EAEvgeniya A. Anastasieva

Evgeniya A. Anastasieva

*This is an algorithmically generated author record based on publicly available information.

Evgeniya A. Anastasieva has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    First clinical experience with a custom-made acetabular implant featuring a zinc-containing biocoating for the treatment of deep periprosthetic surgical site infections

    by Irina А. Kirilova, Кирилова Ирина Анатольевна, Peter M. Larionov, Ларионов Петр Михайлович, Maxim V. Efimenko, Ефименко Максим Владимирович, Evgeniya A. Anastasieva, Анастасиева Евгения Андреевна, Vyacheslav A. Bazlov, Базлов Вячеслав Александрович, et al.

    INTRODUCTION: Periprosthetic joint infection (PJI) of the hip is one of the leading causes of revision hip arthroplasty. An analysis of current treatment practices has shown increasing PJI recurrence rates, along with a rise in Gram-negative infections in the PJI etiology. Our study examined the clinical course of acute infection caused by Staphylococcus aureus / Klebsiella pneumoniae in a patient treated with a prototype acetabular component with a zinc-containing calcium phosphate coating applied by microarc oxidation, used as a spacer. CASE DESCRIPTION: We present a clinical case of a patient with chronic deep periprosthetic infection (recurrence) after total hip arthroplasty of the right hip. A custom implant with a zinc-containing calcium phosphate coating was used. Surgical treatment included removal of the right hip prosthesis, debridement of the surgical site, implantation of the custom implant, and placement of an Osteomed femoral component as a spacer. On postoperative day 21, a fistula appeared and was considered a PJI recurrence. On day 22, a repeat procedure was performed: total removal of the articulating spacer (custom acetabular component with Zn-containing coating), intraoperative sampling of tissue surrounding the acetabular and femoral components, and placement of a block spacer. In material from the implant screw holes and surrounding tissues, we found areas of subtotal necrosis of loose connective tissue interspersed with dense, diffuse inflammatory infiltrate of polynuclear leukocytes. Elemental analysis showed no zinc ions in the tissues surrounding the implant. CONCLUSION: The implant with zinc-containing calcium phosphate coating did not exhibit bactericidal activity in acute PJI, as there was no diffusion of zinc ions into the surrounding tissues, or diffusion was too weak to provide sufficient zinc locally.

  • Open Access

    Role of olecranon osteosynthesis types and approaches in surgical treatment of patients with distal humerus fractures: a systematic review

    by T. E. Prokopovich, A. E. Medvedchikov, E. A. Anastasieva, I. A. Kirilova

    Introduction Distal humerus fractures account for about 2 % of all fractures, with annual fracture incidence up to 5.7–8.3 cases per 100,000 population. In this regard, optimal surgical treatment methods continue to be sought. Despite the widespread use of olecranon osteotomy to approach the humerus, the choice of an osteotomy type and fixator for an artificial fracture consolidation remains with the surgeon. This paper systematizes the available literature related to types of osteotomies, types of fixators, and characteristics of complications. Purpose To evaluate the results of performing olecranon osteotomy to approach the humeral trochlea in the treatment of distal humerus fractures, to determine the optimal type of approach, type of osteotomy and type of fixators for an artificial olecranon fracture in the surgical treatment of distal humerus fractures. Material and methods The search for publications was carried out in the PubMed, Google Scholar, eLibrary databases for the period from 2020 to 2025. Studies that described olecranon osteotomy in the surgical treatment of distal humerus fractures (DHFs) were selected. After evaluating 595 articles, 18 studies with a total sample size of 640 patients were included in the systematic review according to the PRISMA criteria. Results and discussion The results of the review are: the overall incidence of delayed consolidation was 5 out of 112 cases (4.46 %), pseudarthrosis developed in 24 out of 416 (5.76 %), and metal implant broke in 10 out of 150 (6.6 %). Development of surgical site infection in the early postoperative period was described in 37 out of 473 (7.82 %). Metal implants were removed in the postoperative period in 55 out of 297 cases (18.51 %). The incidence was calculated based on the available data for each described complication. Conclusion The results of olecranon osteotomy used to approach to the humeral trochlea in distal humerus fracture treatment have been evaluated. Based on the results of this systematic review, it is impossible to indicate the optimal approach, type of osteotomy and type of fixation due to the limited data. However, given the available statistics, it is possible to assume the advantage of the Tension Band Wiring (TBW) method. Therefore, the issue of conducting experimental and prospective studies remains open.

