An impedance-based flow microcytometer for single cell morphology discrimination
- 30 May 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (14) , 2548-2555
Abstract
Cell shape is a fundamental biological feature, providing specific information about physiological or pathological cellular conditions. Most of the state-of-the-art microfluidic cytometers, however, only allow simple cell analysis, including viability studies, cell counting and sorting. In this work, we present a non-invasive, label-free device capable of single cell morphology discrimination in continuous flow. The device is based on the principle of liquid electrodes, fabricated in a cross configuration around a sensing zone. This arrangement allows measurement of cell impedance along orthogonal orientations and extraction of an index describing cell shape anisotropy. By adding prior to the sensing volume a series of lateral liquid electrodes, the particle stream was focused toward the channel midline and each cell was oriented in a specific direction before shape sensing. We demonstrate the proof of concept by performing spherical and elongated particle discrimination. As an application, we show that the shape changes experienced during cell division can be monitored and characterized. In particular, budding yeasts at different stages of the mitotic cycle were identified by extracting their anisotropy index.Keywords
This publication has 20 references indexed in Scilit:
- Tracking and synchronization of the yeast cell cycle using dielectrophoretic opacityLab on a Chip, 2011
- Sickle-cell diseaseThe Lancet, 2010
- Microfluidic impedance‐based flow cytometryCytometry Part A, 2010
- Single Cell Impedance Cytometry for Identification and Counting of CD4 T-Cells in Human Blood Using Impedance LabelsAnalytical Chemistry, 2010
- Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometryLab on a Chip, 2009
- Dielectrophoretic sorting on a microfabricated flow cytometer: Label free separation of Babesia bovis infected erythrocytesBioelectrochemistry, 2008
- Characterization and optimization of liquid electrodes for lateral dielectrophoresisLab on a Chip, 2006
- Invasion of Red Blood Cells by Malaria ParasitesCell, 2006
- Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerationsLab on a Chip, 2004
- Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizingLab on a Chip, 2001