Ho Jun Yi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ho Jun Yi has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Dong Hoon Lee
Department of Neurosurgery, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
14 shared publications - Jae Hoon Sung
Department of Neurosurgery, St. Vincent’s Hospital, The Catholic University of Korea, Suwon, Korea
14 shared publications Dong Hoon Lee
Department of Neurosurgery, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
13 shared publicationsJae Hoon Sung
Department of Neurosurgery, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
11 shared publicationsDong-Seong Shin
Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Bucheon, Korea
8 shared publicationsBum-Tae Kim
Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Bucheon, Korea
7 shared publications
Latest Publications
- 9 June 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
Predictive Value of Pan-Immune-Inflammation Value for Recurrence of Chronic Subdural Hematoma after Burr Hole Drainage
The Pan-Immune-Inflammation Value (PIV) is a novel composite biomarker that reflects systemic inflammatory status. This study aimed to assess the prognostic value of preoperative PIV in predicting recurrence after burr hole drainage (BHD) in patients with chronic subdural hematoma (CSDH). We conducted a retrospective analysis of 521 patients who underwent BHD for CSDH between January 2015 and October 2025. Preoperative inflammatory markers, including PIV, the systemic Immune-Inflammation Index (SII), and the systemic Inflammation Response Index (SIRI), were calculated. We performed receiver operating characteristic (ROC) curve analysis and multivariate logistic regression to identify predictive factors for recurrence after BHD. Recurrence was observed in 123 patients (23.6%). The recurrence group had a significantly higher mean PIV value compared to the non-recurrence group (481.8 ± 211.2 vs. 259.4 ± 164.7, p = 0.020). ROC analysis showed that PIV had the highest predictive accuracy for recurrence, with an area under the curve of 0.801 (95% confidence interval [CI] 0.753-0.850; p < 0.001). The optimal cutoff value for PIV to predict recurrence after BHD was determined to be 311.4. In multivariate analysis, elevated SII (≥ 551.2) (odds ratio [OR] 1.12, 95% CI 1.06-1.38; p = 0.048) and elevated PIV (≥ 311.4) (OR 1.28, 95% CI 1.08-1.86; p = 0.022) were identified as independent predictors of recurrence after BHD. Preoperative PIV is a strong, independent predictor of CSDH recurrence following BHD. Further research is needed to validate the prognostic role of PIV in patients with CSDH.
- 9 June 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
Predictive Value of Pan-Immune-Inflammation Value for Recurrence of Chronic Subdural Hematoma after Burr Hole Drainage
The Pan-Immune-Inflammation Value (PIV) is a novel composite biomarker that reflects systemic inflammatory status. This study aimed to assess the prognostic value of preoperative PIV in predicting recurrence after burr hole drainage (BHD) in patients with chronic subdural hematoma (CSDH). We conducted a retrospective analysis of 521 patients who underwent BHD for CSDH between January 2015 and October 2025. Preoperative inflammatory markers, including PIV, the systemic Immune-Inflammation Index (SII), and the systemic Inflammation Response Index (SIRI), were calculated. We performed receiver operating characteristic (ROC) curve analysis and multivariate logistic regression to identify predictive factors for recurrence after BHD. Recurrence was observed in 123 patients (23.6%). The recurrence group had a significantly higher mean PIV value compared to the non-recurrence group (481.8 ± 211.2 vs. 259.4 ± 164.7, p = 0.020). ROC analysis showed that PIV had the highest predictive accuracy for recurrence, with an area under the curve of 0.801 (95% confidence interval [CI] 0.753-0.850; p < 0.001). The optimal cutoff value for PIV to predict recurrence after BHD was determined to be 311.4. In multivariate analysis, elevated SII (≥ 551.2) (odds ratio [OR] 1.12, 95% CI 1.06-1.38; p = 0.048) and elevated PIV (≥ 311.4) (OR 1.28, 95% CI 1.08-1.86; p = 0.022) were identified as independent predictors of recurrence after BHD. Preoperative PIV is a strong, independent predictor of CSDH recurrence following BHD. Further research is needed to validate the prognostic role of PIV in patients with CSDH.
