Sudirman Syam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sudirman Syam has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Sri Kurniati
Universitas Nusa Cendana
51 shared publicationsRuslan Ramang
11 shared publicationsJauhari Effendi
9 shared publications- Nursalim Nursalim
Universitas Nusa Cendana
7 shared publications - Sri Kurniati
Department of Electrical Engineering, Faculty of Science and Technology, Nusa Cendana University, Kupang-NTT, 85228, Indonesia
7 shared publications - Sudjito Soeparman
Mechanical Engineering Department, Engineering Faculty, Brawijaya University, Malang 65145, Indonesia
4 shared publications
Latest Publications
- Open Access
- 1 March 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16 (1) , 555-563
Experimental study on the use of Savonius combined blade rotors as wind turbines and hydrokinetic turbines
Renewable energy development is increasingly important to anticipate the limited use of fossil energy and its impact on the environment. The Savonius turbine is a vertical axis turbine that can utilize flow from all directions with simple construction, so it has the potential to be developed as a wind turbine and hydrokinetic to generate electricity. This paper aims to conduct an experimental studied the same Savonius combined blade rotor as a wind turbine used in a wind tunnel and a hydrokinetic turbine in an irrigation channel. The experimental results show that the Savonius turbine can function well as a wind and hydrokinetic turbine. The Savonius combined blade turbine improves the performance of conventional Savonius blade turbines, including its use as a hydrokinetic turbine, which is affected by flow velocity. The performance of the Savonius turbine is indicated by the power coefficient Cp and torque coefficient (Ct) values based on the fluid flow velocity. At the same wind speed (4 m/s), the combined blades can increase the performance Cp by up to 11% compared to conventional blades. The use of the same combined blades tested as a hydrokinetic turbine resulted in an increase in Cp and a decrease in Ct with an increase in tip speed ratio (TSR).
- 1 March 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16 (1) , 555-563
Open AccessExperimental study on the use of Savonius combined blade rotors as wind turbines and hydrokinetic turbines
Renewable energy development is increasingly important to anticipate the limited use of fossil energy and its impact on the environment. The Savonius turbine is a vertical axis turbine that can utilize flow from all directions with simple construction, so it has the potential to be developed as a wind turbine and hydrokinetic to generate electricity. This paper aims to conduct an experimental studied the same Savonius combined blade rotor as a wind turbine used in a wind tunnel and a hydrokinetic turbine in an irrigation channel. The experimental results show that the Savonius turbine can function well as a wind and hydrokinetic turbine. The Savonius combined blade turbine improves the performance of conventional Savonius blade turbines, including its use as a hydrokinetic turbine, which is affected by flow velocity. The performance of the Savonius turbine is indicated by the power coefficient Cp and torque coefficient (Ct) values based on the fluid flow velocity. At the same wind speed (4 m/s), the combined blades can increase the performance Cp by up to 11% compared to conventional blades. The use of the same combined blades tested as a hydrokinetic turbine resulted in an increase in Cp and a decrease in Ct with an increase in tip speed ratio (TSR).
- Open Access
- 2 September 2024
- Published by Acadlore Publishing Services Limited in Journal of Sustainability for Energy
- Vol. 3 (3) , 171-186
Prediction and Assessment of Solar Radiation Intensity Shade Projection in Jayapura City, Indonesia: Optimisation of Solar Energy Utilisation
Jayapura City, Indonesia, presents significant potential for solar energy utilisation, driven by its high solar radiation levels. However, the presence of urban obstacles, such as buildings, trees, and varied topography, can obstruct the direct transmission of solar radiation to the ground, thereby reducing its efficiency for solar energy systems. This study aims to develop a methodology for predicting and assessing the shade projection of solar radiation intensity across Jayapura City. A quantitative descriptive approach was employed, involving the measurement of elevation and azimuth angles using Global Positioning System (GPS) technology. Data were analysed using RETScreen and Sun Locator Pro (SLP) software. The analysis of the collected data facilitated the generation of a detailed shade projection map, which can be utilised to optimise the placement of solar panels and enhance the performance of the city's Solar Power Generation System (SPGS). The findings indicated that the highest elevation angle occurred at 12:00 pm in March. In September, the sun's position was nearly directly above the equator, leading to a minimal shadow ratio (SR = 0.08), with the projection closely aligned with the object. The azimuth angle, measured at noon, exhibited an extreme angular shift, reflecting the standard reference towards the north (180° at noon). This study demonstrates the potential of this methodology to inform the strategic placement of solar infrastructure, improving the efficiency and efficacy of solar power systems in urban environments characterised by complex topographies.
