Adaptive Motion Artifact Reduction Based on Empirical Wavelet Transform and Wavelet Thresholding for the Non-Contact ECG Monitoring Systems
Open Access
Abstract
Electrocardiogram (ECG) signals are crucial for determining the health status of the human heart. A clean ECG signal is critical in analysis and diagnosis of heart diseases. However, ECG signals are often contaminated by motion artifact noise in the non-contact ECG monitoring systems. In this paper, an ECG motion artifact removal approach based on empirical wavelet transform (EWT) and wavelet thresholding (WT) is proposed. This method consists of five steps, namely, spectrum preprocessing, spectrum segmentation, EWT decomposition, wavelet threshold denoising, and EWT reconstruction. The proposed approach was used to process real ECG signals collected by the non-contact ECG monitoring equipment. The results of quantitative study and analysis indicate that this approach produces a better performance in terms of restorage of QRS complexes of the original ECG with reduced distortion, retaining useful information in ECG signals, and improvement of the signal to noise ratio (SNR) value of the signal. The output results of the practical ECG signal test show that motion artifact in the real recorded ECG is effectively filtered out. The proposed method is feasible for reducing motion artifacts from ECG signals, whether from simulation ECG signals or practical non-contact ECG monitoring systems.Keywords
Funding Information
- National Natural Science Foundation of China (51673214;61804185)
This publication has 38 references indexed in Scilit:
- Use of power-line interference for adaptive motion artifact removal in biopotential measurementsPhysiological Measurement, 2015
- Discrete-wavelet-transform-based noise removal and feature extraction for ECG signalsIRBM, 2014
- Noncontact ECG Recording System With Real Time Capacitance Measurement for Motion Artifact ReductionIEEE Transactions on Biomedical Circuits and Systems, 2014
- Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory ElectrocardiogramsSensors, 2014
- Transmission characteristics of planar optical waveguide devices on coupling interfaceOptik, 2013
- Crank–Nicolson/quasi-wavelets method for solving fourth order partial integro-differential equation with a weakly singular kernelJournal of Computational Physics, 2013
- ECG signal denoising and baseline wander correction based on the empirical mode decompositionComputers in Biology and Medicine, 2008
- The impact of the MIT-BIH Arrhythmia DatabaseIEEE Engineering in Medicine and Biology Magazine, 2001
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisProceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 1998
- Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detectionIEEE Transactions on Biomedical Engineering, 1991