Comparison of 4 mm-sized and 3 mm-sized Stent Retrievers in Mechanical Thrombectomy for M2 Occlusion
- 1 May 2024
- journal article
- research article
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 21 (2) , 157-165
Abstract
Introduction: A stent retriever (SR) is widely used in mechanical thrombectomy (MT) for M2 segment occlusion. However, the suitable size of SR in M2 occlusion remains unclear. Therefore, we aimed to compare 4 mm-sized SR with 3 mm-sized SR in M2 occlusion. Methods: Patients who underwent MT with SR for M2 occlusion were dichotomized into 4×20 mm SR and 3×20 mm SR groups. Then, 1:1 propensity score matching was performed. The M2 segment was divided into proximal and distal segments according to the occlusion site. Subgroup analysis was then performed for each cohort. Results: A total of 111 patients were enrolled, with 4×20 mm SR and 3×20 mm SR applied in 72 (64.9%) and 39 (35.1%) cases, respectively. In propensity score matching, mean number of stent passages for reperfusion was significantly lower in the 4×20 mm SR group than in the 3×20 mm SR group (1.5 ± 0.8 vs. 2.1 ± 1.1; p = 0.004). First-pass reperfusion (FPR) was more highly achieved in the 4×20 mm SR group than in the 3×20 mm SR group (52.6% vs. 42.1%; p = 0.007). In both proximal and distal occlusion cohorts, the 4 mm SR group showed lower mean number of SR passage (p = 0.004 and p = 0.003, respectively) and higher FPR rate than the 3 mm SR group (p = 0.003 and p = 0.007, respectively). Conclusion: In MT for M2 occlusion, 4×20 mm SR enables an effective procedure with lesser SR passage for reperfusion and a higher rate of FPR than 3×20 mm SR.Keywords
This publication has 44 references indexed in Scilit:
- Mechanical Thrombectomy for M2 Segment Occlusion in Acute Ischemic Stroke: A Systematic Review and Meta-AnalysisWorld Neurosurgery, 2022
- Endovascular Thrombectomy Versus Medical Management in Isolated M2 Occlusions: Pooled Patient‐Level Analysis from the EXTEND‐IA Trials, INSPIRE, and SELECT StudiesAnnals of Neurology, 2022
- Multicentric Experience with an Intermediate Aspiration Catheter for Distal M2 Ischemic StrokeJournal of Stroke and Cerebrovascular Diseases, 2020
- M2 segment thrombectomy is not associated with increased complication risk compared to M1 segment: A meta-analysis of recent literatureJournal of Stroke and Cerebrovascular Diseases, 2020
- Hybrid mechanical thrombectomy for acute ischemic stroke using an intermediate aspiration catheter and Trevo stent simultaneouslyJournal of Clinical Neuroscience, 2020
- Single-Center Experience of Mechanical Thrombectomy with the Trevo XP ProVue 6 × 25 mm Stent Retriever in Middle Cerebral Artery Occlusion: Comparison with Trevo XP ProVue 4 × 20 mmWorld Neurosurgery, 2017
- Effect of Endovascular Contact Aspiration vs Stent Retriever on Revascularization in Patients With Acute Ischemic Stroke and Large Vessel OcclusionJAMA, 2017
- Endovascular Therapy for Acute Ischemic Stroke With Occlusion of the Middle Cerebral Artery M2 SegmentJAMA Neurology, 2016
- Tri-axial system using the Solitaire-FR and Penumbra Aspiration Microcatheter for acute mechanical thrombectomyJournal of Clinical Neuroscience, 2013
- Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): a randomised trialThe Lancet, 2012