- 2 September 2024
- Published by Acadlore Publishing Services Limited in Journal of Sustainability for Energy
- Vol. 3 (3) , 171-186
Open AccessPrediction and Assessment of Solar Radiation Intensity Shade Projection in Jayapura City, Indonesia: Optimisation of Solar Energy Utilisation
Jayapura City, Indonesia, presents significant potential for solar energy utilisation, driven by its high solar radiation levels. However, the presence of urban obstacles, such as buildings, trees, and varied topography, can obstruct the direct transmission of solar radiation to the ground, thereby reducing its efficiency for solar energy systems. This study aims to develop a methodology for predicting and assessing the shade projection of solar radiation intensity across Jayapura City. A quantitative descriptive approach was employed, involving the measurement of elevation and azimuth angles using Global Positioning System (GPS) technology. Data were analysed using RETScreen and Sun Locator Pro (SLP) software. The analysis of the collected data facilitated the generation of a detailed shade projection map, which can be utilised to optimise the placement of solar panels and enhance the performance of the city's Solar Power Generation System (SPGS). The findings indicated that the highest elevation angle occurred at 12:00 pm in March. In September, the sun's position was nearly directly above the equator, leading to a minimal shadow ratio (SR = 0.08), with the projection closely aligned with the object. The azimuth angle, measured at noon, exhibited an extreme angular shift, reflecting the standard reference towards the north (180° at noon). This study demonstrates the potential of this methodology to inform the strategic placement of solar infrastructure, improving the efficiency and efficacy of solar power systems in urban environments characterised by complex topographies.
- Open Access
- 30 June 2024
- Published by Acadlore Publishing Services Limited in Journal of Intelligent Systems and Control
- Vol. 3 (2) , 107-120
Comparison of Fuzzy Logic Controllers for Speed Regulation in Separately Excited DC Motors: Field Versus Armature Control
Separately excited direct current (DC) motors, renowned for their linear characteristics and controllability, are extensively employed in various industrial applications. Effective speed control of these motors can be achieved through multiple methods, with fuzzy logic being a particularly robust approach. This study focuses on evaluating the transient responses of current and voltage in relation to the rotational speed of a DC motor under two distinct control schemes: field control and armature control, both subjected to similar load disturbances. A simulation-based methodology was employed using a DC motor speed control system combined with a fuzzy logic controller (FLC) designed with the Mamdani min-max method. The system was implemented in Simulink. In this framework, the FLC processes speed error signals and field current (I f) errors as inputs to generate a field voltage control signal, which is then utilized by the armature voltage (Va) regulator to modulate the armature voltage. The results demonstrate that the FLC effectively stabilizes motor speed, quickly and accurately following speed references, even under load disturbances. Moreover, the system effectively mitigates speed fluctuations induced by load variations. A comparison between the two control schemes reveals that the field control approach exhibits a slower response time, taking 2.93 seconds to reach a steady state, whereas the armature control achieves this in a significantly faster time of 0.144 seconds. These findings underscore the efficacy of fuzzy logic in maintaining stable and responsive speed control in DC motors, with the armature control method displaying superior transient performance.
