Deriving motion from megavoltage localization cone beam computed tomography scans
- 12 June 2009
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (13) , 4195-4212
Abstract
Cone beam computed tomography (CBCT) projection data consist of views of a moving point (e.g. diaphragm apex). The point is selected in identification views of extreme motion (two inhale, two exhale). The room coordinates of the extreme points are determined by source-to-view ray tracing intersections. Projected to other views, these points become opposite corners of a motion-bounding box. The view coordinates of the point, relative to the box, are used to interpolate between extreme room coordinates. Along with the views' time stamps, this provides the point's room coordinates as a function of time. CBCT-derived trajectories of a tungsten pin, moving 3 cm cranio-caudally and 1 cm elsewhere, deviate from expected ones by at most 1.06 mm. When deviations from the ideal imaging geometry are considered, mean errors are less than 0.2 mm. While CBCT-derived cranio-caudal positions are insensitive to the choice of identification views, the bounding box determination requires view separations between 15 and 163 degrees . Inhale views with the two largest amplitudes should be used, though corrections can account for different amplitudes. The information could be used to calibrate motion surrogates, adaptively define phase triggers immediately before gated radiotherapy and provide phase and amplitude sorting for 4D CBCT.Keywords
This publication has 21 references indexed in Scilit:
- Low dose megavoltage cone beam computed tomography with an unflattened 4 MV beam from a carbon targetMedical Physics, 2008
- MO‐E‐M100F‐04: Optimizing Low‐Dose Megavoltage Fluoroscopy for 4D RadiotherapyMedical Physics, 2007
- Four‐dimensional cone‐beam computed tomography using an on‐board imagerMedical Physics, 2006
- Megavoltage cone-beam CT: System description and clinical applicationsMedical Dosimetry, 2006
- The application of the sinusoidal model to lung cancer patient respiratory motionMedical Physics, 2005
- Residual motion of lung tumours in gated radiotherapy with external respiratory surrogatesPhysics in Medicine & Biology, 2005
- The correlation between internal and external markers for abdominal tumors: Implications for respiratory gatingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Correlation of lung tumor motion with external surrogate indicators of respirationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRTMedical Physics, 2002
- Respiration gated radiotherapy treatment: a technical studyPhysics in Medicine & Biology, 1996