Zahra Siavashpour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zahra Siavashpour has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Mahbod Sedaghat
Centre intégré de cancérologie de la Montérégie (CICM), Charles LeMoyne Hospital, Greenfield Park, QC, Canada
2 shared publicationsMahmoud Reza Aghamiri
Department of Medical Radiation Engineering, Shahid Beheshti University, Tehran, Iran
2 shared publicationsRamin Jaberi
Department of Radiotherapy, Tehran University of Medical Sciences, Tehran, Iran
2 shared publicationsChristian Kirisits
Department of Radiotherapy and Oncology Comprehensive Cancer Center, Medical University of Vienna Austria
1 shared publication- Christian Kirisits
Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna, Vienna, Austria
1 shared publication H.A. Nedaie
Department of Radiotherapy, Cancer Institute Tehran University of Medical Sciences Tehran Iran
1 shared publication
Latest Publications
- 1 July 2016
- Published by Elsevier in Brachytherapy
- Vol. 15 (4) , 514-523
Evaluating the utility of “3D Slicer” as a fast and independent tool to assess intrafractional organ dose variations in gynecological brachytherapy
- 1 July 2016
- Published by Elsevier in Brachytherapy
- Vol. 15 (4) , 514-523
Evaluating the utility of “3D Slicer” as a fast and independent tool to assess intrafractional organ dose variations in gynecological brachytherapy
- Open Access
- 8 May 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (3) , 5-13
A comparison of organs at risk doses in GYN intracavitary brachytherapy for different tandem lengths and bladder volumes
The purpose of this study was to investigate the concurrent effects of tandem length and bladder volume on dose to pelvic organs at risk (OARs) in HDR intracavitary brachytherapy treatment of cervical cancer. Twenty patients with locally advanced cervical cancer were selected for brachytherapy using Rotterdam applicators. The patients were CT scanned twice with empty and full bladder. Two treatment plans were prepared on each of the image sets. Patients were categorized into two groups; those treated with a tandem length of 4 cm or smaller and those with tandem length larger than 4 cm ( ). Only one tandem tip angle of 30° was studied. Dose-volume histograms (DVHs) of OARs were calculated and compared. Bladder dose was significantly affected by both bladder volume and tandem physical length for . This was reflected on the values obtained for , , and for both empty and full bladder cases. When , no correlation could be established between variations in bladder dose and bladder volume. Rectum dose was generally lower when the bladder was empty and . Dose to sigmoid was increased when ; this increase was larger when the bladder was full. Our results suggest that, for tandems longer than 4 cm, keeping the bladder empty may reduce the dose to rectum and sigmoid. This is contrary to cases where a shorter than 4 cm tandem is used in which a full bladder (about 50–120 cm3) tends to result in a lower dose to rectum and sigmoid. Attention should be given to doses to sigmoid with long tandem lengths, as a larger tandem generally results in a larger dose to sigmoid. PACS number(s): 87.53.Jw- 8 May 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (3) , 5-13
Open AccessA comparison of organs at risk doses in GYN intracavitary brachytherapy for different tandem lengths and bladder volumes
The purpose of this study was to investigate the concurrent effects of tandem length and bladder volume on dose to pelvic organs at risk (OARs) in HDR intracavitary brachytherapy treatment of cervical cancer. Twenty patients with locally advanced cervical cancer were selected for brachytherapy using Rotterdam applicators. The patients were CT scanned twice with empty and full bladder. Two treatment plans were prepared on each of the image sets. Patients were categorized into two groups; those treated with a tandem length of 4 cm or smaller and those with tandem length larger than 4 cm ( ). Only one tandem tip angle of 30° was studied. Dose-volume histograms (DVHs) of OARs were calculated and compared. Bladder dose was significantly affected by both bladder volume and tandem physical length for . This was reflected on the values obtained for , , and for both empty and full bladder cases. When , no correlation could be established between variations in bladder dose and bladder volume. Rectum dose was generally lower when the bladder was empty and . Dose to sigmoid was increased when ; this increase was larger when the bladder was full. Our results suggest that, for tandems longer than 4 cm, keeping the bladder empty may reduce the dose to rectum and sigmoid. This is contrary to cases where a shorter than 4 cm tandem is used in which a full bladder (about 50–120 cm3) tends to result in a lower dose to rectum and sigmoid. Attention should be given to doses to sigmoid with long tandem lengths, as a larger tandem generally results in a larger dose to sigmoid. PACS number(s): 87.53.Jw - Open Access
- 8 March 2012
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 13 (2) , 103-112
Independent evaluation of an in‐house brachytherapy treatment planning system using simulation, measurement and calculation methods
Accuracy of treatment planning systems may significantly influence the efficacy of brachytherapy. The purpose of this work is a detailed, varied and independent evaluation of an in-house brachytherapy treatment planning software called STPS. Operational accuracy of STPS was investigated. Geometric tests were performed to validate entry and reconstruction of positional information from scanned orthogonal films. MCNP4C Monte Carlo code and TLDs were used for simulation and experimental measurement, respectively. STPS data were also compared with those from a commercial planning system (Nucletron PLATO). Discrepancy values between MCNP and STPS data and also those of PLATO and STPS at Manchester system dose prescription points (AL and AR) of tandem and ovoid configurations were and , respectively. Similar results were achieved for other investigated configurations. Observed discrepancies between MCNP and STPS at the dose prescription point and at 1 cm from the tip of the vaginal applicator were 4.5% and 25.6% respectively, while the discrepancy between the STPS and PLATO data at those points was 2.3%. The software showed submillimeter accuracy in its geometrical reconstructions. In terms of calculation accuracy, similar to PLATO, as attenuation of the sources and applicator body is not considered, dose was overestimated at the tip of the applicator, but based on the available criteria, dose accuracy at most points were acceptable. Our results confirm STPS's geometrical and operational reliability, and show that its dose computation accuracy is comparable to an established commercial TPS using the same algorithm. PACS number: 87.53.Jw- 8 March 2012
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 13 (2) , 103-112
Open AccessIndependent evaluation of an in‐house brachytherapy treatment planning system using simulation, measurement and calculation methods
Accuracy of treatment planning systems may significantly influence the efficacy of brachytherapy. The purpose of this work is a detailed, varied and independent evaluation of an in-house brachytherapy treatment planning software called STPS. Operational accuracy of STPS was investigated. Geometric tests were performed to validate entry and reconstruction of positional information from scanned orthogonal films. MCNP4C Monte Carlo code and TLDs were used for simulation and experimental measurement, respectively. STPS data were also compared with those from a commercial planning system (Nucletron PLATO). Discrepancy values between MCNP and STPS data and also those of PLATO and STPS at Manchester system dose prescription points (AL and AR) of tandem and ovoid configurations were and , respectively. Similar results were achieved for other investigated configurations. Observed discrepancies between MCNP and STPS at the dose prescription point and at 1 cm from the tip of the vaginal applicator were 4.5% and 25.6% respectively, while the discrepancy between the STPS and PLATO data at those points was 2.3%. The software showed submillimeter accuracy in its geometrical reconstructions. In terms of calculation accuracy, similar to PLATO, as attenuation of the sources and applicator body is not considered, dose was overestimated at the tip of the applicator, but based on the available criteria, dose accuracy at most points were acceptable. Our results confirm STPS's geometrical and operational reliability, and show that its dose computation accuracy is comparable to an established commercial TPS using the same algorithm. PACS number: 87.53.Jw