- 30 June 2024
- Published by Acadlore Publishing Services Limited in Journal of Intelligent Systems and Control
- Vol. 3 (2) , 107-120
Open AccessComparison of Fuzzy Logic Controllers for Speed Regulation in Separately Excited DC Motors: Field Versus Armature Control
Separately excited direct current (DC) motors, renowned for their linear characteristics and controllability, are extensively employed in various industrial applications. Effective speed control of these motors can be achieved through multiple methods, with fuzzy logic being a particularly robust approach. This study focuses on evaluating the transient responses of current and voltage in relation to the rotational speed of a DC motor under two distinct control schemes: field control and armature control, both subjected to similar load disturbances. A simulation-based methodology was employed using a DC motor speed control system combined with a fuzzy logic controller (FLC) designed with the Mamdani min-max method. The system was implemented in Simulink. In this framework, the FLC processes speed error signals and field current (I f) errors as inputs to generate a field voltage control signal, which is then utilized by the armature voltage (Va) regulator to modulate the armature voltage. The results demonstrate that the FLC effectively stabilizes motor speed, quickly and accurately following speed references, even under load disturbances. Moreover, the system effectively mitigates speed fluctuations induced by load variations. A comparison between the two control schemes reveals that the field control approach exhibits a slower response time, taking 2.93 seconds to reach a steady state, whereas the armature control achieves this in a significantly faster time of 0.144 seconds. These findings underscore the efficacy of fuzzy logic in maintaining stable and responsive speed control in DC motors, with the armature control method displaying superior transient performance.
- Open Access
- 30 June 2024
- Published by Universitas Nusa Cendana in Jurnal Pengabdian Kepada Masyarakat Undana
- p. 16-23
PELATIHAN PENGGULUNGAN TRAFO BAGI MAHASISWA TEKNIK ELEKTRO UNIVERSITAS NUSA CENDANA
Kegiatan ini bertujuan untuk meningkatkan keterampilan dan kompetensi sumber daya manusia (SDM) melalui pemberian keterampilan penggulungan trafo bagi mahasiswa Teknik Elektro. Metode yang digunakan adalah melalui ceramah dan tanya jawab berupa pemberian teori-teori trafo, pengenalan alat ukur, dan cara menghitung belitan dan menggulung trafo. Metode berikutnya adalah melalui demonstrasi dan praktek langsung berupa pengenalan nama alat pengukuran diameter kawat email, besi keren, cara mempergunakan alat penggulungan trafo, dan teknik menyolder. Model pembelajaran dilakukan berupa 30% teori dan 70% praktek. Hasil kegiatan menunjukkan pemberian keterampilan ini sangat efektif dan efisien dalam meningkatkan skill dan keterampilan mahasiswa. Pemberian keterampilan ini diberikan selama 2 minggu dan hasilnya menunjukkan 90% dapat memahami teori dan 70% dapat memahami praktek.
- 30 June 2024
- Published by Universitas Nusa Cendana in Jurnal Pengabdian Kepada Masyarakat Undana
- p. 16-23
Open AccessPELATIHAN PENGGULUNGAN TRAFO BAGI MAHASISWA TEKNIK ELEKTRO UNIVERSITAS NUSA CENDANA
Kegiatan ini bertujuan untuk meningkatkan keterampilan dan kompetensi sumber daya manusia (SDM) melalui pemberian keterampilan penggulungan trafo bagi mahasiswa Teknik Elektro. Metode yang digunakan adalah melalui ceramah dan tanya jawab berupa pemberian teori-teori trafo, pengenalan alat ukur, dan cara menghitung belitan dan menggulung trafo. Metode berikutnya adalah melalui demonstrasi dan praktek langsung berupa pengenalan nama alat pengukuran diameter kawat email, besi keren, cara mempergunakan alat penggulungan trafo, dan teknik menyolder. Model pembelajaran dilakukan berupa 30% teori dan 70% praktek. Hasil kegiatan menunjukkan pemberian keterampilan ini sangat efektif dan efisien dalam meningkatkan skill dan keterampilan mahasiswa. Pemberian keterampilan ini diberikan selama 2 minggu dan hasilnya menunjukkan 90% dapat memahami teori dan 70% dapat memahami praktek.
