Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
Authors:
- Marcelo de OliveiraMOMarcelo de Oliveira
- Elaine S. de Pádua MeloEMElaine S. de Pádua Melo
- Thaís Carvalho da SilvaTSThaís Carvalho da Silva
- Carla Maiara Lopes CardozoCCCarla Maiara Lopes Cardozo
- Igor Valadares SiqueiraISIgor Valadares Siqueira
- Mariana Pereira HamajiMHMariana Pereira Hamaji
- Vanessa Torres BragaVBVanessa Torres Braga
- Luiz Fernando Taranta MartinLMLuiz Fernando Taranta Martin
- Alessandro FonsecaAFAlessandro Fonseca
- Valter Aragão Do NascimentoVNValter Aragão Do Nascimento
Open Access
- 7 September 2023
- Vol. 28 (18) , 6508
Abstract
The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical emission spectrometry (ICP OES). The limit of detection (LOD) and limit of quantification (LOQ) values for the quantified elements ranged from 0.0002–0.0363 (mg/L) and 0.0007–0.1211 (mg/L), respectively. High values of concentrations of Al (2.382 µg/g), As (0.204 µg/g), Ba (0.056 µg/g), Cd (0.051 µg/g), Co (1.085 µg/g), Cr (0.020 µg/g), Cu (0.023 µg/g), Fe (0.453 µg/g), Mg (24.284 µg/g), Mn (0.014 µg/g), Mo (0.046 µg/g), Ni (0.071 µg/g), Pb (0.049 µg/g), Se (0.365 µg/g), V (0.083 µg/g), and Zn (0.552 µg/g) were quantified in samples of eye drops with and without preservatives. The concentrations of As (5 samples) and Cd (3 samples) were higher than those allowed by the Brazilian Pharmacopoeia for impurities (parenteral use). The value of Co content (µg/g) in a sample was higher than the value established by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH Q3D (R2)) in the parenteral route. The daily eye drop instillation exposure (µg/day) was below the values from the parenteral-permitted daily exposure (PDE) set by the ICH Q3D guideline (R2). The presence of heavy metals in eye drops is an alert to regulatory agencies in several countries so that control and inspections can be carried out.Keywords
Funding Information
- Brazilian Research Council (CNPq) (310621/2020-8, 001)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (310621/2020-8, 001)
This publication has 72 references indexed in Scilit:
- Evaluation of Essential and Toxic Trace Elements in Pseudoexfoliation Syndrome and Pseudoexfoliation GlaucomaBiological Trace Element Research, 2013
- Levels of Aqueous Humor Trace Elements in Patients with Non-Exsudative Age-related Macular Degeneration: A Case-control StudyPLOS ONE, 2013
- Arsenic: toxicity, oxidative stress and human diseaseJournal of Applied Toxicology, 2011
- Olho seco: etiopatogenia e tratamentoArquivos Brasileiros de Oftalmologia, 2010
- Relationship between glaucoma and selenium levels in plasma and aqueous humourBritish Journal of Ophthalmology, 2008
- Barium NitrateJournal of Chemical Education, 2006
- Aluminum as a toxicantToxicology and Industrial Health, 2002
- VanadiumJournal of Toxicology: Clinical Toxicology, 1999
- Selenium concentrations in serum, lens and aqueous humour of patients with senile cataractActa Ophthalmologica Scandinavica, 1995
- TLC Separation of Transition Metal Ions and Their Quantitative Estimation by Atomic Absorption SpectroscopyJournal of Liquid Chromatography, 1995