Abstract
INTRODUCTION: Periprosthetic joint infection (PJI) of the hip is one of the leading causes of revision hip arthroplasty. An analysis of current treatment practices has shown increasing PJI recurrence rates, along with a rise in Gram-negative infections in the PJI etiology. Our study examined the clinical course of acute infection caused by Staphylococcus aureus / Klebsiella pneumoniae in a patient treated with a prototype acetabular component with a zinc-containing calcium phosphate coating applied by microarc oxidation, used as a spacer. CASE DESCRIPTION: We present a clinical case of a patient with chronic deep periprosthetic infection (recurrence) after total hip arthroplasty of the right hip. A custom implant with a zinc-containing calcium phosphate coating was used. Surgical treatment included removal of the right hip prosthesis, debridement of the surgical site, implantation of the custom implant, and placement of an Osteomed femoral component as a spacer. On postoperative day 21, a fistula appeared and was considered a PJI recurrence. On day 22, a repeat procedure was performed: total removal of the articulating spacer (custom acetabular component with Zn-containing coating), intraoperative sampling of tissue surrounding the acetabular and femoral components, and placement of a block spacer. In material from the implant screw holes and surrounding tissues, we found areas of subtotal necrosis of loose connective tissue interspersed with dense, diffuse inflammatory infiltrate of polynuclear leukocytes. Elemental analysis showed no zinc ions in the tissues surrounding the implant. CONCLUSION: The implant with zinc-containing calcium phosphate coating did not exhibit bactericidal activity in acute PJI, as there was no diffusion of zinc ions into the surrounding tissues, or diffusion was too weak to provide sufficient zinc locally.Keywords
This publication has 22 references indexed in Scilit:
- Challenges and strategies in the treatment of periprosthetic joint infection caused by multidrug-resistant Gram-negative bacteria: a narrative reviewClinical Microbiology and Infection, 2025
- Zinc-Doped Antibacterial Coating as a Single Approach to Unlock Multifunctional and Highly Resistant Titanium Implant SurfacesACS Applied Materials & Interfaces, 2025
- How long do revised and multiply revised hip replacements last? A retrospective observational study of the National Joint RegistryThe Lancet Rheumatology, 2022
- Diatomite-based ceramic biocoating for magnesium implantsCeramics International, 2022
- Additively manufactured porous titanium 3D–scaffolds with antibacterial Zn-, Ag- calcium phosphate biocoatingsMaterials Characterization, 2022
- Zn-, Cu- or Ag-incorporated micro-arc coatings on titanium alloys: Properties and behavior in synthetic biological mediaSurface and Coatings Technology, 2019
- At the Nexus of Antibiotics and Metals: The Impact of Cu and Zn on Antibiotic Activity and ResistanceTrends in Microbiology, 2017
- Periprosthetic joint infectionThe Lancet, 2016
- The efficacy of zinc supplementation in young children with acute lower respiratory infections: A randomized double-blind controlled trialClinical Nutrition, 2013
- Prosthetic Joint Infection Risk after TKA in the Medicare PopulationClinical Orthopaedics and Related Research, 2010