- Open Access
- 21 March 2024
- Published by Acadlore Publishing Services Limited in Journal of Sustainability for Energy
- Vol. 3 (1) , 21-29
Enhancing Biodiesel Production from Nyamplung Oil: Kinetic Analysis of Transesterification via Electromagnetic Induction Heating
In the quest for sustainable and environmentally friendly biofuels, Calophyllum inophyllum L., commonly known as Nyamplung, presents a promising feedstock due to its high oil content (75%) and a significant proportion of unsaturated fatty acids (approximately 71%). Notably, the oil extracted from this species exhibits higher viscosity and reduced capillarity compared to conventional kerosene, posing unique challenges for biodiesel conversion. This study explores the efficacy of electromagnetic induction heating as a novel transesterification method to produce biodiesel from Nyamplung oil. The process was optimized across a range of temperatures (45-65°C), reaction times (0.43-1.03 minutes), methanol to oil molar ratios (6:1), and a catalyst concentration of KOH at 2% of the total weight of oil and methanol. The conversion of Nyamplung oil into biodiesel was primarily assessed through the formation of methyl esters, with Gas Chromatography-Mass Spectrometry (GC-MS) employed for analytical verification. A comprehensive kinetic analysis revealed a transesterification reaction rate constant of rT=6.46×1014e(-1,068.93/RT) [ME], indicating an activation energy requirement of 1,068 kJ/mol at the operational peak temperature of 65°C. This activation energy is notably lower than that observed with microwave heating, suggesting electromagnetic induction as a more efficient heating mechanism for this reaction. The findings underscore the potential of electromagnetic induction heating in enhancing the conversion efficiency of high-viscosity feedstocks like Nyamplung oil into biodiesel, offering a promising avenue for the production of renewable energy sources. The detailed evaluation of reaction kinetics and activation energies within this study not only contributes to the optimization of biodiesel production processes but also reinforces the viability of Calophyllum inophyllum L. as a sustainable biofuel precursor.
- 21 March 2024
- Published by Acadlore Publishing Services Limited in Journal of Sustainability for Energy
- Vol. 3 (1) , 21-29
Open AccessEnhancing Biodiesel Production from Nyamplung Oil: Kinetic Analysis of Transesterification via Electromagnetic Induction Heating
In the quest for sustainable and environmentally friendly biofuels, Calophyllum inophyllum L., commonly known as Nyamplung, presents a promising feedstock due to its high oil content (75%) and a significant proportion of unsaturated fatty acids (approximately 71%). Notably, the oil extracted from this species exhibits higher viscosity and reduced capillarity compared to conventional kerosene, posing unique challenges for biodiesel conversion. This study explores the efficacy of electromagnetic induction heating as a novel transesterification method to produce biodiesel from Nyamplung oil. The process was optimized across a range of temperatures (45-65°C), reaction times (0.43-1.03 minutes), methanol to oil molar ratios (6:1), and a catalyst concentration of KOH at 2% of the total weight of oil and methanol. The conversion of Nyamplung oil into biodiesel was primarily assessed through the formation of methyl esters, with Gas Chromatography-Mass Spectrometry (GC-MS) employed for analytical verification. A comprehensive kinetic analysis revealed a transesterification reaction rate constant of rT=6.46×1014e(-1,068.93/RT) [ME], indicating an activation energy requirement of 1,068 kJ/mol at the operational peak temperature of 65°C. This activation energy is notably lower than that observed with microwave heating, suggesting electromagnetic induction as a more efficient heating mechanism for this reaction. The findings underscore the potential of electromagnetic induction heating in enhancing the conversion efficiency of high-viscosity feedstocks like Nyamplung oil into biodiesel, offering a promising avenue for the production of renewable energy sources. The detailed evaluation of reaction kinetics and activation energies within this study not only contributes to the optimization of biodiesel production processes but also reinforces the viability of Calophyllum inophyllum L. as a sustainable biofuel precursor.