- 9 May 2026
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 150, 112069
Initial clinical experience with the paragon balloon guide catheter in mechanical thrombectomy: a multicenter comparative study
- 9 May 2026
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 150, 112069
Initial clinical experience with the paragon balloon guide catheter in mechanical thrombectomy: a multicenter comparative study
- Open Access
- 1 May 2025
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 68 (3) , 369-372
New Perspectives into the Combined Pterional and Interhemispheric Approach during Ruptured Anterior Communicating Artery Aneurysm Surgery in the Endovascular Treatment Era
- 1 May 2025
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 68 (3) , 369-372
Open AccessNew Perspectives into the Combined Pterional and Interhemispheric Approach during Ruptured Anterior Communicating Artery Aneurysm Surgery in the Endovascular Treatment Era
- Open Access
- 1 January 2025
- Published by XMLink in Journal of Korean Medical Science
- Vol. 40 (16) , e44
A Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Lee JY, et al. J Korean Med Sci. 2024 Dec;40(16):e44. https://doi.org/10.3346/jkms.2025.40.e44
- 1 January 2025
- Published by XMLink in Journal of Korean Medical Science
- Vol. 40 (16) , e44
Open AccessA Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Lee JY, et al. J Korean Med Sci. 2024 Dec;40(16):e44. https://doi.org/10.3346/jkms.2025.40.e44
- 1 May 2024
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 21 (2) , 157-165
Comparison of 4 mm-sized and 3 mm-sized Stent Retrievers in Mechanical Thrombectomy for M2 Occlusion
Introduction: A stent retriever (SR) is widely used in mechanical thrombectomy (MT) for M2 segment occlusion. However, the suitable size of SR in M2 occlusion remains unclear. Therefore, we aimed to compare 4 mm-sized SR with 3 mm-sized SR in M2 occlusion. Methods: Patients who underwent MT with SR for M2 occlusion were dichotomized into 4×20 mm SR and 3×20 mm SR groups. Then, 1:1 propensity score matching was performed. The M2 segment was divided into proximal and distal segments according to the occlusion site. Subgroup analysis was then performed for each cohort. Results: A total of 111 patients were enrolled, with 4×20 mm SR and 3×20 mm SR applied in 72 (64.9%) and 39 (35.1%) cases, respectively. In propensity score matching, mean number of stent passages for reperfusion was significantly lower in the 4×20 mm SR group than in the 3×20 mm SR group (1.5 ± 0.8 vs. 2.1 ± 1.1; p = 0.004). First-pass reperfusion (FPR) was more highly achieved in the 4×20 mm SR group than in the 3×20 mm SR group (52.6% vs. 42.1%; p = 0.007). In both proximal and distal occlusion cohorts, the 4 mm SR group showed lower mean number of SR passage (p = 0.004 and p = 0.003, respectively) and higher FPR rate than the 3 mm SR group (p = 0.003 and p = 0.007, respectively). Conclusion: In MT for M2 occlusion, 4×20 mm SR enables an effective procedure with lesser SR passage for reperfusion and a higher rate of FPR than 3×20 mm SR.
- 1 May 2024
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 21 (2) , 157-165
Comparison of 4 mm-sized and 3 mm-sized Stent Retrievers in Mechanical Thrombectomy for M2 Occlusion
Introduction: A stent retriever (SR) is widely used in mechanical thrombectomy (MT) for M2 segment occlusion. However, the suitable size of SR in M2 occlusion remains unclear. Therefore, we aimed to compare 4 mm-sized SR with 3 mm-sized SR in M2 occlusion. Methods: Patients who underwent MT with SR for M2 occlusion were dichotomized into 4×20 mm SR and 3×20 mm SR groups. Then, 1:1 propensity score matching was performed. The M2 segment was divided into proximal and distal segments according to the occlusion site. Subgroup analysis was then performed for each cohort. Results: A total of 111 patients were enrolled, with 4×20 mm SR and 3×20 mm SR applied in 72 (64.9%) and 39 (35.1%) cases, respectively. In propensity score matching, mean number of stent passages for reperfusion was significantly lower in the 4×20 mm SR group than in the 3×20 mm SR group (1.5 ± 0.8 vs. 2.1 ± 1.1; p = 0.004). First-pass reperfusion (FPR) was more highly achieved in the 4×20 mm SR group than in the 3×20 mm SR group (52.6% vs. 42.1%; p = 0.007). In both proximal and distal occlusion cohorts, the 4 mm SR group showed lower mean number of SR passage (p = 0.004 and p = 0.003, respectively) and higher FPR rate than the 3 mm SR group (p = 0.003 and p = 0.007, respectively). Conclusion: In MT for M2 occlusion, 4×20 mm SR enables an effective procedure with lesser SR passage for reperfusion and a higher rate of FPR than 3×20 mm SR.
