Dimitry Nemirovsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Dimitry Nemirovsky has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Yacov Finkelstein
Chemistry Division, Nuclear Research Center Negev (NRCN), Beer-Sheva 84190, Israel
7 shared publications R. Moreh
Physics Department, Ben-Gurion University of the Negev, Beer-Sheva, 84105, Israel
6 shared publications- R. Moreh
Department of Physics, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
5 shared publications - Victor Kagalovsky
Shamoon College of Engineering, Beer-Sheva 8410802 , Israel
5 shared publications Izhak Ladizhensky
Department of Mechanical Engineering Sami Shamoon College of Engineering Beer‐Sheva Israel
4 shared publicationsJ Mayers
Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX, UK
4 shared publications
Latest Publications
- 12 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 581
Kinetic simulation of the glow curve and isothermal decay in the thermoluminescence of LiF:Mg,Ti: the spatially correlated trapping center/luminescent center model
- 12 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 581
Kinetic simulation of the glow curve and isothermal decay in the thermoluminescence of LiF:Mg,Ti: the spatially correlated trapping center/luminescent center model
- Open Access
Unsupervised Techniques to Detect Quantum Chaos
Conventional spectral probes of quantum chaos require eigenvalues, and sometimes, eigenvectors of the quantum Hamiltonian. This involves computationally expensive diagonalization procedures. We test whether an unsupervised neural network can detect quantum chaos directly from the Hamiltonian matrix. We use a single-body Hamiltonian with an underlying random graph structure and random coupling constants, with a parameter that determines the randomness of the graph. The spectral analysis shows that increasing the amount of randomness in the underlying graph results in a transition from integrable spectral statistics to chaotic ones. We show that the same transition can be detected via unsupervised neural networks, or more specifically, Self-Organizing Maps by feeding the Hamiltonian matrix directly into the neural network, without any diagonalization procedure.
Open AccessUnsupervised Techniques to Detect Quantum Chaos
Conventional spectral probes of quantum chaos require eigenvalues, and sometimes, eigenvectors of the quantum Hamiltonian. This involves computationally expensive diagonalization procedures. We test whether an unsupervised neural network can detect quantum chaos directly from the Hamiltonian matrix. We use a single-body Hamiltonian with an underlying random graph structure and random coupling constants, with a parameter that determines the randomness of the graph. The spectral analysis shows that increasing the amount of randomness in the underlying graph results in a transition from integrable spectral statistics to chaotic ones. We show that the same transition can be detected via unsupervised neural networks, or more specifically, Self-Organizing Maps by feeding the Hamiltonian matrix directly into the neural network, without any diagonalization procedure.
- 1 December 2024
- Published by AIP Publishing in Low Temperature Physics
- Vol. 50 (12) , 1127-1134
Unsupervised techniques to detect quantum chaos
Conventional spectral probes of quantum chaos require eigenvalues, and sometimes, eigenvectors of the quantum Hamiltonian. This involves computationally expensive diagonalization procedures. We test whether an unsupervised neural network can detect quantum chaos directly from the Hamiltonian matrix. We use a single-body Hamiltonian with an underlying random graph structure and random coupling constants, with a parameter that determines the randomness of the graph. The spectral analysis shows that increasing the amount of randomness in the underlying graph results in a transition from integrable spectral statistics to chaotic ones. We show that the same transition can be detected via unsupervised neural networks, or more specifically, self-organizing maps by feeding the Hamiltonian matrix directly into the neural network, without any diagonalization procedure.
- 1 December 2024
- Published by AIP Publishing in Low Temperature Physics
- Vol. 50 (12) , 1127-1134
Unsupervised techniques to detect quantum chaos
Conventional spectral probes of quantum chaos require eigenvalues, and sometimes, eigenvectors of the quantum Hamiltonian. This involves computationally expensive diagonalization procedures. We test whether an unsupervised neural network can detect quantum chaos directly from the Hamiltonian matrix. We use a single-body Hamiltonian with an underlying random graph structure and random coupling constants, with a parameter that determines the randomness of the graph. The spectral analysis shows that increasing the amount of randomness in the underlying graph results in a transition from integrable spectral statistics to chaotic ones. We show that the same transition can be detected via unsupervised neural networks, or more specifically, self-organizing maps by feeding the Hamiltonian matrix directly into the neural network, without any diagonalization procedure.
- 9 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (4) , 423-427
The effect of cooling rate on the precision of measurement of glow peak 5 in the thermoluminescence of LiF:Mg,Ti (TLD-100)
The effect of natural rapid cooling and oven slow cooling on the precision of thermoluminescence measurements of LiF:Mg,Ti is investigated. Three separate series of measurements resulted in average precisions of 5.1 and 5.0%, respectively. However, the highest precision of 1.7% (1 SD) was achieved for an oven-cooled material.
- 9 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (4) , 423-427
The effect of cooling rate on the precision of measurement of glow peak 5 in the thermoluminescence of LiF:Mg,Ti (TLD-100)
The effect of natural rapid cooling and oven slow cooling on the precision of thermoluminescence measurements of LiF:Mg,Ti is investigated. Three separate series of measurements resulted in average precisions of 5.1 and 5.0%, respectively. However, the highest precision of 1.7% (1 SD) was achieved for an oven-cooled material.