- Open Access
- 30 October 2023
- Published by Universitas Nusa Cendana in Jurnal Media Elektro
- p. 120-127
PERANCANGAN SISTEM PENGISI TOKEN LISTRIK BERUMPAN BALIK PADA kWh METER PRABAYAR BERBASIS ARDUINO
Kilo Watt Hour Meter or kWh meter is a tool for calculating the amount of electrical energy used by electricity consumers, both residential and industrial customers. The electrical energy used is then converted into the electricity price that must be paid each month. Currently, most kWh meters in circulation are smart kWh, which use electricity tokens as transaction calculations. Customers must fill in 20 token numbers via the kWh meter keypad to fill in electricity tokens. Filling in this 20-digit token is not easy, this is because usually, this type of kWh is placed in a higher place to avoid the reach of children. This placement sometimes causes problems with replenishing the token, and users must start over from the beginning. This research aims to create a tool to fill in electricity token numbers that can be controlled using an Android application, making it easier for users to fill in electricity tokens remotely via smartphone. Apart from that, this system has feedback in the form of notifications that display numbers that failed to be filled in on the kWh meter. Test results show that this system can function well from 10 meters without obstructions and 9 meters without obstructions.
- 30 October 2023
- Published by Universitas Nusa Cendana in Jurnal Media Elektro
- p. 120-127
Open AccessPERANCANGAN SISTEM PENGISI TOKEN LISTRIK BERUMPAN BALIK PADA kWh METER PRABAYAR BERBASIS ARDUINO
Kilo Watt Hour Meter or kWh meter is a tool for calculating the amount of electrical energy used by electricity consumers, both residential and industrial customers. The electrical energy used is then converted into the electricity price that must be paid each month. Currently, most kWh meters in circulation are smart kWh, which use electricity tokens as transaction calculations. Customers must fill in 20 token numbers via the kWh meter keypad to fill in electricity tokens. Filling in this 20-digit token is not easy, this is because usually, this type of kWh is placed in a higher place to avoid the reach of children. This placement sometimes causes problems with replenishing the token, and users must start over from the beginning. This research aims to create a tool to fill in electricity token numbers that can be controlled using an Android application, making it easier for users to fill in electricity tokens remotely via smartphone. Apart from that, this system has feedback in the form of notifications that display numbers that failed to be filled in on the kWh meter. Test results show that this system can function well from 10 meters without obstructions and 9 meters without obstructions.
- Open Access
- 30 April 2023
- Published by Universitas Nusa Cendana in Jurnal Media Elektro
- p. 19-28
IMPROVED ACTIVE FILTER PERFORMANCE IN SINGLE-PHASE CONTROLLED RECTIFIERS WITH PULSE WIDTH MODULATION (PWM) CONTROL
Various commutation techniques, such as forced commutation, ignition angle control, and symmetrical angle control, have been developed to improve the input power factor and harmonic level. However, all of these techniques will produce only one pulse per half cycle of the converter input current, and consequently, the lowest order harmonic is the third harmonic. A comparative study of active filter converters between single pulse and PWM control has been investigated. Both converters are given identical R and RL loads to compare power factor (PF) and Total Harmonic Distortion (THD). The method used is a simulation with the PSPICE program. The performance of both rectifiers is evaluated based on the input current waveform, THD, and PF. At RL load, the input current distortion decreases drastically, with a THD of 100.67%. In PWM control, harmonics are reduced with a THD of 25.48%. The rectifier power factor in the active filter obtained PF of 0.25, whereas in PWM control, PF increased by 0.65.
