Wolfgang Becker
Research Subjects
Wolfgang Becker has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Axel Bergmann
Becker & Hickl, Nahmitzer Damm 30, 12277 Berlin, Germany
3 shared publications- Christoph Biskup
Friedrich-Schiller Univ. Jena (Germany)
2 shared publications - Marina V. Shirmanova
Institute of Experimental Oncology and Biomedical Technologies, Privolzhsky Research Medical University, 10/1 Minin and Pozharsky Sq., 603005 Nizhny Novgorod, Russia
2 shared publications - Vladislav I. Shcheslavskiy
Privolzhsky Research Medical University
2 shared publications - Alexandra Arkhipchenko
Lomonosov Moscow State University
1 shared publication - Alexey A. Kostyukov
N. M. Emanuel Institute of Biochemical Physics, Russian Academy of Sciences, 119334 Moscow, Russia
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (06) , 1-11
Spectral dependence of lipofuscin fluorescence lifetimes revealed by FLIM with a superconducting nanowire single-photon detector
SignificanceThe noninvasive assessment of oxidative stress in the retinal pigment epithelium (RPE), a key factor in the pathogenesis of age-related macular degeneration (AMD), is an important aspect in ophthalmic diagnostics. Although fundus autofluorescence (FAF) is clinically used, its diagnostic power is limited. Fluorescence lifetime imaging ophthalmoscopy shows promise, but the photophysical underpinnings of lifetime changes in lipofuscin—the dominant RPE fluorophore—remain poorly understood. Lipofuscin granules (LGs) in the RPE are a primary source of fundus autofluorescence and are critically involved in the pathogenesis of AMD. This study characterizes the spectral and lifetime properties of LGs using a fluorescence lifetime imaging microscopy (FLIM) system integrated with a wide-range sensitivity, large-active-area superconducting nanowire single-photon detector (SNSPD) coupled with a standard 50 μm multimode fiber.AimWe present experiments on multispectral fluorescence lifetime imaging with a detailed analysis of the fluorescence decays and spectral profiles of LGs in the RPE cells to probe the molecular oxidative state of RPE lipofuscin, aiming to improve AMD understanding and propose a method for early diagnosis of retinal pathologies.ApproachWe use a cutting-edge FLIM system integrated via a multimode fiber with a large-active-area SNSPD. Unlike previous studies, our approach provides component-resolved and spatially resolved fluorescence decay kinetics across a broad spectral range (500 to 1000 nm), which is typically inaccessible to conventional detectors. LGs were isolated from 100 human (aged 50 to 75 years) donor RPE cells and subjected to in vitro photo-oxidation to simulate AMD-like conditions. Steady-state spectroscopy revealed a blue shift in emission following photo-oxidation.ResultsFLIM analysis, employing a tri-exponential decay model, showed a significant increase in the mean fluorescence lifetime τm from ∼247 to ∼587 ps after photo-oxidation. Crucially, we identified a pronounced direct spectral dependence of fluorescence lifetimes τm versus wavelength: for native LGs, τm increased from 136 to 319 ps at registration range 500 to 650 nm; for photo-oxidized LGs, it increased from 174 to 623 ps over the same region. High-performance liquid chromatography confirmed the degradation of the bisretinoid A2E and accumulation of oxidized derivatives, correlating with the observed photophysical changes.ConclusionsThese findings demonstrate that component-resolved visible-near infrared spectral FLIM provides a sensitive, noninvasive approach to probe the molecular oxidative state of RPE lipofuscin, offering potential for early diagnosis of retinal pathologies.
