Vanessa Torres Braga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vanessa Torres Braga has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Elaine Silva de Pádua Melo
Group of Spectroscopy and Bioinformatics Applied to Biodiversity and Health, Postgraduation Program in Health and Development in the Midwest Region, Faculty of Medicine, Federal University of Mato Grosso do Sul, Campo Grande 79079-900, Mato Grosso do Sul, Brazil
2 shared publications - Marcelo de Oliveira
Faculty of Medicine, Federal University of Mato Grosso do Sul, Campo Grande 79079-900, State of Mato Grosso do Sul, Brazil
2 shared publications - Valter Aragão Do Nascimento
Graduate Program in Health and Development in the Central-West Region of Brazil, Federal University of Mato Grosso do Sul, Campo Grande 79079-900, Brazil
2 shared publications - Alessandro Carvalho da Fonseca
Federal University of Mato Grosso do Sul
1 shared publication - Carla Maiara Lopes Cardozo
Group of Spectroscopy and Bioinformatics Applied Biodiversity and Health (GEBABS), Faculty of Medicine, Federal University of Mato Grosso do Sul, Campo Grande, Brazil
1 shared publication - Diego Azevedo Zoccal Garcia
Group of Spectroscopy and Bioinformatics Applied Biodiversity and Health (GEBABS), Graduate Program in Health and Development in the Central-West Region of Brazil, Federal University of Mato Grosso do Sul, Campo Grande 79079-900, Brazil
1 shared publication
Latest Publications
- Open Access
- 4 January 2026
- Published by MDPI AG in Journal of Pharmaceutical and BioTech Industry
- Vol. 3 (1) , 1
Assessment of Human Health Risks from Exposure to Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
Dry eye disease is a common condition in which tear production or quality is insufficient to lubricate the eyes properly. Standard treatment usually involves lubricating eye drops. In this study, we assessed the human health risks, including both non-carcinogenic and carcinogenic effects, associated with long-term exposure to the chemical elements arsenic (As), cadmium (Cd), cobalt (Co), iron (Fe), nickel (Ni), lead (Pb), and zinc (Zn) in eye drops used in Brazil. The results indicated that the Co concentration (1.1048 mg/kg) in the eye drops sample 5 exceeded the limit established by the ICH Q3D (R2) guideline for parenteral products (0.5000 mg/kg). Additionally, As levels in eye drop samples 2, 8–10, 12, 13, and 16, as well as Cd levels in samples 2, 3, 8–10, and 12, exceeded the limits established by the Brazilian Pharmacopoeia for parenteral administration (0.0500–0.0532 mg/kg). The main health risk appears to come from oral exposure, as the drug can drain into the nasal cavity via the nasolacrimal duct and then be absorbed through the gastrointestinal tract. While none of the tested eye drops posed non-carcinogenic risks, carcinogenic risks from oral exposure to As and Cd were identified, with overall risk levels exceeding acceptable thresholds. These findings emphasize the need for strict regulation and continuous monitoring of these products to reduce health risks and prevent long-term damage.
- 4 January 2026
- Published by MDPI AG in Journal of Pharmaceutical and BioTech Industry
- Vol. 3 (1) , 1
Open AccessAssessment of Human Health Risks from Exposure to Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
Dry eye disease is a common condition in which tear production or quality is insufficient to lubricate the eyes properly. Standard treatment usually involves lubricating eye drops. In this study, we assessed the human health risks, including both non-carcinogenic and carcinogenic effects, associated with long-term exposure to the chemical elements arsenic (As), cadmium (Cd), cobalt (Co), iron (Fe), nickel (Ni), lead (Pb), and zinc (Zn) in eye drops used in Brazil. The results indicated that the Co concentration (1.1048 mg/kg) in the eye drops sample 5 exceeded the limit established by the ICH Q3D (R2) guideline for parenteral products (0.5000 mg/kg). Additionally, As levels in eye drop samples 2, 8–10, 12, 13, and 16, as well as Cd levels in samples 2, 3, 8–10, and 12, exceeded the limits established by the Brazilian Pharmacopoeia for parenteral administration (0.0500–0.0532 mg/kg). The main health risk appears to come from oral exposure, as the drug can drain into the nasal cavity via the nasolacrimal duct and then be absorbed through the gastrointestinal tract. While none of the tested eye drops posed non-carcinogenic risks, carcinogenic risks from oral exposure to As and Cd were identified, with overall risk levels exceeding acceptable thresholds. These findings emphasize the need for strict regulation and continuous monitoring of these products to reduce health risks and prevent long-term damage.
- Open Access
Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical emission spectrometry (ICP OES). The limit of detection (LOD) and limit of quantification (LOQ) values for the quantified elements ranged from 0.0002–0.0363 (mg/L) and 0.0007–0.1211 (mg/L), respectively. High values of concentrations of Al (2.382 µg/g), As (0.204 µg/g), Ba (0.056 µg/g), Cd (0.051 µg/g), Co (1.085 µg/g), Cr (0.020 µg/g), Cu (0.023 µg/g), Fe (0.453 µg/g), Mg (24.284 µg/g), Mn (0.014 µg/g), Mo (0.046 µg/g), Ni (0.071 µg/g), Pb (0.049 µg/g), Se (0.365 µg/g), V (0.083 µg/g), and Zn (0.552 µg/g) were quantified in samples of eye drops with and without preservatives. The concentrations of As (5 samples) and Cd (3 samples) were higher than those allowed by the Brazilian Pharmacopoeia for impurities (parenteral use). The value of Co content (µg/g) in a sample was higher than the value established by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH Q3D (R2)) in the parenteral route. The daily eye drop instillation exposure (µg/day) was below the values from the parenteral-permitted daily exposure (PDE) set by the ICH Q3D guideline (R2). The presence of heavy metals in eye drops is an alert to regulatory agencies in several countries so that control and inspections can be carried out.
Open AccessQuantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical emission spectrometry (ICP OES). The limit of detection (LOD) and limit of quantification (LOQ) values for the quantified elements ranged from 0.0002–0.0363 (mg/L) and 0.0007–0.1211 (mg/L), respectively. High values of concentrations of Al (2.382 µg/g), As (0.204 µg/g), Ba (0.056 µg/g), Cd (0.051 µg/g), Co (1.085 µg/g), Cr (0.020 µg/g), Cu (0.023 µg/g), Fe (0.453 µg/g), Mg (24.284 µg/g), Mn (0.014 µg/g), Mo (0.046 µg/g), Ni (0.071 µg/g), Pb (0.049 µg/g), Se (0.365 µg/g), V (0.083 µg/g), and Zn (0.552 µg/g) were quantified in samples of eye drops with and without preservatives. The concentrations of As (5 samples) and Cd (3 samples) were higher than those allowed by the Brazilian Pharmacopoeia for impurities (parenteral use). The value of Co content (µg/g) in a sample was higher than the value established by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH Q3D (R2)) in the parenteral route. The daily eye drop instillation exposure (µg/day) was below the values from the parenteral-permitted daily exposure (PDE) set by the ICH Q3D guideline (R2). The presence of heavy metals in eye drops is an alert to regulatory agencies in several countries so that control and inspections can be carried out.