- 30 April 2023
- Published by Universitas Nusa Cendana in Jurnal Media Elektro
- p. 19-28
Open AccessIMPROVED ACTIVE FILTER PERFORMANCE IN SINGLE-PHASE CONTROLLED RECTIFIERS WITH PULSE WIDTH MODULATION (PWM) CONTROL
Various commutation techniques, such as forced commutation, ignition angle control, and symmetrical angle control, have been developed to improve the input power factor and harmonic level. However, all of these techniques will produce only one pulse per half cycle of the converter input current, and consequently, the lowest order harmonic is the third harmonic. A comparative study of active filter converters between single pulse and PWM control has been investigated. Both converters are given identical R and RL loads to compare power factor (PF) and Total Harmonic Distortion (THD). The method used is a simulation with the PSPICE program. The performance of both rectifiers is evaluated based on the input current waveform, THD, and PF. At RL load, the input current distortion decreases drastically, with a THD of 100.67%. In PWM control, harmonics are reduced with a THD of 25.48%. The rectifier power factor in the active filter obtained PF of 0.25, whereas in PWM control, PF increased by 0.65.
- Open Access
- 15 April 2023
- Published by Center for Open Science in OSF Preprints
Optimasi Penempatan Kapasitor Shunt sebagai Usaha untuk Memperbaiki Kualitas Jaringan Listrik pada Sistem Distribusi PLN (Persero) kota Kupang Dengan Menggunakan Algoritma Genetika
Dalam perencanaan pengoperasian dan pengendalian sistem tenaga listrik muncul berbagai persoalan teknis maupun ekonomis, salah satunya diakibatkan oleh beban sistem yang dinamis. Di sisi lain energi listrik tidak dapat disimpan dalam jumlah banyak sehingga harus disediakan pada saat dibutuhkan oleh konsumen, akibatnya timbul persoalan dalam menghadapi kebutuhan daya listrik yang berubah dari waktu ke waktu. Dalam mengoperasikan sistem tenaga listrik ditemui berbagai persoalan yang dapat menimbulkan penurunan kualitas serta kelangsungan supplay daya listrik ke beban. Berkaitan dengan persoalan tersebut, maka hilangnya daya aktif (losses) merupakan salah satu kasus yang selalu muncul pada penyaluran tenaga listrik pada jaringan transmisi atau distribusi tenaga listrik. Kasus ini muncul sebagai akibat adanya resistansi dan kenaikan temperatur ketika suatu konduktor dialiri arus listrik. Resistansi sendiri dipengaruhi oleh jenis penghantar, panjang penghantar, dan diameter penghantar. Selain dari pada itu resistansi juga dipengaruhi oleh temperatur penghantar dan frekuensi arus yang melewatinya.Analisis studi aliran daya dilakukan pada 6 penyulang, yakni penyulang tompello, penyulang walikota, penyulang Tingkat I, penyulang Tabulolong, penyulang Penfui, dan penyulang Oebufu pada sistem distribusi kota Kupang dengan menggunakan metode Newton-Raphson. Berdasarkan hasil analisis studi aliran daya ini diperoleh informasi bahwa penyulang Tingkat I mempunyai persentase rugi daya aktif yang paling kecil, yakni 0,189%, sedangkan penyulang Penfui mempunyai persentase rugi daya aktif yang paling besar, yakni 1, 82%. Selanjutnya hasil analisis jatuh tegangan diketahui bahwa penyulang Penfui mempunyai persentase jatuh tegangan yang paling besar yakni 3,205%, sedangkan pada penyulang lainnya masing masing masing diperoleh, penyulang Tompello = 0,520%, penyulang walikota 1,577%, penyulang tingkat I = 0,520, penyulang Tabulolong = 2,006%, dan penyulang Oebufu = 2, 723%.
