Xiaodong Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaodong Ji has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Xiang Gao
Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry Department of Civil Engineering Tsinghua University Beijing China
6 shared publicationsLei Sun
Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry Department of Civil Engineering Tsinghua University Beijing China
5 shared publicationsShaohui Zhang
Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry Department of Civil Engineering Tsinghua University Beijing China
5 shared publications- Yuncheng Zhuang
Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry Department of Civil Engineering Tsinghua University Beijing China
5 shared publications Jiaru Qian
Tsinghua University
4 shared publicationsYuhao Cheng
4 shared publications
Latest Publications
- 21 April 2026
- Published by SAGE Publications in Advances in Structural Engineering
Seismic control mechanism of tuned viscous mass damper (TVMD) outriggers
This study investigates the seismic control mechanism of tuned viscous mass damper (TVMD) outriggers in a core wall-frame system, which can be regarded as providing frequency-dependent equivalent stiffness and damping. Closed-form formulas for equivalent stiffness and damping of TVMD outriggers are derived based on a distributed-parameter model that represents the core-wall frame system. As the frequency increases, the equivalent stiffness transitions from negative to positive values and asymptotically decays to the spring stiffness of TVMD outriggers at infinite frequency. Simultaneously, the equivalent damping increases from the TVMD damping coefficient to a maximum value as the frequency increases from zero to the tuning frequency, and then asymptotically decays to zero along with the increasing frequency. A modal response mitigation ratio is defined and calculated, revealing that equivalent damping plays a dominant role over equivalent stiffness in the control mechanism. An analysis of equivalent damping-frequency curves elucidates that the control mechanism of TVMD outrigger, i.e., tuning effect for the targeted mode and damping supplement effect for the lower-order modes. Finally, seismic control performance of TVMD, viscous damper (VD), and negative stiffness damper (NSD) outriggers is compared based on a 140-m tall core wall-frame structure. Seismic response analysis demonstrates that TVMD, VD and NSD outriggers reduce the maximum inter-story drifts by 26%, 10%, and 17%, and the maximum floor accelerations by 27%, 12%, and 18%, respectively.
- 21 April 2026
- Published by SAGE Publications in Advances in Structural Engineering
Seismic control mechanism of tuned viscous mass damper (TVMD) outriggers
This study investigates the seismic control mechanism of tuned viscous mass damper (TVMD) outriggers in a core wall-frame system, which can be regarded as providing frequency-dependent equivalent stiffness and damping. Closed-form formulas for equivalent stiffness and damping of TVMD outriggers are derived based on a distributed-parameter model that represents the core-wall frame system. As the frequency increases, the equivalent stiffness transitions from negative to positive values and asymptotically decays to the spring stiffness of TVMD outriggers at infinite frequency. Simultaneously, the equivalent damping increases from the TVMD damping coefficient to a maximum value as the frequency increases from zero to the tuning frequency, and then asymptotically decays to zero along with the increasing frequency. A modal response mitigation ratio is defined and calculated, revealing that equivalent damping plays a dominant role over equivalent stiffness in the control mechanism. An analysis of equivalent damping-frequency curves elucidates that the control mechanism of TVMD outrigger, i.e., tuning effect for the targeted mode and damping supplement effect for the lower-order modes. Finally, seismic control performance of TVMD, viscous damper (VD), and negative stiffness damper (NSD) outriggers is compared based on a 140-m tall core wall-frame structure. Seismic response analysis demonstrates that TVMD, VD and NSD outriggers reduce the maximum inter-story drifts by 26%, 10%, and 17%, and the maximum floor accelerations by 27%, 12%, and 18%, respectively.
- 12 January 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (4) , 968-989
A Large‐Scale Test of a Reinforced Concrete Core Wall Subjected to Three‐Dimensional Loading
This paper presents a large‐scale quasi‐static test of a reinforced concrete (RC) core wall under high axial compression force and bidirectional lateral cyclic loads. A virtual 33‐story RC frame‐core wall prototype building was designed per the current Chinese codes, and RC core walls at the lower stories were selected as the substructure for experimental testing. Using a 108 MN spatial loading facility, three‐dimensional loading (including axial compressive force, bidirectional shear forces, and bidirectional overturning moments) was applied to the test structure to investigate the spatial resisting mechanism and seismic behavior of the core wall structure. During the test, the core wall specimen sustained brittle failure at 0.9% drift (corresponding to a top lateral drift of 1.34% for the 33‐story prototype structure) due to the large compressive strain demand (−0.008) in the unconfined region of flange walls. Out‐of‐plane diagonal compression cracks penetrated the entire sectional length of the flange wall, but no sliding behavior was observed before significant concrete crushing. Furthermore, the measured vertical strain distribution revealed no obvious shear lag effect in the flange walls, indicating an evident spatial resisting mechanism of the specimen. Current design codes including NZS 3101:2006 (provisions for nominal strength), JGJ 3‐2010, and AIJ standard for the design and calculation of reinforced concrete box‐shaped wall structures underestimated the effective flange width of L‐shaped walls in the test core wall structure. When the core wall test substructure was subjected to DBE‐level and MCE‐level loading in one lateral direction, inducing compression in one coupled wall and tension in the other, the coupled wall under compression subsequently carried 63% and 86%, respectively, of the total base shear force during loading in the perpendicular lateral direction. Such a significant shear force redistribution among various coupled walls in a core wall should be taken into consideration in the design of tall buildings.