- 1 June 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (06) , 1-11
Open AccessSpectral dependence of lipofuscin fluorescence lifetimes revealed by FLIM with a superconducting nanowire single-photon detector
SignificanceThe noninvasive assessment of oxidative stress in the retinal pigment epithelium (RPE), a key factor in the pathogenesis of age-related macular degeneration (AMD), is an important aspect in ophthalmic diagnostics. Although fundus autofluorescence (FAF) is clinically used, its diagnostic power is limited. Fluorescence lifetime imaging ophthalmoscopy shows promise, but the photophysical underpinnings of lifetime changes in lipofuscin—the dominant RPE fluorophore—remain poorly understood. Lipofuscin granules (LGs) in the RPE are a primary source of fundus autofluorescence and are critically involved in the pathogenesis of AMD. This study characterizes the spectral and lifetime properties of LGs using a fluorescence lifetime imaging microscopy (FLIM) system integrated with a wide-range sensitivity, large-active-area superconducting nanowire single-photon detector (SNSPD) coupled with a standard 50 μm multimode fiber.AimWe present experiments on multispectral fluorescence lifetime imaging with a detailed analysis of the fluorescence decays and spectral profiles of LGs in the RPE cells to probe the molecular oxidative state of RPE lipofuscin, aiming to improve AMD understanding and propose a method for early diagnosis of retinal pathologies.ApproachWe use a cutting-edge FLIM system integrated via a multimode fiber with a large-active-area SNSPD. Unlike previous studies, our approach provides component-resolved and spatially resolved fluorescence decay kinetics across a broad spectral range (500 to 1000 nm), which is typically inaccessible to conventional detectors. LGs were isolated from 100 human (aged 50 to 75 years) donor RPE cells and subjected to in vitro photo-oxidation to simulate AMD-like conditions. Steady-state spectroscopy revealed a blue shift in emission following photo-oxidation.ResultsFLIM analysis, employing a tri-exponential decay model, showed a significant increase in the mean fluorescence lifetime τm from ∼247 to ∼587 ps after photo-oxidation. Crucially, we identified a pronounced direct spectral dependence of fluorescence lifetimes τm versus wavelength: for native LGs, τm increased from 136 to 319 ps at registration range 500 to 650 nm; for photo-oxidized LGs, it increased from 174 to 623 ps over the same region. High-performance liquid chromatography confirmed the degradation of the bisretinoid A2E and accumulation of oxidized derivatives, correlating with the observed photophysical changes.ConclusionsThese findings demonstrate that component-resolved visible-near infrared spectral FLIM provides a sensitive, noninvasive approach to probe the molecular oxidative state of RPE lipofuscin, offering potential for early diagnosis of retinal pathologies.
- Open Access
- 30 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (10) , 106501-14
Simultaneous assessment of NAD(P)H and flavins with multispectral fluorescence lifetime imaging microscopy at a single excitation wavelength of 750 nm
SignificanceAutofluorescence characteristics of the reduced nicotinamide adenine dinucleotide and oxidized flavin cofactors are important for the evaluation of the metabolic status of the cells. The approaches that involve a detailed analysis of both spectral and time characteristics of the autofluorescence signals may provide additional insights into the biochemical processes in the cells and biological tissues and facilitate the transition of spectral fluorescence lifetime imaging into clinical applications.AimWe present the experiments on multispectral fluorescence lifetime imaging with a detailed analysis of the fluorescence decays and spectral profiles of the reduced nicotinamide adenine dinucleotide and oxidized flavin under a single excitation wavelength aimed at understanding whether the use of multispectral detection is helpful for metabolic imaging of cancer cells.ApproachWe use two-photon spectral fluorescence lifetime imaging microscopy. Starting from model solutions, we switched to cell cultures treated by metabolic inhibitors and then studied the metabolism of cells within tumor spheroids.ResultsThe use of a multispectral detector in combination with an excitation at a single wavelength of 750 nm allows the identification of fluorescence signals from three components: free and bound NAD(P)H, and flavins based on the global fitting procedure. Multispectral data make it possible to assess not only the lifetime but also the spectral shifts of emission of flavins caused by chemical perturbations. Altogether, the informative parameters of the developed approach are the ratio of free and bound NAD(P)H amplitudes, the decay time of bound NAD(P)H, the amplitude of flavin fluorescence signal, the fluorescence decay time of flavins, and the spectral shift of the emission signal of flavins. Hence, with multispectral fluorescence lifetime imaging, we get five independent parameters, of which three are related to flavins.ConclusionsThe approach to probe the metabolic state of cells in culture and spheroids using excitation at a single wavelength of 750 nm and a fluorescence time-resolved spectral detection with the consequent global analysis of the data not only simplifies image acquisition protocol but also allows to disentangle the impacts of free and bound NAD(P)H, and flavin components evaluate changes in their fluorescence parameters (emission spectra and fluorescence lifetime) upon treating cells with metabolic inhibitors and sense metabolic heterogeneity within 3D tumor spheroids.
