a reference of normal in vivo knee kinematics for prosthetic and orthotic design and for knee biomechanical model development and validation.
- 11 April 2017
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2017, 1-9
Open AccessKinematics of the Normal Knee during Dynamic Activities: A Synthesis of Data from Intracortical Pins and Biplane Imaging
Few studies have provided in vivo tibiofemoral kinematics of the normal knee during dynamic weight-bearing activities. Indeed, gold standard measurement methods (i.e., intracortical pins and biplane imaging) raise ethical and experimental issues. Moreover, the conventions used for the processing of the kinematics show large inconsistencies. This study aims at synthesising the tibiofemoral kinematics measured with gold standard measurement methods. Published kinematic data were transformed in the standard recommended by the International Society of Biomechanics (ISB), and a clustering method was applied to investigate whether the couplings between the degrees of freedom (DoFs) are consistent among the different activities and measurement methods. The synthesised couplings between the DoFs during knee flexion (from 4° of extension to −61° of flexion) included abduction (up to −10°); internal rotation (up to 15°); and medial (up to 10 mm), anterior (up to 25 mm), and proximal (up to 28 mm) displacements. These synthesised couplings appeared mainly partitioned into two clusters that featured all the dynamic weight-bearing activities and all the measurement methods. Thus, the effect of the dynamic activities on the couplings between the tibiofemoral DoFs appeared to be limited. The synthesised data might be used as a reference of normal in vivo knee kinematics for prosthetic and orthotic design and for knee biomechanical model development and validation.
- 9 November 2015
- Published by SAE International in Stapp Car Crash Journal
- Vol. 59, 337-57
Comparison of Kriging and Moving Least Square Methods to Change the Geometry of Human Body Models
Finite Element Human Body Models (HBM) have become powerful tools to study the response to impact. However, they are typically only developed for a limited number of sizes and ages. Various approaches driven by control points have been reported in the literature for the non-linear scaling of these HBM into models with different geometrical characteristics. The purpose of this study is to compare the performances of commonly used control points based interpolation methods in different usage scenarios. Performance metrics include the respect of target, the mesh quality and the runability. For this study, the Kriging and Moving Least square interpolation approaches were compared in three test cases. The first two cases correspond to changes of anthropometric dimensions of (1) a child model (from 6 to 1.5 years old) and (2) the GHBMC M50 model (Global Human Body Models Consortium, from 50th to 5th percentile female). For the third case, the GHBMC M50 ribcage was scaled to match the rib cage geometry derived from a CT-scan. In the first two test cases, all tested methods provided similar shapes with acceptable results in terms of time needed for the deformation (a few minutes at most), overall respect of the targets, element quality distribution and time step for explicit simulation. The personalization of rib cage proved to be much more challenging. None of the methods tested provided fully satisfactory results at the level of the rib trajectory and section. There were corrugated local deformations unless using a smooth regression through relaxation. Overall, the results highlight the importance of the target definition over the interpolation method.
- 9 November 2015
- Published by SAE International in Stapp Car Crash Journal
- Vol. 59, 337-57
Comparison of Kriging and Moving Least Square Methods to Change the Geometry of Human Body Models
Finite Element Human Body Models (HBM) have become powerful tools to study the response to impact. However, they are typically only developed for a limited number of sizes and ages. Various approaches driven by control points have been reported in the literature for the non-linear scaling of these HBM into models with different geometrical characteristics. The purpose of this study is to compare the performances of commonly used control points based interpolation methods in different usage scenarios. Performance metrics include the respect of target, the mesh quality and the runability. For this study, the Kriging and Moving Least square interpolation approaches were compared in three test cases. The first two cases correspond to changes of anthropometric dimensions of (1) a child model (from 6 to 1.5 years old) and (2) the GHBMC M50 model (Global Human Body Models Consortium, from 50th to 5th percentile female). For the third case, the GHBMC M50 ribcage was scaled to match the rib cage geometry derived from a CT-scan. In the first two test cases, all tested methods provided similar shapes with acceptable results in terms of time needed for the deformation (a few minutes at most), overall respect of the targets, element quality distribution and time step for explicit simulation. The personalization of rib cage proved to be much more challenging. None of the methods tested provided fully satisfactory results at the level of the rib trajectory and section. There were corrugated local deformations unless using a smooth regression through relaxation. Overall, the results highlight the importance of the target definition over the interpolation method.