Radiation exposure during nasojejunal intubation for MRI enteroclysis
- 29 March 2012
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 47 (6) , 658-661
Abstract
Background. Patients with Crohn's disease are often investigated using MRI enteroclysis which may provide better visual quality than MRI enterography, but exposes patients to radiation. Only few data exist of the radiation dose used in fluoroscopy prior to MRI enteroclysis. Subjects and methods. During the 12-month study period, all 95 patients (40 men) undergoing MRI enteroclysis with nasojejunal intubation using fluoroscopy for suspicion or evaluation of Crohn's disease were included. Average age at the time of MRI was 40.1 years (range 17–79). Conversion factors from dose-area product to effective dose were determined with a Monte Carlo-based software PCXMC. The conversion factors were determined for a standard-sized adult phantom for posterior–anterior and right-posterior–oblique projections. Results. The average total time of fluoroscopy was 3 min 17 s (range 0 min 7 s to 31 min). The average effective dose of ionizing radiation was 0.21 mSv (range 0.01–2.67). The average dose is equivalent to 10 PA chest x-rays. Standard deviation was 0.41 mSv. The highest effective dose of a single patient was 2.67 mSv. In comparison, a standard abdominal CT scan causes an effective dose of 12 mSv. Conclusions. The effective dose of ionizing radiation with nasojejunal intubation is relatively small in the majority of patients. When repeated imaging is necessary, it seems advisable to consider imaging techniques, which do not subject patients to ionizing radiation. Also if a previous nasojejunal intubation has been difficult, a different imaging technique is recommended.Keywords
This publication has 19 references indexed in Scilit:
- Patients With IBD are Exposed to High Levels of Ionizing Radiation Through CT Scan Diagnostic ImagingJournal of Clinical Gastroenterology, 2011
- Barium imaging of the small bowel in Crohn’s diseaseColorectal Disease, 2010
- Small bowel MRI enteroclysis or follow through: Which isoptimal?World Journal of Gastroenterology, 2009
- Diagnostic Ionizing Radiation Exposure in a Population-Based Cohort of Patients with Inflammatory Bowel DiseaseAmerican Journal of Gastroenterology, 2008
- MRI of the small bowel with oral contrast or nasojejunal intubation in Crohn's disease: Randomized comparison of patient acceptanceScandinavian Journal of Gastroenterology, 2008
- Quantitative measurement and visual assessment of ileal Crohn's disease activity by computed tomography enterography: correlation with endoscopic severity and C reactive proteinGut, 2006
- Diagnosis of small bowel Crohn’s disease: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysisGut, 2005
- Radiation doses to patients from enteroclysisRadiation Protection Dosimetry, 2005
- Patient radiation doses from enteroclysis examinationsBritish Journal of Radiology, 1994
- Estimation of effective dose to the patient during medical X-ray examinations from measurements of the dose-area productPhysics in Medicine & Biology, 1992