- 1 May 2024
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 21 (2) , 131-138
Predictors of Emboli in Mechanical Thrombectomy for Anterior Circulation Stroke
Objective: Emboli commonly occurs in mechanical thrombectomy (MT). The objective of this study was to analyze predicting factors of emboli after MT. Methods: Patients who underwent MT with successful reperfusion for anterior circulation occlusion were enrolled. Emboli included distal emboli at digital subtraction angiography (DSA) and unexpected embolic infarct on diffusion-weighted image (DWI) without distal emboli at DSA. Baseline characteristics, procedural details, angiographic outcomes, and clinical outcomes were reviewed. Multivariable analyses were performed to evaluate predictive factors for the occurrence of emboli. Results: Of 601 patients, 149 (24.8%) patients had distal emboli at DSA, and 169 (28.1%) patients had unexpected embolic infarction on DWI even without distal emboli at DSA. A total of 318 (52.9%) patients were enrolled in the embolic group, and 283 (47.1%) patients were assigned to the non-embolic group. In multivariate analysis, larger microcatheter (OR 1.26, 95% CI 1.12–1.94; p = 0.047), clot passage (OR 1.33, 95% CI 1.07–1.87; p = 0.041), use of balloon guide catheter (BGC) (OR 0.70, 95% CI 0.52–0.92; p = 0.014), early ballooning of BGC (OR 0.68, 95% CI 0.50–0.90; p = 0.009), and longer stent retriever (OR 0.72, 95% CI 0.54–0.90; p = 0.029) were associated with occurrence of emboli. Conclusion: MT with only a stent retriever, use of a larger microcatheter, and clot passage might increase the risk of emboli. In contrast, contact aspiration thrombectomy, use of BGC, early ballooning of BGC, and use of longer stent retrievers could reduce the chance of emboli.
- 1 May 2024
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 21 (2) , 131-138
Predictors of Emboli in Mechanical Thrombectomy for Anterior Circulation Stroke
Objective: Emboli commonly occurs in mechanical thrombectomy (MT). The objective of this study was to analyze predicting factors of emboli after MT. Methods: Patients who underwent MT with successful reperfusion for anterior circulation occlusion were enrolled. Emboli included distal emboli at digital subtraction angiography (DSA) and unexpected embolic infarct on diffusion-weighted image (DWI) without distal emboli at DSA. Baseline characteristics, procedural details, angiographic outcomes, and clinical outcomes were reviewed. Multivariable analyses were performed to evaluate predictive factors for the occurrence of emboli. Results: Of 601 patients, 149 (24.8%) patients had distal emboli at DSA, and 169 (28.1%) patients had unexpected embolic infarction on DWI even without distal emboli at DSA. A total of 318 (52.9%) patients were enrolled in the embolic group, and 283 (47.1%) patients were assigned to the non-embolic group. In multivariate analysis, larger microcatheter (OR 1.26, 95% CI 1.12–1.94; p = 0.047), clot passage (OR 1.33, 95% CI 1.07–1.87; p = 0.041), use of balloon guide catheter (BGC) (OR 0.70, 95% CI 0.52–0.92; p = 0.014), early ballooning of BGC (OR 0.68, 95% CI 0.50–0.90; p = 0.009), and longer stent retriever (OR 0.72, 95% CI 0.54–0.90; p = 0.029) were associated with occurrence of emboli. Conclusion: MT with only a stent retriever, use of a larger microcatheter, and clot passage might increase the risk of emboli. In contrast, contact aspiration thrombectomy, use of BGC, early ballooning of BGC, and use of longer stent retrievers could reduce the chance of emboli.