  • Open Access

    Minimally manipulated adipose tissue and bone marrow cellular products for bone tissue regeneration: what to choose? A systematic review

    by E. A. Anastasieva, L. A. Cherdantseva, T. E. Prokopovich, A. E. Medvedchikov, I. A. Kirilova

    According to numerous data presented in the scientific sources, the use of minimally manipulated cellular products with their own mesenchymal stem cells (MSCs) improves the results of surgical treatment of bone injuries. However, there is currently no consensus on the preferred use of MSCs from bone marrow or from adipose tissue. This is due to the accumulation of positive experience of their use in the restoration of bone defect. The purpose of the work. Determination of the optimal source of mesenchymal stem cells for surgical reconstruction of a bone defect. Material and methods. The search for publications for the period 2021–2025 was carried out in the databases PubMed, eLIBRARY.RU, Google Scholar and other scientific sources. The selected studies contained data on the use of MSCs from bone marrow and adipose tissue, as well as on the technique of their use. According to the PRISMA criteria, 16 publications were screened, of which 10 did not contain the necessary data on the concentration of cellular components and the technique of their application. Thus, a quantitative analysis of the data from 6 publications was carried out. Results and discussion. Currently, the technique of obtaining and preparing minimally manipulated cellular products with bone marrow MSCs for surgical treatment in traumatology and orthopedics is technically simpler and requires less time than the technique with adipose tissue MSCs. This may be one of the reasons for the prevalence of publications describing the use of bone marrow MSCs in clinical practice. The use of mesenchymal stem cells in the area of surgical reconstruction of a bone defect is necessary, however, there is no consensus on the best source of MSCs. Conclusions. According to the conducted analysis of literary sources, the technique using bone marrow MSCs has an advantage due to the reduction of the duration of the operation, however, the effectiveness of the cellular fraction of the bone marrow aspirate can be significantly reduced by errors in the collection technique and the composition of the aspirate itself. Techniques using adipose tissue MSCs have fewer errors, but a longer intervention time. At the same time, reliably important factors for increasing the effectiveness of bone defects surgical treatment with using minimally manipulated cellular products with MSCs are: heterogeneity and a sufficient amount of cellular fraction (no more than 1 million cells), as well as the presence of a carrier matrix.

  • Open Access

    Morphological Assessment of Osseointegration of Titanium Implants with Ag- and Zn-Containing Calcium Phosphate Coatings

    by Igor V. Maiborodin, Vitalina I. Maiborodina, Boris V. Sheplev, Yuri i P. Sharkeev, Mariya B. Sedelnikova, Vitaliy V. Pavlov, Vyacheslav A. Bazlov, Evgeniya A. Anastasieva, Maxim V. Efimenko, Irina А. Kirilova Irina А. Kirilova, et al.

    Background. The condition of the implant surface plays an important role in extending the service life of implants and metal structures in the human body. The aim of the study — to assess the effect of titanium implants with Ag- or Zn-containing calcium phosphate coatings on the surrounding bone tissue in experimental study. Methods. Using light microscopy, we studied the condition of bone tissue in the proximal tibia (PT) of rabbits 4 weeks after the implantation of 3D-printed titanium cone-shaped implants with Ag- or Zn-containing calcium phosphate coating. Results. In all cases, 3D-printed titanium implants with a rough surface integrated in the PT adhered very tightly to the bone tissue, the edges of which had minor cicatricial changes. Removal of the implants was difficult, and many tissue fragments remained on their surface. Small foreign fragments were present in the bone tissue samples examined. The sizes of foreign fragments were smaller after the use of silver ions, compared to the use of zinc ions, in both compact and cancellous bone by 84.4% (9.50±4.17 vs 17.78±7.95 μm) and 87.2% (11.21±10.68 vs 20.67±8.08 μm), respectively. In cancellous bone, the average diameter of the fragment groups and the average distance between the coating fragments or their groups were not statistically significantly different. In compact bone, they were 59.1% (155±35.98 vs 246.67±39.62 μm) and 21.2% (253.04±44.87 vs 308±50.85 μm) larger, respectively, after application of the Zn-containing coating. Conclusions. Surface-modified titanium implants have demonstrated a tendency to osseointegration, even when the coating is damaged with the formation of foreign fragments migrating into the surrounding tissues. It is possible that modifying the technique and modes of coating application, as well as varying their thickness, will enable the full realization of the positive properties of the modified surface, including the beneficial antimicrobial characteristics of silver and zinc.


