IMPROVED ACTIVE FILTER PERFORMANCE IN SINGLE-PHASE CONTROLLED RECTIFIERS WITH PULSE WIDTH MODULATION (PWM) CONTROL
Author:
Open Access
- 30 April 2023
- journal article
- research article
- Published by Universitas Nusa Cendana in Jurnal Media Elektro
- p. 19-28
Abstract
Various commutation techniques, such as forced commutation, ignition angle control, and symmetrical angle control, have been developed to improve the input power factor and harmonic level. However, all of these techniques will produce only one pulse per half cycle of the converter input current, and consequently, the lowest order harmonic is the third harmonic. A comparative study of active filter converters between single pulse and PWM control has been investigated. Both converters are given identical R and RL loads to compare power factor (PF) and Total Harmonic Distortion (THD). The method used is a simulation with the PSPICE program. The performance of both rectifiers is evaluated based on the input current waveform, THD, and PF. At RL load, the input current distortion decreases drastically, with a THD of 100.67%. In PWM control, harmonics are reduced with a THD of 25.48%. The rectifier power factor in the active filter obtained PF of 0.25, whereas in PWM control, PF increased by 0.65.Keywords
This publication has 17 references indexed in Scilit:
- Phase control thyristor based soft-starter for a grid connected induction generator for wind turbine system2010
- Active power filter based on three-phase two-leg switch-clamped inverterElectric Power Systems Research, 2004
- Optimal harmonic injection in thyristor rectifier for power factor correctionIEE Proceedings - Electric Power Applications, 2003
- Optimization method to design filters for harmonic current reduction in a three phase rectifier2002
- Review of high-performance three-phase power-factor correction circuitsIEEE Transactions on Industrial Electronics, 1997
- Hybrid solutions for improving passive filter performance in high power applicationsIEEE Transactions on Industry Applications, 1997
- A new power line conditioner for harmonic compensation in power systemsIEEE Transactions on Power Delivery, 1995
- Single-switch three-phase power factor preregulator under variable switching frequency and discontinuous input current1993
- Analysis and design of an active power filter using quad-series voltage source PWM convertersIEEE Transactions on Industry Applications, 1990
- A new approach to harmonic compensation in power systems-a combined system of shunt passive and series active filtersIEEE Transactions on Industry Applications, 1990