Stress distribution in cylindrical and conical implants under rotational micromovement with different boundary conditions and bone properties: 3-D FEA
- 23 March 2017
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (8) , 893-900
Abstract
Factors related to micromovements at bone-implant interface have been studied because they are considered adverse to osseointegration. Simplifications are commonly observed in these FEA evaluations. The aim of this study was to clarify the influence of FEA parameters (boundary conditions and bone properties) on the stress distribution in peri-implant bone tissue when micromovements are simulated in implants with different geometries. Three-dimensional models of an anterior section of the jaw with cylindrical or conical titanium implants (4.1 mm in width and 11 mm in length) were created. Micromovement (50, 150, or 250 μm) was applied to the implant. The FEA parameters studied were linear vs. non-linear analyses, isotropic vs. orthogonal anisotropic bone, friction coefficient (0.3) vs. frictionless bone-implant contact. Data from von Mises, shear, maximum, and minimum principal stresses in the peri-implant bone tissue were compared. Linear analyses presented a relevant increase of the stress values, regardless of the bone properties. Frictionless contact reduced the stress values in non-linear analysis. Isotropic bone presented lower stress than orthogonal anisotropic. Conical implants behave better, in regard to compressive stresses (minimum principal), than cylindrical ones, except for nonlinear analyses when micromovement of 150 and 250 μm were simulated. The stress values raised as the micromovement amplitude increased. Non-linear analysis, presence of frictional contact and orthogonal anisotropic bone, evaluated through maximum and minimum principal stress should be used as FEA parameters for implant-micromovement studies.Keywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2012/19374-5, 2013/08031-2)
This publication has 14 references indexed in Scilit:
- Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an in vitro InvestigationClinical Oral Implants Research, 2016
- Does Implant Design Affect Implant Primary Stability? A Resonance Frequency Analysis–Based Randomized Split-Mouth Clinical TrialJournal of Oral Implantology, 2015
- Analysis of the influence of implant shape on primary stability using the correlation of multiple methodsClinical Oral Investigations, 2015
- Effects of the Implant Design on Peri‐Implant Bone Stress and Abutment Micromovement: Three‐Dimensional Finite Element Analysis of Original Computer‐Aided Design ModelsJournal of Periodontology, 2014
- Influence of Different Soft Liners on Stress Distribution in Peri-Implant Bone Tissue During Healing Period. A 3D Finite Element AnalysisJournal of Oral Implantology, 2013
- Evaluation of Optimal Taper of Immediately Loaded Wide-Diameter Implants: A Finite Element AnalysisJournal of Oral Implantology, 2013
- Effect of Model Parameters on Finite Element Analysis of Micromotions in Implant DentistryJournal of Oral Implantology, 2013
- From brittle to ductile fracture of boneNature Materials, 2005
- De novo alveolar bone formation adjacent to endosseous implantsClinical Oral Implants Research, 2003
- Two‐Stage Versus One‐Stage—Is There Really a Controversy?Journal of Periodontology, 2001