Independent evaluation of an in‐house brachytherapy treatment planning system using simulation, measurement and calculation methods
Open Access
- 8 March 2012
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 13 (2) , 103-112
Abstract
Accuracy of treatment planning systems may significantly influence the efficacy of brachytherapy. The purpose of this work is a detailed, varied and independent evaluation of an in-house brachytherapy treatment planning software called STPS. Operational accuracy of STPS was investigated. Geometric tests were performed to validate entry and reconstruction of positional information from scanned orthogonal films. MCNP4C Monte Carlo code and TLDs were used for simulation and experimental measurement, respectively. STPS data were also compared with those from a commercial planning system (Nucletron PLATO). Discrepancy values between MCNP and STPS data and also those of PLATO and STPS at Manchester system dose prescription points (AL and AR) of tandem and ovoid configurations were and , respectively. Similar results were achieved for other investigated configurations. Observed discrepancies between MCNP and STPS at the dose prescription point and at 1 cm from the tip of the vaginal applicator were 4.5% and 25.6% respectively, while the discrepancy between the STPS and PLATO data at those points was 2.3%. The software showed submillimeter accuracy in its geometrical reconstructions. In terms of calculation accuracy, similar to PLATO, as attenuation of the sources and applicator body is not considered, dose was overestimated at the tip of the applicator, but based on the available criteria, dose accuracy at most points were acceptable. Our results confirm STPS's geometrical and operational reliability, and show that its dose computation accuracy is comparable to an established commercial TPS using the same algorithm. PACS number: 87.53.Jw
Keywords
This publication has 12 references indexed in Scilit:
- Suitability of point kernel dose calculation techniques in brachytherapy treatment planningJournal of Medical Physics, 2010
- A quantitative three-dimensional dose attenuation analysis around Fletcher-Suit-Delclos due to stainless steel tube for high-dose-rate brachytherapy by Monte Carlo calculationsBrachytherapy, 2009
- A Monte Carlo study of intersource effects in dome-type applicators loaded with LDR Cs-137 sourcesRadiotherapy and Oncology, 2005
- Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicatorRadiotherapy and Oncology, 2005
- The dose distribution of low dose rate Cs-137 in intracavitary brachytherapy: comparison of Monte Carlo simulation, treatment planning calculation and polymer gel measurementPhysics in Medicine & Biology, 2004
- Phantom size in brachytherapy source dosimetric studiesMedical Physics, 2004
- Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effectsMedical Physics, 2004
- On the validity of the superposition principle in dose calculations for intracavitary implants with shielded vaginal colpostatsMedical Physics, 2001
- Shielding effects of Selectron applicator and pellets on isodose distributionsRadiotherapy and Oncology, 1991
- The Effective Attenuation in Water of the Gamma Rays of Gold 198, Iridium 192, Cesium 137, Radium 226, and Cobalt 60Radiology, 1968