- 30 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (10) , 106501-14
Open AccessSimultaneous assessment of NAD(P)H and flavins with multispectral fluorescence lifetime imaging microscopy at a single excitation wavelength of 750 nm
SignificanceAutofluorescence characteristics of the reduced nicotinamide adenine dinucleotide and oxidized flavin cofactors are important for the evaluation of the metabolic status of the cells. The approaches that involve a detailed analysis of both spectral and time characteristics of the autofluorescence signals may provide additional insights into the biochemical processes in the cells and biological tissues and facilitate the transition of spectral fluorescence lifetime imaging into clinical applications.AimWe present the experiments on multispectral fluorescence lifetime imaging with a detailed analysis of the fluorescence decays and spectral profiles of the reduced nicotinamide adenine dinucleotide and oxidized flavin under a single excitation wavelength aimed at understanding whether the use of multispectral detection is helpful for metabolic imaging of cancer cells.ApproachWe use two-photon spectral fluorescence lifetime imaging microscopy. Starting from model solutions, we switched to cell cultures treated by metabolic inhibitors and then studied the metabolism of cells within tumor spheroids.ResultsThe use of a multispectral detector in combination with an excitation at a single wavelength of 750 nm allows the identification of fluorescence signals from three components: free and bound NAD(P)H, and flavins based on the global fitting procedure. Multispectral data make it possible to assess not only the lifetime but also the spectral shifts of emission of flavins caused by chemical perturbations. Altogether, the informative parameters of the developed approach are the ratio of free and bound NAD(P)H amplitudes, the decay time of bound NAD(P)H, the amplitude of flavin fluorescence signal, the fluorescence decay time of flavins, and the spectral shift of the emission signal of flavins. Hence, with multispectral fluorescence lifetime imaging, we get five independent parameters, of which three are related to flavins.ConclusionsThe approach to probe the metabolic state of cells in culture and spheroids using excitation at a single wavelength of 750 nm and a fluorescence time-resolved spectral detection with the consequent global analysis of the data not only simplifies image acquisition protocol but also allows to disentangle the impacts of free and bound NAD(P)H, and flavin components evaluate changes in their fluorescence parameters (emission spectra and fluorescence lifetime) upon treating cells with metabolic inhibitors and sense metabolic heterogeneity within 3D tumor spheroids.
- 28 October 2017
- Published by Springer Nature
- Vol. 1035, 19-30
Simultaneous Phosphorescence and Fluorescence Lifetime Imaging by Multi-Dimensional TCSPC and Multi-Pulse Excitation
TCSPC FLIM/PLIM is based on a multi-dimensional time-correlated single-photon counting process. The sample is scanned by a high-frequency-pulsed laser beam which is additionally modulated on/off synchronously with the pixels of the scan. FLIM is obtained by building up the distribution of the photons over the scanning coordinates and the times of the photons in the excitation pulse sequence, PLIM is obtained by building up the photon distribution over the scanning coordinates and the photon times in the modulation period. FLIM and PLIM data are thus obtained simultaneously within the same imaging process. Since the technique uses not only one but many excitation pulses for every phosphorescence signal period the sensitivity is much higher than for techniques that excite with a single pulse only. TCSPC FLIM/PLIM works both with one-photon and two-photon excitation, does not require a reduction of the laser pulse repetition rate by a pulse picker, and eliminates the need of high pulse energy for phosphorescence excitation.
- 28 October 2017
- Published by Springer Nature
- Vol. 1035, 19-30
Simultaneous Phosphorescence and Fluorescence Lifetime Imaging by Multi-Dimensional TCSPC and Multi-Pulse Excitation
TCSPC FLIM/PLIM is based on a multi-dimensional time-correlated single-photon counting process. The sample is scanned by a high-frequency-pulsed laser beam which is additionally modulated on/off synchronously with the pixels of the scan. FLIM is obtained by building up the distribution of the photons over the scanning coordinates and the times of the photons in the excitation pulse sequence, PLIM is obtained by building up the photon distribution over the scanning coordinates and the photon times in the modulation period. FLIM and PLIM data are thus obtained simultaneously within the same imaging process. Since the technique uses not only one but many excitation pulses for every phosphorescence signal period the sensitivity is much higher than for techniques that excite with a single pulse only. TCSPC FLIM/PLIM works both with one-photon and two-photon excitation, does not require a reduction of the laser pulse repetition rate by a pulse picker, and eliminates the need of high pulse energy for phosphorescence excitation.
- 13 January 2014
- Published by Wiley in Microscopy Research and Technique
- Vol. 77 (3) , 216-224
Spatially resolved recording of transient fluorescence-lifetime effects by line-scanning TCSPC
We present a technique that records transient changes in the fluorescence lifetime of a sample with spatial resolution along a one-dimensional scan. The technique is based on scanning the sample with a high-frequency pulsed laser beam, detecting single photons of the fluorescence light, and building up a photon distribution over the distance along the scan, the arrival times of the photons after the excitation pulses and the time after a stimulation of the sample. The maximum resolution at which lifetime changes can be recorded is given by the line scan period. Transient lifetime effects can thus be resolved at a resolution of about one millisecond. We demonstrate the technique for recording photochemical and nonphotochemical chlorophyll transients in plants and transient changes in free Ca2+ in cultured neurons. Microsc. Res. Tech. 77:216–224, 2014.
