The Effect of Different Gadolinium Delivery Rates on Objective and Subjective Image Quality in Cardiac Perfusion Magnetic Resonance Imaging
Open Access
- 8 October 2026
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
Abstract
Background: Stress perfusion cardiac magnetic resonance imaging (MRI) enables accurate detection of myocardial ischemia. While contrast injection parameters, particularly iodine delivery rate, are known to influence image quality in CT, their impact in cardiac MRI remains insufficiently studied. This study aimed to evaluate the effect of different gadolinium-based contrast agent (GBCA) injection rates on objective and subjective image quality in perfusion cardiac MRI in patients with suspected ischemic heart disease. Methods: Ninety patients scheduled for a stress perfusion cardiac MRI were retrospectively included and allocated to 3 groups based on the GBCA injection rate used (eg, group 1: 6 mL/s, group 2: 4 mL/s, and group 3: 2 mL/s). Blood-pool signal intensity was extracted on a frame-by-frame basis to generate signal-intensity time curves. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for all relevant regions, including SNR ischemia , SNR blood , SNR myocardium , CNR ischemia–blood , CNR myocardium–blood , and CNR ischemia–myocardium . Subjective image quality was scored on a 5-point Likert scale, blindly assessed in consensus by 2 cardiovascular radiologists. Results: Blood-pool peak intensity was the highest in the group with flow rates of 6 mL/s. Peak signal intensity was for the 6, 4, and 2 mL/s group, respectively, 17525±3616, 15213±3416, and 15534±2990 a.u. ( P =0.019) and post hoc comparison demonstrated a significant difference between the 6 mL/s and 4 mL/s group ( P =0.027). No significant differences in signal intensity of the myocardium, blood pool and the infarcted region were found between groups ( P =0.475, 0.399 and 0.519, respectively). Image noise was significantly higher in group 1 compared to group 3 ( P value=0.036). SNR of myocardium, blood, and ischemia was not significantly different between groups ( P =0.525, 0.595, and 0.453, respectively). CNR for ischemia-blood, myocardium-blood and ischemia-myocardium were the highest in group 3, but not significantly different ( P =0.373, 0.896, and 0.346, respectively). Subjective image quality and reader confidence were not significantly different between groups ( P values of 0.985 and 0.842). Although contrast quality demonstrated a statistically significant difference across groups ( P =0.026), this finding was not considered clinically relevant. Conclusion: Higher GBCA injection rates resulted in higher blood-pool peak enhancement, yet did not translate into significant differences in objective image and subjective image quality. Lower injection rates appear sufficient to achieve adequate myocardial perfusion imaging, suggesting a plateau in image quality in which increasing flow rates do not show added benefit.Keywords
This publication has 36 references indexed in Scilit:
- Relationship Between Simulated Gadolinium‐Based Contrast Agent Injection Profile and Achievable Resolution Metrics in Contrast‐Enhanced Magnetic Resonance AngiographyJournal of Magnetic Resonance Imaging, 2021
- Quantitative myocardial perfusion in coronary artery disease: A perfusion mapping studyJournal of Magnetic Resonance Imaging, 2019
- Effect of injection rate on contrast‐enhanced MR angiography image quality: Modulation transfer function analysisMagnetic Resonance in Medicine, 2016
- Comparison of stress cardiovascular magnetic resonance imaging (CMR) with stress nuclear perfusion for the diagnosis of coronary artery diseaseJournal of Nuclear Cardiology, 2015
- Basic MR relaxation mechanisms and contrast agent designJournal of Magnetic Resonance Imaging, 2015
- Dynamic contrast-enhanced MRI in mice: An investigation of model parameter uncertaintiesMagnetic Resonance in Medicine, 2014
- System identification theory in pharmacokinetic modeling of dynamic contrast‐enhanced MRI: Influence of contrast injectionMagnetic Resonance in Medicine, 2008
- Accurate assessment of the arterial input function during high‐dose myocardial perfusion cardiovascular magnetic resonanceJournal of Magnetic Resonance Imaging, 2004
- Effect of the rate of gadolinium injection on magnetic resonance pulmonary perfusion imagingJournal of Magnetic Resonance Imaging, 2002
- Arterial first pass gadolinium‐CM dynamics as a function of several intravenous saline flush and Gd volumesJournal of Magnetic Resonance Imaging, 2001