Pyrohydrolysis Coupled to Ion Chromatography for Sensitive Determination of Iodine in Food-Related Materials
Authors:
- 21 February 2012
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 45 (8) , 862-871
Abstract
For the determination of iodine in food-related materials, the biological sample was decomposed using a pyrohydrolytic procedure. A sample vessel made from mullite, in which an aliquot of sample was taken, was placed in a quartz tube, and heated at 100°C through 820°C step by step under wet oxygen flow. Iodine in the sample was separated by evaporation as hydrogen iodide and collected in a dilute sodium hydroxide solution. After the basic solution containing the analyte was neutralized by adding hydrochloric acid, iodine in the solution was determined by using ion chromatography with ultraviolet absorption detection. The operating conditions for the pyrohydrolytic decomposition procedure were examined. Under the optimized conditions, organic constituents in the sample were completely decomposed since the analyte species were converted to the iodide ion. The detection limit of 0.01 µg g−1 iodine was established with a reproducibility of 1.2% when a sample of 500 mg was taken. This method was applied to the determination of iodine in various certified reference materials and food samples with satisfactory results.Keywords
This publication has 17 references indexed in Scilit:
- Determination of chlorine, bromine and iodine in plant samples by inductively coupled plasma-mass spectrometry after leaching with tetramethyl ammonium hydroxide under a mild temperature conditionAnalytica Chimica Acta, 2006
- Sensitive determination of iodine by tungsten boat furnace vaporization with inductively coupled plasma mass spectrometry using tetramethylammonium hydroxide as a chemical modifierRapid Communications in Mass Spectrometry, 2004
- Determination of 129I/127I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cellJournal of Analytical Atomic Spectrometry, 2003
- Chemiluminescence determination of iodide and/or iodine using a luminol–hexadecyltrimethylammonium chloride reversed micelle system following on-line oxidation and extractionThe Analyst, 2000
- Investigation of problems associated with the determination of iodine in glacial acetic acid samples using flow injection analysis-inductively coupled plasma-mass spectrometry†Analytical Communications, 1999
- The distribution of iodine in the earth's crustChemical Geology, 1998
- Rapid determination of trace phosphorus, sulfur, chlorine, bromine and iodine by energy dispersive X-ray fluorescence analysis with monochromatic excitations.BUNSEKI KAGAKU, 1998
- Determination of Iodine in Food-related Certified Reference Materials Using Wet Ashing and Detection by Inductively Coupled Plasma Mass SpectrometryJournal of Analytical Atomic Spectrometry, 1997
- Determination of halogens, with special reference to iodine, in geological and biological samples using pyrohydrolysis for preparation and inductively coupled plasma mass spectrometry and ion chromatography for measurementThe Analyst, 1996
- Determination of Iodine in Foods by High Performance Liquid Chromatography with Electrochemical DetectionFood Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi), 1994