- 13 January 2014
- Published by Wiley in Microscopy Research and Technique
- Vol. 77 (3) , 216-224
Spatially resolved recording of transient fluorescence-lifetime effects by line-scanning TCSPC
We present a technique that records transient changes in the fluorescence lifetime of a sample with spatial resolution along a one-dimensional scan. The technique is based on scanning the sample with a high-frequency pulsed laser beam, detecting single photons of the fluorescence light, and building up a photon distribution over the distance along the scan, the arrival times of the photons after the excitation pulses and the time after a stimulation of the sample. The maximum resolution at which lifetime changes can be recorded is given by the line scan period. Transient lifetime effects can thus be resolved at a resolution of about one millisecond. We demonstrate the technique for recording photochemical and nonphotochemical chlorophyll transients in plants and transient changes in free Ca2+ in cultured neurons. Microsc. Res. Tech. 77:216–224, 2014.
- 3 December 2010
- Published by Wiley in Microscopy Research and Technique
- Vol. 74 (9) , 804-811
FLIM and FCS detection in laser‐scanning microscopes: Increased efficiency by GaAsP hybrid detectors
Photon counting detectors currently used in fluorescence lifetime microscopy have a number of deficiencies that result in less‐than‐ideal signal‐to‐noise ratio of the lifetimes obtained: Either the quantum efficiency is unsatisfactory or the active area is too small, and afterpulsing or tails in the temporal response contribute to overall timing inaccuracy. We have therefore developed a new FLIM detector based on a GaAsP hybrid photomultiplier. Compared with conventional PMTs and SPADs, GaAsP hybrid detectors have a number of advantages: The detection quantum efficiency reaches or surpasses the efficiency of fast SPADs, and the active area is on the order of 5 mm2, compared with 2.5 10−3 mm2 for a SPAD. The TCSPC response is clean, without the bumps and the diffusion tails typical for PMTs and SPADs. Most important, the hybrid detector is intrinsically free of afterpulsing. FLIM results are therefore free of signal‐dependent background, and FCS curves are free of the known afterpulsing peak. We demonstrate the performance of the new detector for multiphoton NDD FLIM and for FCS. Microsc. Res. Tech., 2011.
- 3 December 2010
- Published by Wiley in Microscopy Research and Technique
- Vol. 74 (9) , 804-811
FLIM and FCS detection in laser‐scanning microscopes: Increased efficiency by GaAsP hybrid detectors
Photon counting detectors currently used in fluorescence lifetime microscopy have a number of deficiencies that result in less‐than‐ideal signal‐to‐noise ratio of the lifetimes obtained: Either the quantum efficiency is unsatisfactory or the active area is too small, and afterpulsing or tails in the temporal response contribute to overall timing inaccuracy. We have therefore developed a new FLIM detector based on a GaAsP hybrid photomultiplier. Compared with conventional PMTs and SPADs, GaAsP hybrid detectors have a number of advantages: The detection quantum efficiency reaches or surpasses the efficiency of fast SPADs, and the active area is on the order of 5 mm2, compared with 2.5 10−3 mm2 for a SPAD. The TCSPC response is clean, without the bumps and the diffusion tails typical for PMTs and SPADs. Most important, the hybrid detector is intrinsically free of afterpulsing. FLIM results are therefore free of signal‐dependent background, and FCS curves are free of the known afterpulsing peak. We demonstrate the performance of the new detector for multiphoton NDD FLIM and for FCS. Microsc. Res. Tech., 2011.
- 28 March 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 70 (5) , 403-409
Multispectral fluorescence lifetime imaging by TCSPC
We present a fluorescence lifetime imaging technique with simultaneous spectral and temporal resolution. The technique is fully compatible with the commonly used multiphoton microscopes and nondescanned (direct) detection. An image of the back‐aperture of the microscope lens is projected on the input of a fiber bundle. The input of the fiber bundle is circular, and the output is flattened to match the input slit of a spectrograph. The spectrum at the output of the spectrograph is projected on a 16‐anode PMT module. For each detected photon, the encoding logics of the PMT module deliver a timing pulse and the number of the PMT channel in which the photon was detected. The photons are accumulated by a multidimensional time‐correlated single photon counting (TCSPC) process. The recording process builds up a four‐dimensional photon distribution over the times of the photons in the excitation pulse period, the wavelengths of the photons, and the coordinates of the scan area. The method delivers a near‐ideal counting efficiency and is capable of resolving double‐exponential decay functions. We demonstrate the performance of the technique for autofluorescence imaging of tissue. Microsc. Res. Tech., 2007.