- 15 April 2023
- Published by Center for Open Science in OSF Preprints
Open AccessOptimasi Penempatan Kapasitor Shunt sebagai Usaha untuk Memperbaiki Kualitas Jaringan Listrik pada Sistem Distribusi PLN (Persero) kota Kupang Dengan Menggunakan Algoritma Genetika
Dalam perencanaan pengoperasian dan pengendalian sistem tenaga listrik muncul berbagai persoalan teknis maupun ekonomis, salah satunya diakibatkan oleh beban sistem yang dinamis. Di sisi lain energi listrik tidak dapat disimpan dalam jumlah banyak sehingga harus disediakan pada saat dibutuhkan oleh konsumen, akibatnya timbul persoalan dalam menghadapi kebutuhan daya listrik yang berubah dari waktu ke waktu. Dalam mengoperasikan sistem tenaga listrik ditemui berbagai persoalan yang dapat menimbulkan penurunan kualitas serta kelangsungan supplay daya listrik ke beban. Berkaitan dengan persoalan tersebut, maka hilangnya daya aktif (losses) merupakan salah satu kasus yang selalu muncul pada penyaluran tenaga listrik pada jaringan transmisi atau distribusi tenaga listrik. Kasus ini muncul sebagai akibat adanya resistansi dan kenaikan temperatur ketika suatu konduktor dialiri arus listrik. Resistansi sendiri dipengaruhi oleh jenis penghantar, panjang penghantar, dan diameter penghantar. Selain dari pada itu resistansi juga dipengaruhi oleh temperatur penghantar dan frekuensi arus yang melewatinya.Analisis studi aliran daya dilakukan pada 6 penyulang, yakni penyulang tompello, penyulang walikota, penyulang Tingkat I, penyulang Tabulolong, penyulang Penfui, dan penyulang Oebufu pada sistem distribusi kota Kupang dengan menggunakan metode Newton-Raphson. Berdasarkan hasil analisis studi aliran daya ini diperoleh informasi bahwa penyulang Tingkat I mempunyai persentase rugi daya aktif yang paling kecil, yakni 0,189%, sedangkan penyulang Penfui mempunyai persentase rugi daya aktif yang paling besar, yakni 1, 82%. Selanjutnya hasil analisis jatuh tegangan diketahui bahwa penyulang Penfui mempunyai persentase jatuh tegangan yang paling besar yakni 3,205%, sedangkan pada penyulang lainnya masing masing masing diperoleh, penyulang Tompello = 0,520%, penyulang walikota 1,577%, penyulang tingkat I = 0,520, penyulang Tabulolong = 2,006%, dan penyulang Oebufu = 2, 723%.
- Open Access
- 7 February 2023
- Published by Center for Open Science in OSF Preprints
PENGEMBANGAN DESAIN TURBIN SAVONIUS YANG TERINTEGRASI DENGAN GENERATOR AXIAL TANPA GEAR (GEARLESS)
Turbin savonius merupakan tipe turbin kecepatan angin rendah dengan menghasilkan torsi besar sangat cocok untuk dimanfaatkan sebagai tenaga penggerak sistem pompa, irigasi tambak, atau peralatan pengolahan hasil pertanian. Turbin angin Savonius merupakan perangkat sumbu vertikal sederhana berbentuk setengah silinder yang terpasang pada sisi berlawanan dari poros vertikal dan beroperasi pada gaya tarik, sehingga tidak dapat berputar lebih cepat dari kecepatan angin. Saat angin bertiup menuju ke permukaan blade yang berlawanan (satu cembung dan cekung lainnya), dua gaya yang berbeda (tarik dan angkat) diberikan pada dua permukaan tersebut. Oleh karena itu, efisiensi dari turbin menjadi rendah karena beberapa faktor. Pada ujung rotor blade terdapat satu plate/piringan yang menghubungkan 2 blade turbin yang disebut end-plate. Saat ini belum ada penelitian yang memanfaatkan fungsi lain dari end-plate ini. Selain itu, masih sedikit penelitian yang dilakukan untuk menvariasikan sudu-sudu rotor profil blade.