  • Open Access

    Effective combination of arthroscopic and minimally invasive surgery for chronic posterolateral elbow instability

    by A. E. Medvedchikov, E. A. Anastasieva, B. A. Oleynik, A. A. Simonyan, T. E. Prokopovich, I. A. Kyrilova

    Introduction Trauma and extreme physical activity may result in common patterns of forearm dislocation, which account for 10 to 25 % of all elbow injuries in the adult population. Good long-term results of eliminating joint dislocation with the use of conservative treatment have been much described, but 8 % of patients experience symptoms of chronic instability. We present a case of successful arthroscopic treatment of ligamentous stabilizers of the elbow joint using an effective combination of implants for its posterolateral instability. We found no publications on such an experience in the Russian literature.The purpose of the work is to present a clinical case of an effective combination of arthroscopic and minimally invasive surgery methods for reconstruction of the ligamentous apparatus in chronic posterolateral instability of the elbow joint.Material and methods Patient N., 31 years old, suffered chronic posterolateral rotational instability of the left elbow joint after dislocation of the forearm bones for more than 10 years. The operative technique was based on the principles of minimally invasive reconstructive plastic surgery and meets the objectives of gentle treatment of soft tissues, allowing visualization of the lesion and avoiding the contact with neuro‑vascular structures. Baseline clinical tests (O'Driscoll, Regan/Lapner, Pollock), questionnaires (VAS, DASH, MEPS, SF‑36), and MRI, 1.5 Tesla MRI scans of dynamic stabilizer disruption are reflected. Evaluation was performed at two control points (45 and 180 days).Results The assessment was carried out at two control points. First follow-up (45 days): flexion/extension 50/175º, pronation/supination 90/90º, VAS 2, DASH 24.2, MEPS 80 points, respectively. Second follow‑up (180 days): VAS 1, DASH 9.2, MEPS 95 points, comparative ranges of motion corresponded to a healthy joint. An MRI study confirmed the progress of the autotenograft and tendon ligamentization in the area of reinsertion, the absence of inflammatory changes and no heterotopic ossification.Discussion Improvements in elbow surgery and technical progress are focused on minimally invasive interventions, while arthroscopy of the elbow joint is still technically difficult due to a limited space. And yet, this is an effective treatment method, as a result of which specialists can avoid a wide range of complications (14.7 %), and patients start rehabilitation faster and, as a result, recover faster than with open surgical approaches with a higher percentage of risks (52 %).Conclusion The combination of the above techniques avoids conflict with neurovascular structures, provides visual control of the implantation of anchors and, as a result, reduces the overall risk of complications in the treatment of a rare group of patients with instability of the elbow joint.

  • Open Access

    Bone defect management with tissue-engineered constructs based on deproteinized cancellous bone: an experimental study

