Jouni Uusi-Simola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jouni Uusi-Simola has a total of 126 co-authors. Here are the top co-authors by number of shared publications:
- Iiro Auterinen
VTT Technical Research Centre of Finland, Espoo, Finland
12 shared publications Petri Kotiluoto
6 shared publicationsSauli Savolainen
Helsinki and Uusimaa Hospital District Medical Imaging Center, Helsinki University Central Hospital, Helsinki, Finland
6 shared publicationsTiina Seppälä
6 shared publicationsMika Kortesniemi
5 shared publicationsHanna Koivunoro
4 shared publications
Latest Publications
- Open Access
- 1 April 2020
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 59 (4) , 654-660
Radiation Doses to Staff in a Hybrid Operating Room: An Anthropomorphic Phantom Study with Active Electronic Dosimeters
- 1 April 2020
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 59 (4) , 654-660
Open AccessRadiation Doses to Staff in a Hybrid Operating Room: An Anthropomorphic Phantom Study with Active Electronic Dosimeters
- 1 December 2019
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 58 (6) , e106-e107
Staff Doses and Patient Skin Doses in Hybrid Operating Room Procedures – An Anthropomorphic Phantom Study with Active Electronic Dosimeters
- 1 December 2019
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 58 (6) , e106-e107
Staff Doses and Patient Skin Doses in Hybrid Operating Room Procedures – An Anthropomorphic Phantom Study with Active Electronic Dosimeters
- 1 February 2019
- Published by American Astronomical Society in Research Notes of the AAS
- Vol. 3 (2) , 43
Catalog of New K2 Exoplanet Candidates from Citizen Scientists
- 1 February 2019
- Published by American Astronomical Society in Research Notes of the AAS
- Vol. 3 (2) , 43
Catalog of New K2 Exoplanet Candidates from Citizen Scientists
- 1 May 2013
- Published by Elsevier in Physica Medica
- Vol. 29 (3) , 233-248
Boron neutron capture therapy (BNCT) in Finland: Technological and physical prospects after 20 years of experiences
- 1 May 2013
- Published by Elsevier in Physica Medica
- Vol. 29 (3) , 233-248
Boron neutron capture therapy (BNCT) in Finland: Technological and physical prospects after 20 years of experiences
- 29 March 2012
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 47 (6) , 658-661
Radiation exposure during nasojejunal intubation for MRI enteroclysis
Background. Patients with Crohn's disease are often investigated using MRI enteroclysis which may provide better visual quality than MRI enterography, but exposes patients to radiation. Only few data exist of the radiation dose used in fluoroscopy prior to MRI enteroclysis. Subjects and methods. During the 12-month study period, all 95 patients (40 men) undergoing MRI enteroclysis with nasojejunal intubation using fluoroscopy for suspicion or evaluation of Crohn's disease were included. Average age at the time of MRI was 40.1 years (range 17–79). Conversion factors from dose-area product to effective dose were determined with a Monte Carlo-based software PCXMC. The conversion factors were determined for a standard-sized adult phantom for posterior–anterior and right-posterior–oblique projections. Results. The average total time of fluoroscopy was 3 min 17 s (range 0 min 7 s to 31 min). The average effective dose of ionizing radiation was 0.21 mSv (range 0.01–2.67). The average dose is equivalent to 10 PA chest x-rays. Standard deviation was 0.41 mSv. The highest effective dose of a single patient was 2.67 mSv. In comparison, a standard abdominal CT scan causes an effective dose of 12 mSv. Conclusions. The effective dose of ionizing radiation with nasojejunal intubation is relatively small in the majority of patients. When repeated imaging is necessary, it seems advisable to consider imaging techniques, which do not subject patients to ionizing radiation. Also if a previous nasojejunal intubation has been difficult, a different imaging technique is recommended.
- 29 March 2012
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 47 (6) , 658-661
Radiation exposure during nasojejunal intubation for MRI enteroclysis
Background. Patients with Crohn's disease are often investigated using MRI enteroclysis which may provide better visual quality than MRI enterography, but exposes patients to radiation. Only few data exist of the radiation dose used in fluoroscopy prior to MRI enteroclysis. Subjects and methods. During the 12-month study period, all 95 patients (40 men) undergoing MRI enteroclysis with nasojejunal intubation using fluoroscopy for suspicion or evaluation of Crohn's disease were included. Average age at the time of MRI was 40.1 years (range 17–79). Conversion factors from dose-area product to effective dose were determined with a Monte Carlo-based software PCXMC. The conversion factors were determined for a standard-sized adult phantom for posterior–anterior and right-posterior–oblique projections. Results. The average total time of fluoroscopy was 3 min 17 s (range 0 min 7 s to 31 min). The average effective dose of ionizing radiation was 0.21 mSv (range 0.01–2.67). The average dose is equivalent to 10 PA chest x-rays. Standard deviation was 0.41 mSv. The highest effective dose of a single patient was 2.67 mSv. In comparison, a standard abdominal CT scan causes an effective dose of 12 mSv. Conclusions. The effective dose of ionizing radiation with nasojejunal intubation is relatively small in the majority of patients. When repeated imaging is necessary, it seems advisable to consider imaging techniques, which do not subject patients to ionizing radiation. Also if a previous nasojejunal intubation has been difficult, a different imaging technique is recommended.