- 12 January 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (4) , 968-989
A Large‐Scale Test of a Reinforced Concrete Core Wall Subjected to Three‐Dimensional Loading
This paper presents a large‐scale quasi‐static test of a reinforced concrete (RC) core wall under high axial compression force and bidirectional lateral cyclic loads. A virtual 33‐story RC frame‐core wall prototype building was designed per the current Chinese codes, and RC core walls at the lower stories were selected as the substructure for experimental testing. Using a 108 MN spatial loading facility, three‐dimensional loading (including axial compressive force, bidirectional shear forces, and bidirectional overturning moments) was applied to the test structure to investigate the spatial resisting mechanism and seismic behavior of the core wall structure. During the test, the core wall specimen sustained brittle failure at 0.9% drift (corresponding to a top lateral drift of 1.34% for the 33‐story prototype structure) due to the large compressive strain demand (−0.008) in the unconfined region of flange walls. Out‐of‐plane diagonal compression cracks penetrated the entire sectional length of the flange wall, but no sliding behavior was observed before significant concrete crushing. Furthermore, the measured vertical strain distribution revealed no obvious shear lag effect in the flange walls, indicating an evident spatial resisting mechanism of the specimen. Current design codes including NZS 3101:2006 (provisions for nominal strength), JGJ 3‐2010, and AIJ standard for the design and calculation of reinforced concrete box‐shaped wall structures underestimated the effective flange width of L‐shaped walls in the test core wall structure. When the core wall test substructure was subjected to DBE‐level and MCE‐level loading in one lateral direction, inducing compression in one coupled wall and tension in the other, the coupled wall under compression subsequently carried 63% and 86%, respectively, of the total base shear force during loading in the perpendicular lateral direction. Such a significant shear force redistribution among various coupled walls in a core wall should be taken into consideration in the design of tall buildings.
- 4 February 2025
- Published by Elsevier in Engineering Structures
- Vol. 329
Multi-sensor fusion for structural displacement estimation: Integrating vision and acceleration from mobile devices
- 4 February 2025
- Published by Elsevier in Engineering Structures
- Vol. 329
Multi-sensor fusion for structural displacement estimation: Integrating vision and acceleration from mobile devices
- 28 November 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (2) , 706-723
Seismic Behavior of a Stone Curtain Wall System With Undercut Bolt Anchorage Under Various Loading Protocols
This paper presents full‐scale experimental tests on the seismic behavior of a stone curtain wall system with undercut bolt anchorage (SCWS‐UBA). Experimental set‐ups were developed to test full‐scale stone curtain wall systems subjected to three loading protocols: quasi‐static in‐plane loading, dynamic in‐plane loading, and dynamic coupled in‐plane and out‐of‐plane loading. In all three tests, the SCWS‐UBA failed due to connector disengagement, followed by fracture of silicone sealant and transom‐to‐mullion connection welds and, finally, the falling out of stone panels. The SCWS‐UBA specimens exhibited a large displacement capacity with an ultimate falling‐out drift exceeding 3.0% in all tests. The drift ratio at connector disengagement was almost identical for both quasi‐static and dynamic in‐plane loading scenarios, indicating that in‐plane accelerations had a minimal impact on stone curtain wall failure. In addition, disengagement of the connector was dependent on the horizontal edge distance and vertical overlap depth between the connector and the L‐shaped steel angle. Simplified formulas for calculating the horizontal and vertical displacement of the connector were then developed. Based on these, seismic design recommendations were proposed for the overlap depth and edge distance between the connector and L‐shaped steel angle, thereby preventing the falling out of stone panels.