- 7 February 2023
- Published by Center for Open Science in OSF Preprints
Open AccessPENGEMBANGAN DESAIN TURBIN SAVONIUS YANG TERINTEGRASI DENGAN GENERATOR AXIAL TANPA GEAR (GEARLESS)
Turbin savonius merupakan tipe turbin kecepatan angin rendah dengan menghasilkan torsi besar sangat cocok untuk dimanfaatkan sebagai tenaga penggerak sistem pompa, irigasi tambak, atau peralatan pengolahan hasil pertanian. Turbin angin Savonius merupakan perangkat sumbu vertikal sederhana berbentuk setengah silinder yang terpasang pada sisi berlawanan dari poros vertikal dan beroperasi pada gaya tarik, sehingga tidak dapat berputar lebih cepat dari kecepatan angin. Saat angin bertiup menuju ke permukaan blade yang berlawanan (satu cembung dan cekung lainnya), dua gaya yang berbeda (tarik dan angkat) diberikan pada dua permukaan tersebut. Oleh karena itu, efisiensi dari turbin menjadi rendah karena beberapa faktor. Pada ujung rotor blade terdapat satu plate/piringan yang menghubungkan 2 blade turbin yang disebut end-plate. Saat ini belum ada penelitian yang memanfaatkan fungsi lain dari end-plate ini. Selain itu, masih sedikit penelitian yang dilakukan untuk menvariasikan sudu-sudu rotor profil blade.
- Open Access
- 5 February 2023
- Published by Center for Open Science in OSF Preprints
MOTOR MAGNET DENGAN MENGGUNAKAN MAGNET PERMANEN NdFeb PERSEGI PANJANG YANG DISUSUN SECARA BERLAPIS
Invensi ini berhubungan dengan motor magnet yang mempunyai torsi tinggi. Adanya penggunaan magnet NdFeb persegi panjang yang disusun secara berlapis dapat meningkatkan fluks magnetik. Peningkatan fluks magnetik dari gigi magnet sesuai dengan teori hukum ohm yang berlaku dalam teori rangkaian listrik yang identik dengan rangkaian magnetik. Adanya penyusunan magnet secara berlapis atau disusun secara paralel akan berdampak pada penurunan nilai reluktansi magnetik yang berbanding terbalik dengan adanya peningkatan fluks magnetik. Invensi dari motor magnet yang menggunakan lapisan magnet persegipanjang ini dapat mengurangi penggunaan magnet NdFeb yang dapat menggantikan magnet berbentuk sektoral. Selain itu, pembuatan motor magnet ini lebih murah, dan bentuknya lebih sederhana dibanding dengan motor magnet yang telah dibuat sebelumnya.
- 5 February 2023
- Published by Center for Open Science in OSF Preprints
Open AccessMOTOR MAGNET DENGAN MENGGUNAKAN MAGNET PERMANEN NdFeb PERSEGI PANJANG YANG DISUSUN SECARA BERLAPIS
Invensi ini berhubungan dengan motor magnet yang mempunyai torsi tinggi. Adanya penggunaan magnet NdFeb persegi panjang yang disusun secara berlapis dapat meningkatkan fluks magnetik. Peningkatan fluks magnetik dari gigi magnet sesuai dengan teori hukum ohm yang berlaku dalam teori rangkaian listrik yang identik dengan rangkaian magnetik. Adanya penyusunan magnet secara berlapis atau disusun secara paralel akan berdampak pada penurunan nilai reluktansi magnetik yang berbanding terbalik dengan adanya peningkatan fluks magnetik. Invensi dari motor magnet yang menggunakan lapisan magnet persegipanjang ini dapat mengurangi penggunaan magnet NdFeb yang dapat menggantikan magnet berbentuk sektoral. Selain itu, pembuatan motor magnet ini lebih murah, dan bentuknya lebih sederhana dibanding dengan motor magnet yang telah dibuat sebelumnya.