    by E. A. Anastasieva, L. A. Cherdantseva, T. G. Tolstikova, I. A. Kirilova

    Background Management of bone defects with autologous bone grafting has always been the "gold standard" but it is not always possible to use it for a number of reasons. Preprocessed materials of biological and non-biological origin were developed as an alternative. A new branch of these materials is tissue-engineered constructs that fully imitate autologous bone in required volume.Aim is to study in vivo the possibility of using deproteinized human cancellous bone tissue as a matrix for creating tissue-engineered constructs.Methods The study was carried out on 24 NZW line rabbits, since this line has a fully characterized stromal-vascular fraction formula (SVF). The study design included 3 groups. First group (control) had surgical modeling of bone defects in the diaphysis of the contralateral femur without reconstruction; Group 2 had bone defect reconstruction using fragments of a deproteinized cancellous bone graft; group 3 underwent bone defect reconstruction using fragments of deproteinized cancellous bone matrix along with the autologous adipose tissue SVF (obtained according to ACP SVF technology). Animals were sacrificed with ether anesthesia at 2, 4 and 6 weeks after the operation and subsequent histological study followed.Result During all periods of the study, the newly formed bone tissue volume density in the 3rd group (reconstruction with deproteinized human cancellous bone + stromal-vascular fraction) was 1.78 times higher (p < 0.001) than in the first group (bone defect without reconstruction), 1.21 times higher (p < 0.001) than in the 2nd group (reconstruction with deproteinized cancellous bone alone). The dynamics of changes in the mature bone tissue volume density was similar to those of the newly formed bone tissue.Discussion The comparative analysis of reparative processes using a tissue engeneered construst based on deproteinized cancellous human bone with adipose tissue stromal vascular fraction revealed that the use of these bone substitute materials contributes not only to the early activation of reparative regeneration of the main structural elements of bone tissue at the site of bone defect, but also their timely differentiation.Conclusion The use of deproteinized cancellous bone matrix combined with stromal-vascular fraction to create a tissue-engineered construct could unleash several regeneration mechanisms and accelerate the process of bone defect site repair, compared with 1st and 2nd group of study.


  • Open Access

    Restoration of X-ray bone density when replacing cortical plate defects with a tissue-engineered construct in the experiment

    by E. A. Anastasieva, L. A. Cherdantseva, A. E. Medvedchikov, V. L. Lukinov, I. A. Kirilova

    Over the past decade, in global practice, the frequency of using high-resolution multi-layer spiral computed tomography (MSCT) for assessing the state of cancellous and cortical bone tissue has significantly increased. Using high-resolution MSCT makes it possible to assess X-ray bone density at various times after replacement of cortical plate defects with osteoplastic materials. The aim of the research. To study the restoration of cortical bone density in the area of osteoplasty using tissue-engineered construct in the experiment. Materials and methods. In an in vivo experiment on New Zeland White (NZW) rabbits, perforation defects of cortical bone were formed in the femoral diaphysis. Three study groups were set up: group 1 – without bone defect replacement; group 2 – with bone defect replacement with deproteinized cancellous bone; group 3 – with bone defect replacement with tissue-engineered construct based on deproteinized cancellous bone with stromal vascular fraction of adipose tissue. Follow-up periods were 2, 4 and 6 weeks after the surgery. The X-ray density of cortical bone tissue was measured in Hounsfield units (HU). Fragments of deproteinized human cancellous bone were used alone and in combination with the stromal vascular fraction of NZW rabbit adipose tissue as a bone-replacing material for bone defect replacement. Results. Cortical plate density the in the area of the defect in the group 3 by the week 6 is on average 1.3 times lower than that of the intact cortical plate and corresponds to D1 according to Misch classification. Cortical plate density in the area of the defect on the side of medullary canal by the week 6 in the group 3 corresponds to D1 according to Misch classification and is equal to 1351.25 ± 221.18 HU (1052; 1805), which is 1.5 times higher than in group 2 (D2 according to Misch classification; p < 0.05). The obtained results indicate an earlier restoration of X-ray bone density when using a tissue-engineered construct (group 3) compared to the same indicators in groups 1 and 2.


  • Open Access

    Clinical case of the surgical treatment of complete rupture of distal biceps tendon using two cortical buttons