- Open Access
- 1 February 2012
- Published by Oxford University Press (OUP) in Journal of Crohn's and Colitis
- Vol. 6 (Supplement) , S50
P101 Radiation exposure during nasojejunal intubation for MRI
L. Puustinen, K. Numminen, J. Uusi-Simola, T. Sipponen; P101 Radiation exposure during nasojejunal intubation for MRI, Journal of Crohn's and Colitis, Volume 6
- 1 February 2012
- Published by Oxford University Press (OUP) in Journal of Crohn's and Colitis
- Vol. 6 (Supplement) , S50
Open AccessP101 Radiation exposure during nasojejunal intubation for MRI
L. Puustinen, K. Numminen, J. Uusi-Simola, T. Sipponen; P101 Radiation exposure during nasojejunal intubation for MRI, Journal of Crohn's and Colitis, Volume 6
- 1 January 2012
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 82 (1) , e67-e75
Boron Neutron Capture Therapy in the Treatment of Locally Recurred Head-and-Neck Cancer: Final Analysis of a Phase I/II Trial
- 1 January 2012
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 82 (1) , e67-e75
Boron Neutron Capture Therapy in the Treatment of Locally Recurred Head-and-Neck Cancer: Final Analysis of a Phase I/II Trial
- 31 December 2011
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 69 (12) , 1901-1903
Effect of the calibration in water and the build-up cap on the Mg(Ar) ionization chamber measurements
- 31 December 2011
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 69 (12) , 1901-1903
Effect of the calibration in water and the build-up cap on the Mg(Ar) ionization chamber measurements
- 18 July 2011
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 50 (6) , 966-972
MRI quality assurance using the ACR phantom in a multi-unit imaging center
Background. Magnetic resonance imaging (MRI) instrumentation is vulnerable to technical and image quality problems, and quality assurance is essential. In the studied regional imaging center the long-term quality assurance has been based on MagNET phantom measurements. American College of Radiology (ACR) has an accreditation program including a standardized image quality measurement protocol and phantom. The ACR protocol includes recommended acceptance criteria for clinical sequences and thus provides possibility to assess the clinical relevance of quality assurance. The purpose of this study was to test the ACR MRI phantom in quality assurance of a multi-unit imaging center. Material and methods. The imaging center operates 11 MRI systems of three major manufacturers with field strengths of 3.0 T, 1.5 T and 1.0 T. Images of the ACR phantom were acquired using a head coil following the ACR scanning instructions. Both ACR T1- and T2-weighted sequences as well as T1- and T2-weighted brain sequences in clinical use at each site were acquired. Measurements were performed twice. The images were analyzed and the results were compared with the ACR acceptance levels. Results. The acquisition procedure with the ACR phantom was faster than with the MagNET phantoms. On the first and second measurement rounds 91% and 73% of the systems passed the ACR test. Measured slice thickness accuracies were not within the acceptance limits in site T2 sequences. Differences in the high contrast spatial resolution between the ACR and the site sequences were observed. In 3.0 T systems the image intensity uniformity was slightly lower than the ACR acceptance limit. Conclusion. The ACR method was feasible in quality assurance of a multi-unit imaging center and the ACR protocol could replace the MagNET phantom tests. An automatic analysis of the images will further improve cost-effectiveness and objectiveness of the ACR protocol.
- 18 July 2011
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 50 (6) , 966-972
MRI quality assurance using the ACR phantom in a multi-unit imaging center
Background. Magnetic resonance imaging (MRI) instrumentation is vulnerable to technical and image quality problems, and quality assurance is essential. In the studied regional imaging center the long-term quality assurance has been based on MagNET phantom measurements. American College of Radiology (ACR) has an accreditation program including a standardized image quality measurement protocol and phantom. The ACR protocol includes recommended acceptance criteria for clinical sequences and thus provides possibility to assess the clinical relevance of quality assurance. The purpose of this study was to test the ACR MRI phantom in quality assurance of a multi-unit imaging center. Material and methods. The imaging center operates 11 MRI systems of three major manufacturers with field strengths of 3.0 T, 1.5 T and 1.0 T. Images of the ACR phantom were acquired using a head coil following the ACR scanning instructions. Both ACR T1- and T2-weighted sequences as well as T1- and T2-weighted brain sequences in clinical use at each site were acquired. Measurements were performed twice. The images were analyzed and the results were compared with the ACR acceptance levels. Results. The acquisition procedure with the ACR phantom was faster than with the MagNET phantoms. On the first and second measurement rounds 91% and 73% of the systems passed the ACR test. Measured slice thickness accuracies were not within the acceptance limits in site T2 sequences. Differences in the high contrast spatial resolution between the ACR and the site sequences were observed. In 3.0 T systems the image intensity uniformity was slightly lower than the ACR acceptance limit. Conclusion. The ACR method was feasible in quality assurance of a multi-unit imaging center and the ACR protocol could replace the MagNET phantom tests. An automatic analysis of the images will further improve cost-effectiveness and objectiveness of the ACR protocol.