A Large‐Scale Test of a Reinforced Concrete Core Wall Subjected to Three‐Dimensional Loading
Authors:
- 12 January 2026
- journal article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (4) , 968-989
Abstract
This paper presents a large‐scale quasi‐static test of a reinforced concrete (RC) core wall under high axial compression force and bidirectional lateral cyclic loads. A virtual 33‐story RC frame‐core wall prototype building was designed per the current Chinese codes, and RC core walls at the lower stories were selected as the substructure for experimental testing. Using a 108 MN spatial loading facility, three‐dimensional loading (including axial compressive force, bidirectional shear forces, and bidirectional overturning moments) was applied to the test structure to investigate the spatial resisting mechanism and seismic behavior of the core wall structure. During the test, the core wall specimen sustained brittle failure at 0.9% drift (corresponding to a top lateral drift of 1.34% for the 33‐story prototype structure) due to the large compressive strain demand (−0.008) in the unconfined region of flange walls. Out‐of‐plane diagonal compression cracks penetrated the entire sectional length of the flange wall, but no sliding behavior was observed before significant concrete crushing. Furthermore, the measured vertical strain distribution revealed no obvious shear lag effect in the flange walls, indicating an evident spatial resisting mechanism of the specimen. Current design codes including NZS 3101:2006 (provisions for nominal strength), JGJ 3‐2010, and AIJ standard for the design and calculation of reinforced concrete box‐shaped wall structures underestimated the effective flange width of L‐shaped walls in the test core wall structure. When the core wall test substructure was subjected to DBE‐level and MCE‐level loading in one lateral direction, inducing compression in one coupled wall and tension in the other, the coupled wall under compression subsequently carried 63% and 86%, respectively, of the total base shear force during loading in the perpendicular lateral direction. Such a significant shear force redistribution among various coupled walls in a core wall should be taken into consideration in the design of tall buildings.Keywords
Funding Information
- National Natural Science Foundation of China (52425808)
This publication has 14 references indexed in Scilit:
- Seismic behavior and modeling of T‐shaped reinforced concrete walls under high axial force ratiosEarthquake Engineering & Structural Dynamics, 2023
- Behavior of double skin composite core wall subject to biaxial cyclic loadsEngineering Structures, 2023
- Out‐of‐plane shear‐axial failure in slender rectangular reinforced concrete wallsEarthquake Engineering & Structural Dynamics, 2022
- Seismic analysis of a modern 14‐story reinforced concrete core wall building system using the BTM‐shell methodologyEarthquake Engineering & Structural Dynamics, 2022
- Experimental and numerical study on the seismic performance of an L-shaped double-steel plate composite shear wallJournal of Building Engineering, 2022
- RC U-shaped walls subjected to in-plane, diagonal, and torsional loading: New experimental findingsEngineering Structures, 2021
- Impact of bi-directional loading on the seismic performance of C-shaped piers of core wallsEngineering Structures, 2020
- Behaviour of U-shaped RC walls under quasi-static cyclic diagonal loadingEngineering Structures, 2016
- A shear wall element for nonlinear seismic analysis of super-tall buildings using OpenSeesFinite Elements in Analysis and Design, 2015
- Seismic Design of Reinforced Concrete and Masonry Buildings1992