- 28 March 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 70 (5) , 403-409
Multispectral fluorescence lifetime imaging by TCSPC
We present a fluorescence lifetime imaging technique with simultaneous spectral and temporal resolution. The technique is fully compatible with the commonly used multiphoton microscopes and nondescanned (direct) detection. An image of the back‐aperture of the microscope lens is projected on the input of a fiber bundle. The input of the fiber bundle is circular, and the output is flattened to match the input slit of a spectrograph. The spectrum at the output of the spectrograph is projected on a 16‐anode PMT module. For each detected photon, the encoding logics of the PMT module deliver a timing pulse and the number of the PMT channel in which the photon was detected. The photons are accumulated by a multidimensional time‐correlated single photon counting (TCSPC) process. The recording process builds up a four‐dimensional photon distribution over the times of the photons in the excitation pulse period, the wavelengths of the photons, and the coordinates of the scan area. The method delivers a near‐ideal counting efficiency and is capable of resolving double‐exponential decay functions. We demonstrate the performance of the technique for autofluorescence imaging of tissue. Microsc. Res. Tech., 2007.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6089, 608903
Spectrally resolved fluorescence lifetime and FRET measurements
We present two different approaches that allow multi-wavelength fluorescence lifetime measurements in the time domain in conjunction with a laser scanning microscope and a pulsed excitation source. One technique is based on a streak camera system, the other technique is based on a time-correlated-single-photon-counting (TCSPC) approach. The complete setup consists of a laser scanning microscope (LSM-510, Zeiss), a polychromator (250is, Chromex), a streak camera (C5680 with M5677 sweep unit, Hamamatsu Photonics) or a 16-channel TCSPC detector head (PML-16, Becker and Hickl) connected to a TCSPC imaging module (SPC-730/SPC-830, Becker and Hickl). With these techniques it is possible to acquire fluorescence decays in several wavelength regions simultaneously. The fluorescence emitted by the sample can be recorded in a single measurement. No filters have to be used to separate the contributions of different fluorophores to the overall fluorescence signal. When applied to Forster resonance energy transfer (FRET) measurements, the technique allows to separate the decay components of the donor and acceptor fluorescence. In this way, it is possible to reliably determine FRET efficiencies between acceptor and donor fluorophores in given subcellular structures.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6089, 608903
Spectrally resolved fluorescence lifetime and FRET measurements
We present two different approaches that allow multi-wavelength fluorescence lifetime measurements in the time domain in conjunction with a laser scanning microscope and a pulsed excitation source. One technique is based on a streak camera system, the other technique is based on a time-correlated-single-photon-counting (TCSPC) approach. The complete setup consists of a laser scanning microscope (LSM-510, Zeiss), a polychromator (250is, Chromex), a streak camera (C5680 with M5677 sweep unit, Hamamatsu Photonics) or a 16-channel TCSPC detector head (PML-16, Becker and Hickl) connected to a TCSPC imaging module (SPC-730/SPC-830, Becker and Hickl). With these techniques it is possible to acquire fluorescence decays in several wavelength regions simultaneously. The fluorescence emitted by the sample can be recorded in a single measurement. No filters have to be used to separate the contributions of different fluorophores to the overall fluorescence signal. When applied to Forster resonance energy transfer (FRET) measurements, the technique allows to separate the decay components of the donor and acceptor fluorescence. In this way, it is possible to reliably determine FRET efficiencies between acceptor and donor fluorophores in given subcellular structures.
- 30 June 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5862
Time- and wavelength-resolved autofluorescence detection by multi-dimensional TCSPC
We present a multi-dimensional TCSPC technique that simultaneously records the photon distribution over the time in the fluorescence decay, the wavelength, and the coordinates of a two-dimensional scan. We demonstrate the application of the technique to single-point autofluorescence measurements of skin, to multi-spectral fluorescence lifetime microscopy, and ophthalmic imaging.
- 30 June 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5862
Time- and wavelength-resolved autofluorescence detection by multi-dimensional TCSPC
We present a multi-dimensional TCSPC technique that simultaneously records the photon distribution over the time in the fluorescence decay, the wavelength, and the coordinates of a two-dimensional scan. We demonstrate the application of the technique to single-point autofluorescence measurements of skin, to multi-spectral fluorescence lifetime microscopy, and ophthalmic imaging.