FLIM and FCS detection in laser‐scanning microscopes: Increased efficiency by GaAsP hybrid detectors
Authors:
- 3 December 2010
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 74 (9) , 804-811
Abstract
Photon counting detectors currently used in fluorescence lifetime microscopy have a number of deficiencies that result in less‐than‐ideal signal‐to‐noise ratio of the lifetimes obtained: Either the quantum efficiency is unsatisfactory or the active area is too small, and afterpulsing or tails in the temporal response contribute to overall timing inaccuracy. We have therefore developed a new FLIM detector based on a GaAsP hybrid photomultiplier. Compared with conventional PMTs and SPADs, GaAsP hybrid detectors have a number of advantages: The detection quantum efficiency reaches or surpasses the efficiency of fast SPADs, and the active area is on the order of 5 mm2, compared with 2.5 10−3 mm2 for a SPAD. The TCSPC response is clean, without the bumps and the diffusion tails typical for PMTs and SPADs. Most important, the hybrid detector is intrinsically free of afterpulsing. FLIM results are therefore free of signal‐dependent background, and FCS curves are free of the known afterpulsing peak. We demonstrate the performance of the new detector for multiphoton NDD FLIM and for FCS. Microsc. Res. Tech., 2011.Keywords
This publication has 23 references indexed in Scilit:
- Clinical multiphoton tomographyJournal of Biophotonics, 2008
- Prolonged irradiation of enhanced cyan fluorescent protein or Cerulean can invalidate Förster resonance energy transfer measurementsJournal of Biomedical Optics, 2008
- Multispectral fluorescence lifetime imaging by TCSPCMicroscopy Research and Technique, 2007
- Towards metabolic mapping of the human retinaMicroscopy Research and Technique, 2007
- In vivo multiphoton fluorescence lifetime imaging of protein-bound and free nicotinamide adenine dinucleotide in normal and precancerous epitheliaJournal of Biomedical Optics, 2007
- Chloride Accumulation in Mammalian Olfactory Sensory NeuronsThe Journal of Neuroscience, 2004
- Interaction of PSD-95 with potassium channels visualized by fluorescence lifetime-based resonance energy transfer imagingJournal of Biomedical Optics, 2004
- Photon counting III-V hybrid photomultipliers using transmission mode photocathodesIEEE Transactions on Electron Devices, 1997
- An error analysis of the rapid lifetime determination method for the evaluation of single exponential decaysAnalytical Chemistry, 1989
- The origins of afterpulses in photomultipliersJournal of Physics D: Applied Physics, 1973