THE THERMOLUMINESCENCE (TL) DOSE RESPONSE OF COMPOSITE PEAK 5 IN LIF:MG,TI (TLD-100): DEPENDENCE ON THE ORDER OF KINETICS
- 28 February 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (6) , 498-508
Abstract
A seeming contradiction in the prediction of the spatially correlated trapping center/luminescent center model applied to LiF:Mg,Ti has been the linear/supralinear behavior of the dose response of glow peak 5a. In the TC/LC model, the localised electron–hole recombination, giving rise to glow peak 5a, is expected to result in an extended region of linear dose response. Deconvolution of the glow curves based on first order kinetic peak shapes results, however, in a dose response of peak 5a, which closely resembles the linear/supralinear dose response of peak 5. It is demonstrated herein that when general-order kinetics peak shapes are used for peak 5a, the analysis can result in a linear dose response of glow peak 5a up to dose levels as high as 30 Gy, well beyond the 1-Gy onset of supralinearity of peak 5. The extended linearity suggests a resolution of the contradiction.Keywords
Funding Information
- PAZY Foundation
- Israeli Ministry of Science and Technology (3-16316, 580298347)
This publication has 24 references indexed in Scilit:
- Thermoluminescence emission from localized recombination modelJournal of Physics D: Applied Physics, 2006
- Thermally stimulated luminescence arising simultaneously from localized and delocalized recombination processesJournal of Physics D: Applied Physics, 2006
- Tunnelling in Afterglow: its Coexistence and Interweaving with Thermally Stimulated LuminescenceRadiation Protection Dosimetry, 2002
- Extended Defect Models for ThermoluminescenceRadiation Protection Dosimetry, 1999
- Mixed-order kinetic analysis of the glow curve characteristics of single crystal LiF:Mg,Ti as a function of Ti concentrationRadiation Measurements, 1998
- Study of the Kinetics of Peak 5 in LiF:Mg,Ti: Dose Dependence of the Thermoluminescence Isothermal Decay at 165°CMaterials Science Forum, 1997
- Interpretation of Very High Activation Energies and Frequency Factors in TL as Being Due to Competition Between CentresRadiation Protection Dosimetry, 1996
- Computerized glow curve deconvolution applied to the analysis of the kinetics of peak 5 in LiF:Mg,Ti (TLD-100)Journal of Physics D: Applied Physics, 1995
- The kinetics of TL peaks and its effect on the dose versus temperature plotRadiation Measurements, 1994
- Measurements of the emission spectra of LiF during thermoluminescenceRadiation Effects, 1983