- 28 November 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (2) , 706-723
Seismic Behavior of a Stone Curtain Wall System With Undercut Bolt Anchorage Under Various Loading Protocols
This paper presents full‐scale experimental tests on the seismic behavior of a stone curtain wall system with undercut bolt anchorage (SCWS‐UBA). Experimental set‐ups were developed to test full‐scale stone curtain wall systems subjected to three loading protocols: quasi‐static in‐plane loading, dynamic in‐plane loading, and dynamic coupled in‐plane and out‐of‐plane loading. In all three tests, the SCWS‐UBA failed due to connector disengagement, followed by fracture of silicone sealant and transom‐to‐mullion connection welds and, finally, the falling out of stone panels. The SCWS‐UBA specimens exhibited a large displacement capacity with an ultimate falling‐out drift exceeding 3.0% in all tests. The drift ratio at connector disengagement was almost identical for both quasi‐static and dynamic in‐plane loading scenarios, indicating that in‐plane accelerations had a minimal impact on stone curtain wall failure. In addition, disengagement of the connector was dependent on the horizontal edge distance and vertical overlap depth between the connector and the L‐shaped steel angle. Simplified formulas for calculating the horizontal and vertical displacement of the connector were then developed. Based on these, seismic design recommendations were proposed for the overlap depth and edge distance between the connector and L‐shaped steel angle, thereby preventing the falling out of stone panels.
- 25 September 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (15) , 4670-4687
Shear behavior of reinforced concrete walls under variable axial tension‐compression and cyclic lateral loads
Under a strong earthquake, the axial force of shear walls in tall buildings may vary from compression to tension, but few studies have been conducted on this. Three low‐aspect‐ratio reinforced concrete (RC) wall specimens subjected to coupled variable axial tension‐compression and lateral load were tested in this study, to investigate the effect of the fluctuating range of axial force and loading histories on the shear behavior of RC walls. The test results indicated that shear‐compression failure occurred under the compressive‐shear loading for all test wall specimens, and no obvious post‐peak strength degradation in tension‐shear loading. The hysteretic curves of test wall specimens were strongly affected by the loading histories; the shear strength and deformation capacity were mainly affected by the fluctuation of axial forces, especially for tension‐shear strength. The equation of ACI 318‐19 and JGJ 3‐2010 conservatively predicted the shear strength of RC walls under the variable axial force, while the equation of ASCE/SEI 43‐05 accurately predicted the shear strength with the mean values of the VTest/VASCE of 0.97 and 0.94 for compression‐shear and tension‐shear strength, respectively. Comparison with an RC wall under constant axial tension revealed that the failure modes of RC walls were strongly dependent on the initial cracking patterns. Finally, a finite element (FE) model was developed, and parametric analyses were carried out to further estimate the effect of variable axial force on the cyclic shear behavior of RC walls.
- 25 September 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (15) , 4670-4687
Shear behavior of reinforced concrete walls under variable axial tension‐compression and cyclic lateral loads
Under a strong earthquake, the axial force of shear walls in tall buildings may vary from compression to tension, but few studies have been conducted on this. Three low‐aspect‐ratio reinforced concrete (RC) wall specimens subjected to coupled variable axial tension‐compression and lateral load were tested in this study, to investigate the effect of the fluctuating range of axial force and loading histories on the shear behavior of RC walls. The test results indicated that shear‐compression failure occurred under the compressive‐shear loading for all test wall specimens, and no obvious post‐peak strength degradation in tension‐shear loading. The hysteretic curves of test wall specimens were strongly affected by the loading histories; the shear strength and deformation capacity were mainly affected by the fluctuation of axial forces, especially for tension‐shear strength. The equation of ACI 318‐19 and JGJ 3‐2010 conservatively predicted the shear strength of RC walls under the variable axial force, while the equation of ASCE/SEI 43‐05 accurately predicted the shear strength with the mean values of the VTest/VASCE of 0.97 and 0.94 for compression‐shear and tension‐shear strength, respectively. Comparison with an RC wall under constant axial tension revealed that the failure modes of RC walls were strongly dependent on the initial cracking patterns. Finally, a finite element (FE) model was developed, and parametric analyses were carried out to further estimate the effect of variable axial force on the cyclic shear behavior of RC walls.
- 31 May 2024
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 218
A substructural shake table testing method for full-scale nonstructural elements
- 31 May 2024
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 218
A substructural shake table testing method for full-scale nonstructural elements
- 30 April 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (9) , 2827-2849
Evaluation of strength and stiffness degradation of RC shear walls: An integrated image processing and deep learning approach
- 30 April 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (9) , 2827-2849
Evaluation of strength and stiffness degradation of RC shear walls: An integrated image processing and deep learning approach