Intra-cranial aneurysm treatment with contour or WEB – a single center comparison of intervention times and learning curves
- 18 June 2023
- journal article
- research article
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 31 (5) , 641-645
Abstract
Background and purpose: Treating aneurysms with intra-saccular flow disruption is a feasible alternative to coil-embolization. Besides the established WEB device, the novel Contour Neurovascular System has emerged as a potentially easier alternative regarding sizing and deployment. We report the learning curve experienced at our center from the first 48 patients treated with Contour and compared it with 48 consecutive WEB cases. Methods: Both groups were compared concerning intervention time, sizing failures leading to device changes and radiation dose. Additionally, we analyzed potential learning effects by comparing the first 24 Contour cases with our last 24 Contour cases and WEB cases respectively. Results: Patient demographics, acute vs. incidental cases and aneurysm localization were comparable in both groups. The deployment time was faster in our 48 Contour cases (median: 22.0 ± 17.0 min), than in the WEB group (median: 27.5 ± 24.0 min). Total intervention time was similar for Contour (median: 68.0 ± 46.9 min) and WEB cases (median: 69.0 ± 38.0 min). Device implantation times in our WEB cases were slightly shorter in the later cases (median: 25.5 ± 24.1 min) than in the earlier (median: 28.0 ± 24.4 min) cases. In the Contour cohort, deployment times were similar for the first 24 cases (median: 22.0 ± 14.5 min) and the final 24 (median: 22.0 ± 19.4 min). Radiation dose was lower in the Contour group (1469.0 ± 1718 mGy*cm 2 vs. 1788.0 ± 1506 mGy*cm 2 using the WEB device). Less intra-procedural device changes were performed in the Contour cohort (6 of 48 cases, 12.5%), than in the WEB group (8 of 48 cases, 16.7%). Conclusion: Aneurysm occlusion times and consequently radiation doses, as well as the amount of device changes were lower in the Contour group. Occlusion times did not differ in the first and last 24 Contour cases, leading to the assumption that the handling of Contour does not require extended training. A short training effect in occlusion times was noted, however, between the first and last WEB cases as shorter procedure times were seen in the latter cases.Keywords
This publication has 10 references indexed in Scilit:
- Endosaccular flow disruption with the Contour Neurovascular System: angiographic and clinical results in a single-center study of 60 unruptured intracranial aneurysmsJournal of NeuroInterventional Surgery, 2022
- A new era in the treatment of wide necked bifurcation aneurysms: Intrasaccular flow disruptionInterventional Neuroradiology, 2022
- The Safety and Effectiveness of the Contour Neurovascular System (Contour) for the Treatment of Bifurcation Aneurysms: The CERUS StudyNeurosurgery, 2021
- CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS): results of 1-month and 1-year assessment of rebleeding protection and clinical safety in a multicenter studyJournal of NeuroInterventional Surgery, 2021
- Radiation dose and fluoroscopy time of modern endovascular treatment techniques in patients with saccular unruptured intracranial aneurysmsEuropean Radiology, 2020
- Endovascular treatment of wide-necked intracranial aneurysms using the novel Contour Neurovascular System: a single-center safety and feasibility studyJournal of NeuroInterventional Surgery, 2020
- Safety and Efficacy of Aneurysm Treatment with the WEB: Results of the WEBCAST 2 StudyAmerican Journal of Neuroradiology, 2017
- Demographic, procedural and 30-day safety results from the WEB Intra-saccular Therapy Study (WEB-IT)Journal of NeuroInterventional Surgery, 2017
- Clinical and Anatomical Follow-up in Patients With Aneurysms Treated With the WEB DeviceNeurosurgery, 2016
- Intrasaccular Flow Disruption in Acutely Ruptured Aneurysms: A Multicenter Retrospective Review of the Use of the WEBAmerican Journal of Neuroradiology, 2015