Quantitative perfusion and water transport time model from multi b-value diffusion magnetic resonance imaging validated against neutron capture microspheres
Preprint
Abstract
Intravoxel Incoherent Motion (IVIM) is a non-contrast magnetic resonance imaging diffusion-based scan that uses a multitude of b-values to measure various speeds of molecular perfusion and diffusion, sidestepping inaccuracy of arterial input functions or bolus kinetics in quantitative imaging. We test a new method of IVIM quantification and compare our values to reference standard neutron capture microspheres across normocapnia, CO2 induced hypercapnia, and middle cerebral artery occlusion in a controlled animal model. Perfusion quantification in ml/100g/min compared to microsphere perfusion uses the 3D gaussian probability distribution and defined water transport time as when 50% of the molecules remain in the tissue of interest. Perfusion, water transport time, and infarct volume was compared to reference standards. Simulations were studied to suppress non-specific cerebrospinal fluid (CSF). Linear regression analysis of quantitative perfusion returned correlation (slope = .55, intercept = 52.5, $R^2$= .64). Linear regression for water transport time asymmetry in infarcted tissue was excellent (slope = .59, intercept = .3, $R^2$ = .93). Strong linear agreement also was found for infarct volume (slope = 1.01, $R^2$= .79). Simulation of CSF suppression via inversion recovery returned blood signal reduced by 82% from combined T1 and T2 effects. Intra-physiologic state comparison of perfusion shows potential partial volume effects which require further study especially in disease states. The accuracy and sensitivity of IVIM provides evidence that observed signal changes reflect cytotoxic edema and tissue perfusion. Partial volume contamination of CSF may be better removed during post-processing rather than with inversion recovery to avoid artificial loss of blood signal.
Keywords
All Related Versions
This publication has 22 references indexed in Scilit:
- Absolute quantitative MR perfusion and comparison against stable‐isotope microspheresMagnetic Resonance in Medicine, 2019
- Comparison of methods for estimation of the intravoxel incoherent motion (IVIM) diffusion coefficient (D) and perfusion fraction (f)Magnetic Resonance Materials in Physics, Biology and Medicine, 2018
- Quantitative assessment of hyperacute cerebral infarction with intravoxel incoherent motion MR imaging: Initial experience in a canine stroke modelJournal of Magnetic Resonance Imaging, 2016
- Intravoxel incoherent motion diffusion-weighted imaging in stroke patients: initial clinical experienceClinical Radiology, 2016
- IVIM perfusion fraction is prognostic for survival in brain gliomaClinical Neuroradiology, 2016
- Stroke assessment with intravoxel incoherent motion diffusion‐weighted MRINMR in Biomedicine, 2016
- Caveat of measuring perfusion indexes using intravoxel incoherent motion magnetic resonance imaging in the human brainEuropean Radiology, 2015
- Correction for arterial‐tissue delay and dispersion in absolute quantitative cerebral perfusion DSC MR imagingMagnetic Resonance in Medicine, 2011
- Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous systemEuropean Journal of Radiology, 1999
- CSF‐suppressed quantitative single‐shot diffusion imagingMagnetic Resonance in Medicine, 1991