FGFriederike Gärtner

Friederike Gärtner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Friederike Gärtner has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Morphological factors and device deformation associated with recurrence in intracranial aneurysms treated with the contour neurovascular system

    by Naomi Larsen, Fritz Wodarg, Johannes Hensler, Karim Mostafa, Sönke Peters, Mariya Pravdivtseva, Sylvia Saalfeld, Friederike Gärtner


  • DWI lesions after intracranial aneurysm treatment with contour or WEB—does the device matter?

    by Friederike Gärtner, Tristan Klintz, Sönke Peters, Justus Mahnke, Karim Mostafa, Fernando Bueno Neves, Johannes Hensler, Naomi Larsen, Olav Jansen, Fritz Wodarg

    Objective: In this study, we report our experience with the occurrence of diffusion-weighted imaging (DWI) lesions following aneurysm treatment with Woven EndoBridge (WEB) device and Contour Neurovascular System in elective settings. We compared both techniques in a retrospective single-center analysis, to investigate whether there are significant differences in the incidence of microemboli depending on the device used. Materials and methods: Sixty-two cases treated with Contour were retrospectively compared with 84 WEB cases. Postinterventional MRI was performed in all patients within five days after the angiographic procedure. Only DWI lesions in the dependent vascular territory of the treated aneurysm were considered. Data on occurrence of DWI lesions, device implantation times as well as device change or repositions maneuvers were compared. Results: A total of 146 patients were included in this study. Postinterventional DWI lesions were detected in 33 of the 62 (53.2%) Contour cases and in 36 of the 84 (42.8%) WEB cases with an average lesion number of 1.70 ± 3.45 in our WEB group and 1.68 ± 2.53 in our Contour cohort. Neither periinterventional device changes nor device reposition maneuvers had a significant impact on the occurrence of DWI lesions. Although four patients experienced transient neurological deterioration, the DWI lesions were not clinically relevant at the time of discharge, as the patients’ NIHSS remained stable compared to the preintervention NIHSS in the entire cohort. There was no statistically significant difference between the implantation times of WEB and Contour, although Contour could be implanted slightly faster. Conclusion: Aneurysm treatment with WEB or Contour results in a comparable numbers of procedure-related DWI lesions. This effect was consistent after adjustment for other demographic or technical variables.


  • Contour device implantation for treatment of intracranial aneurysms in the basilar tip

    by Karim Mostafa, Fernando Bueno Neves, Friederike Gärtner, Sönke Peters, Johannes Hensler, Naomi Larsen, Tristan Klintz, Justus Mahnke, Charlotte Flüh, Olav Jansen, et al.

    Introduction: Treatment of basilar apex aneurysms will remain challenging regarding the nobility of the parent vessel and their often wide-necked configuration. With endovascular techniques being the treatment approach of choice, novel intrasaccular flow-disruption devices constitute an endovascular embolization option. In this research, we report our experiences in embolizing basilar tip aneurysms with the novel Contour device. Material and methods: Retrospective analysis of eight patients after Contour implantation into a basilar apex aneurysm. Periprocedural data on intervention times, radiation dose, procedural success and complications were gathered. All patients received follow-up digital subtraction angiography after six months. Further follow-up examination results were analysed given their availability. Results: Contour implantation was successful in all patients. The mean device instrumentation time was 18.8 ± 7.7 min with a mean full intervention time of 100 ± 65.8 min. The mean full procedure radiation dose was 1917 (421–5107) cGy/cm 2 . After six months, six aneurysms were occluded (Raymond Roy Scale (RRS) 1/2), one showed perfusion inside the device (RRS 3a) and one patient had undergone reintervention due to progression. The aneurysm with constant perfusion at six months was seen to be occluded after 24 months. Conclusion: Contour device implantation is a promising feasible alternative endovascular method for embolization of intracranial aneurysms located in the basilar tip with short intervention times and low radiation dosages. Short- and medium-term follow-ups show promising results concerning aneurysm occlusion and reinterventions, however further research is needed to show long-term stability.