- 13 February 2024
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 121, 47-52
Pan-immune-inflammation value predict delayed cerebral ischemia in patients with aneurysmal subarachnoid hemorrhage
- 13 February 2024
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 121, 47-52
Pan-immune-inflammation value predict delayed cerebral ischemia in patients with aneurysmal subarachnoid hemorrhage
- 1 February 2023
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 20 (1) , 124-131
Effect of Early Balloon Inflation of Balloon Guide Catheter in Mechanical Thrombectomy for Large Vessel Occlusion
Objective: A balloon guide catheter (BGC) is widely used in mechanical thrombectomy (MT). However, the balloon inflation timing of BGC has not been clearly established. We evaluated whether balloon inflation timing of BGC affects the results of MT. Methods: Patients who underwent MT with BGC for anterior circulation occlusion were enrolled. Patients were dichotomized into early and late balloon inflation groups, according to the timing of BGC inflation. Angiographic and clinical outcomes were compared between the two groups. Multivariable analyses were performed to evaluate the predictive factors for first-pass reperfusion (FPR) and successful reperfusion (SR). Results: Of 436 patients, the early balloon inflation group showed a shorter procedure time (21 min (11-37) vs. 29 min (14-46), p = 0.014), a higher rate of SR with aspiration only (64.0% vs. 55.4%, p = 0.016), a lower aspiration catheter delivery failure rate (11.1% vs. 19.4%, p = 0.005), less frequent technique conversion (36.0% vs. 44.5%, p = 0.009), higher rate of FPR (58.2% vs. 50.2%, p = 0.011), and a lower rate of distal embolization (7.9% vs. 11.7%, P = 0.006), compared to the late balloon inflation group. In multivariate analysis, early balloon inflation was an independent predictor for FPR (odds ratio, OR 1.53, 95% confidence interval, CI 1.37–2.57; p = 0.011) and SR (OR 1.26, 95% CI 1.18-1.64; p = 0.018). Conclusion: Early balloon inflation of BGC enables an effective procedure than late balloon inflation. Early balloon inflation was associated with higher rates of FPR and SR.
- 1 February 2023
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 20 (1) , 124-131
Effect of Early Balloon Inflation of Balloon Guide Catheter in Mechanical Thrombectomy for Large Vessel Occlusion
Objective: A balloon guide catheter (BGC) is widely used in mechanical thrombectomy (MT). However, the balloon inflation timing of BGC has not been clearly established. We evaluated whether balloon inflation timing of BGC affects the results of MT. Methods: Patients who underwent MT with BGC for anterior circulation occlusion were enrolled. Patients were dichotomized into early and late balloon inflation groups, according to the timing of BGC inflation. Angiographic and clinical outcomes were compared between the two groups. Multivariable analyses were performed to evaluate the predictive factors for first-pass reperfusion (FPR) and successful reperfusion (SR). Results: Of 436 patients, the early balloon inflation group showed a shorter procedure time (21 min (11-37) vs. 29 min (14-46), p = 0.014), a higher rate of SR with aspiration only (64.0% vs. 55.4%, p = 0.016), a lower aspiration catheter delivery failure rate (11.1% vs. 19.4%, p = 0.005), less frequent technique conversion (36.0% vs. 44.5%, p = 0.009), higher rate of FPR (58.2% vs. 50.2%, p = 0.011), and a lower rate of distal embolization (7.9% vs. 11.7%, P = 0.006), compared to the late balloon inflation group. In multivariate analysis, early balloon inflation was an independent predictor for FPR (odds ratio, OR 1.53, 95% confidence interval, CI 1.37–2.57; p = 0.011) and SR (OR 1.26, 95% CI 1.18-1.64; p = 0.018). Conclusion: Early balloon inflation of BGC enables an effective procedure than late balloon inflation. Early balloon inflation was associated with higher rates of FPR and SR.