    by A. E. Medvedchikov, E. A. Anastasieva, V. M. Prokhorenko, I. A. Kirilova

    Distal biceps tendon injuries mainly occur in men from the active groups of population. Among the athletes and military personnel, the incidence rate is 2–10 % of the upper limb tendon injuries. Comparative studies have shown the achievement of better functional results in surgical treatment, while maintaining overall complication rate of 4.6–25 %. The aim. To demonstrate a new reinsertion technique with two cortical buttons in case of complete rupture of distal biceps tendon as part of a clinical case. Materials and methods. The article presents a clinical case of surgical treatment of a patient with complete rupture of dominant limb distal biceps tendon which was more than 2 weeks old and was accompanied by lacertus fibrosus provocation and persistent muscle retraction. Results. We obtained the following clinical results by the week 24 after the surgery: VAS (Visual Analogue Scale) score – 1 cm, ASES (American Shoulder and Elbow Surgeons) score – 99 points, DASH (Disabilities of the Arm, Shoulder and Hand) score – 15 points. Dynamometry results: Dex. 85; sin. 90 (2daN); range of motion corresponds to the same of a healthy joint. MRI at 1.5 T shows no signs of synostosis or heterotopic ossification; MSCT shows no signs of migration of cortical buttons in comparison with intraoperative X-ray control. Discussion. Extracortical methods of distal biceps tendon positioning in anatomical reinsertion have lower strength indicators, comparable with the use of transosseous sutures and anchor fixators. A larger area of contact of the studied zone in case of minimal tendon compression in the area of proximal radioulnar space or inside the formed radial bone canal provides high strength indicators and reduces the risk of repeated injury. Conclusion. The scores of the scales (VAS, DASH, ASES) turned out to be better than when using other common methods. The technique of dipping distal biceps tendon stump into the formed oval canal of the “anatomical impression” using the proposed method meets the objectives of careful attitude to the tendon and provides the largest area of its contact with the bone.


  • Open Access

    Deproteinized Bone Tissue as a Matrix for Tissue-Engineered Construction: Experimental Study

    by Evgeniya A. Anastasieva, Liliya A. Cherdantseva, Tatyana G. Tolstikova, Irina A. Kirilova, Черданцева Лилия Александровна

    Background. At present, for a number of reasons the complete bone defect replacement with autogenous bone is not always possible. Bone substitute materials are used as an alternative to autogenous bone tissue and can be of either biological or non-biological origin. One of the ways of development of reconstructive technologies is the use of tissue-engineered constructs that fully imitate autogenous bone tissue in the required volume. Aim of study to define in vivo the possibility of using deproteinized human cancellous bone tissue as a matrix for creating tissue-engineered constructs. Methods. An in vivo study was carried out on NZW rabbits. To create a construct, we used the fragments of deproteinized cancellous bone tissue of the human femoral head and stromal vascular fraction of rabbit adipose tissue as a matrix. Bone defect modeling with its subsequent replacement was performed to evaluate the efficacy of reparative osteogenesis during bone defects reconstruction. Study groups were defined: group 1 (control) surgical modeling of a bone defect of the femur without its reconstruction; group 2 surgical modeling of a bone defect of the femur with its reconstruction using fragments of deproteinized cancellous bone matrix; group 3 surgical modeling of a bone defect of the femur with its reconstruction using fragments of deproteinized cancellous bone matrix in combination with stromal vascular fraction of adipose tissue (according to ACP SVF technology). Results. Comparative analysis of reparative processes in case of applying tissue-engineered constructs based on deproteinized human cancellous bone matrix in combination with adipose tissue-derived stromal vascular fraction on in vivo experimental model revealed that the use of these bone substitute materials contributes not only to an early activation of reparative regeneration of main structural elements of the bone tissue in the area of the bone defect replacement, but also to its well-timed differentiation. This determines the restoration of structural and functional viability of the bone tissue at the damage site without developing discernible reactive inflammation. Moreover, the effect of the selected tissue-engineered construct with the combined influence of several factors (ACP SVF) in its composition turned out to be more effective in stimulating bone tissue repair and differentiation. Conclusion. Combination of SVF and deproteinized bone matrix for creating tissue-engineered constructs enables to engage several regeneration mechanisms and accelerate the process of bone defect replacement in comparison with isolated deproteinized bone matrix without bone defect reconstruction.


  • The impact of structural characteristics of deproteinized spongy bone on the activity of mesenchymal stromal cells of adipose tissue

    by L. A. Cherdantseva, E. A. Anastasieva, M. N. Egorikhina, D. Ya. Aleynik, A. E. Medvedchikov, Yu. P. Sharkeev, I. A. Kirilova