  • Intra-cranial aneurysm treatment with contour or WEB – a single center comparison of intervention times and learning curves

    by Friederike Gärtner, Tristan Klintz, Sönke Peters, Fernando Bueno Neves, Karim Mostafa, Justus Mahnke, Johannes Hensler, Charlotte Flüh, Naomi Larsen, Olav Jansen, et al.

    Background and purpose: Treating aneurysms with intra-saccular flow disruption is a feasible alternative to coil-embolization. Besides the established WEB device, the novel Contour Neurovascular System has emerged as a potentially easier alternative regarding sizing and deployment. We report the learning curve experienced at our center from the first 48 patients treated with Contour and compared it with 48 consecutive WEB cases. Methods: Both groups were compared concerning intervention time, sizing failures leading to device changes and radiation dose. Additionally, we analyzed potential learning effects by comparing the first 24 Contour cases with our last 24 Contour cases and WEB cases respectively. Results: Patient demographics, acute vs. incidental cases and aneurysm localization were comparable in both groups. The deployment time was faster in our 48 Contour cases (median: 22.0 ± 17.0 min), than in the WEB group (median: 27.5 ± 24.0 min). Total intervention time was similar for Contour (median: 68.0 ± 46.9 min) and WEB cases (median: 69.0 ± 38.0 min). Device implantation times in our WEB cases were slightly shorter in the later cases (median: 25.5 ± 24.1 min) than in the earlier (median: 28.0 ± 24.4 min) cases. In the Contour cohort, deployment times were similar for the first 24 cases (median: 22.0 ± 14.5 min) and the final 24 (median: 22.0 ± 19.4 min). Radiation dose was lower in the Contour group (1469.0 ± 1718 mGy*cm 2 vs. 1788.0 ± 1506 mGy*cm 2 using the WEB device). Less intra-procedural device changes were performed in the Contour cohort (6 of 48 cases, 12.5%), than in the WEB group (8 of 48 cases, 16.7%). Conclusion: Aneurysm occlusion times and consequently radiation doses, as well as the amount of device changes were lower in the Contour group. Occlusion times did not differ in the first and last 24 Contour cases, leading to the assumption that the handling of Contour does not require extended training. A short training effect in occlusion times was noted, however, between the first and last WEB cases as shorter procedure times were seen in the latter cases.


  • Open Access

    CT and MRI Findings in Cerebral Aspergilloma

    by Friederike Gärtner, Julia Forstenpointner, Birgit Ertl-Wagner, Babak Hooshmand, Christian Riedel, Olav Jansen

    Purpose Invasive aspergillosis usually affects immunocompromised patients. It carries a high risk of morbidity and mortality and usually has a nonspecific clinical presentation. Early diagnosis is essential in order to start effective treatment and improve clinical outcome. Materials and Methods In a retrospective search of the PACS databases from two medical centers, we identified 9 patients with histologically proven cerebral aspergilloma. We systematically analyzed CT and MRI imaging findings to identify typical imaging appearances of cerebral aspergilloma. Results CT did not show a typical appearance of the aspergillomas. In 100 % (9/9) there was a rim-attenuated diffusion restriction on MRI imaging. Multiple hypointense layers in the aspergillus wall, especially on the internal side, were detected in 100 % on T2-weighted imaging (9/9). Aspergillomas were T1-hypointense in 66 % of cases (6/9) and partly T1-hyperintense in 33 % (3/9). In 78 % (7/9) of cases, a rim-attenuated diffusion restriction was detected after contrast agent application. Conclusion Nine cases were identified. Whereas CT features were less typical, we observed the following imaging features on MRI: A strong, rim-attenuated diffusion restriction (9/9); onion layer-like hypointense zones, in particular in the innermost part of the abscess wall on T2-weighted images (9/9). Enhancement of the lesion border was present in the majority of the cases (7/9). Key points Citation Format