- 28 February 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (6) , 498-508
THE THERMOLUMINESCENCE (TL) DOSE RESPONSE OF COMPOSITE PEAK 5 IN LIF:MG,TI (TLD-100): DEPENDENCE ON THE ORDER OF KINETICS
A seeming contradiction in the prediction of the spatially correlated trapping center/luminescent center model applied to LiF:Mg,Ti has been the linear/supralinear behavior of the dose response of glow peak 5a. In the TC/LC model, the localised electron–hole recombination, giving rise to glow peak 5a, is expected to result in an extended region of linear dose response. Deconvolution of the glow curves based on first order kinetic peak shapes results, however, in a dose response of peak 5a, which closely resembles the linear/supralinear dose response of peak 5. It is demonstrated herein that when general-order kinetics peak shapes are used for peak 5a, the analysis can result in a linear dose response of glow peak 5a up to dose levels as high as 30 Gy, well beyond the 1-Gy onset of supralinearity of peak 5. The extended linearity suggests a resolution of the contradiction.
- 28 February 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (6) , 498-508
THE THERMOLUMINESCENCE (TL) DOSE RESPONSE OF COMPOSITE PEAK 5 IN LIF:MG,TI (TLD-100): DEPENDENCE ON THE ORDER OF KINETICS
A seeming contradiction in the prediction of the spatially correlated trapping center/luminescent center model applied to LiF:Mg,Ti has been the linear/supralinear behavior of the dose response of glow peak 5a. In the TC/LC model, the localised electron–hole recombination, giving rise to glow peak 5a, is expected to result in an extended region of linear dose response. Deconvolution of the glow curves based on first order kinetic peak shapes results, however, in a dose response of peak 5a, which closely resembles the linear/supralinear dose response of peak 5. It is demonstrated herein that when general-order kinetics peak shapes are used for peak 5a, the analysis can result in a linear dose response of glow peak 5a up to dose levels as high as 30 Gy, well beyond the 1-Gy onset of supralinearity of peak 5. The extended linearity suggests a resolution of the contradiction.
- 1 June 2022
- Published by AIP Publishing in Low Temperature Physics
- Vol. 48 (6) , 452-458
Noise signal as input data in self-organized neural networks
Self-organizing neural networks are used to analyze uncorrelated white noises of different distribution types (normal, triangular, and uniform). The artificially generated noises are analyzed by clustering the measured time signal sequence samples without its preprocessing. Using this approach, we analyze, for the first time, the current noise produced by a sliding “Wigner-crystal”-like structure in the insulating phase of a 2D electron system in silicon. The possibilities of using the method for analyzing and comparing experimental data obtained by observing various effects in solid-state physics and numerical data simulated using theoretical models are discussed.
- 1 June 2022
- Published by AIP Publishing in Low Temperature Physics
- Vol. 48 (6) , 452-458
Noise signal as input data in self-organized neural networks
Self-organizing neural networks are used to analyze uncorrelated white noises of different distribution types (normal, triangular, and uniform). The artificially generated noises are analyzed by clustering the measured time signal sequence samples without its preprocessing. Using this approach, we analyze, for the first time, the current noise produced by a sliding “Wigner-crystal”-like structure in the insulating phase of a 2D electron system in silicon. The possibilities of using the method for analyzing and comparing experimental data obtained by observing various effects in solid-state physics and numerical data simulated using theoretical models are discussed.
- 1 March 2022
- Published by Elsevier in Physica E: Low-dimensional Systems and Nanostructures
- Vol. 137, 115049
Electrostatic potential and magnetic moment of radially insulating Corbino disk
- 1 March 2022
- Published by Elsevier in Physica E: Low-dimensional Systems and Nanostructures
- Vol. 137, 115049
Electrostatic potential and magnetic moment of radially insulating Corbino disk
- 31 August 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (1-2) , 53-59
INVESTIGATION OF THE TL CHARACTERISTICS OF COMPOSITE PEAK 5 IN THE GLOW CURVE OF LIF:MG,TI (TLD-100) USING NATURALLY AND FURNACE-COOLED SAMPLES FOLLOWING THE 400°C PRE-IRRADIATION ANNEAL
The cooling rate to room temperature following the 400°C pre-irradiation anneal is known to affect the thermoluminescent properties of LiF:Mg,Ti (TLD-100) as a result of migration and clustering of defects during the cooling down process. In this investigation the dose response over an extended dose range from 0.01 to 7000 Gy in both naturally cooled and the much slower furnace-cooled samples has been measured. Glow curve deconvolution based on first-order kinetics is employed to extract the dose response of the various glow peaks. Of especial interest is the behaviour of glow peaks 4, 5a and 5 as a function of dose. The idea is to modify the supralinear dose response of peak 5 from 1 to 30 Gy to a linear behaviour. This dose range is important for clinical therapy and a linear dose response is of substantial advantage leading to both improved accuracy and precision.
- 31 August 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (1-2) , 53-59
INVESTIGATION OF THE TL CHARACTERISTICS OF COMPOSITE PEAK 5 IN THE GLOW CURVE OF LIF:MG,TI (TLD-100) USING NATURALLY AND FURNACE-COOLED SAMPLES FOLLOWING THE 400°C PRE-IRRADIATION ANNEAL
The cooling rate to room temperature following the 400°C pre-irradiation anneal is known to affect the thermoluminescent properties of LiF:Mg,Ti (TLD-100) as a result of migration and clustering of defects during the cooling down process. In this investigation the dose response over an extended dose range from 0.01 to 7000 Gy in both naturally cooled and the much slower furnace-cooled samples has been measured. Glow curve deconvolution based on first-order kinetics is employed to extract the dose response of the various glow peaks. Of especial interest is the behaviour of glow peaks 4, 5a and 5 as a function of dose. The idea is to modify the supralinear dose response of peak 5 from 1 to 30 Gy to a linear behaviour. This dose range is important for clinical therapy and a linear dose response is of substantial advantage leading to both improved accuracy and precision.
- 24 July 2021
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 116, 103287
Proton dynamics in a single H2O confined in a Buckyball
- 24 July 2021
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 116, 103287
Proton dynamics in a single H2O confined in a Buckyball