Thermoelectric‐based temperature‐controlling system for in‐tube solid‐phase microextraction
- 16 April 2014
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 37 (13) , 1617-1621
Abstract
A temperature‐controlling device for in‐tube solid‐phase microextraction was developed based on thermoelectric cooling and heating. This device can control the temperature of the capillary column from 0 to 100°C by applying a voltage to a Peltier cooler or stainless steel tube. The extraction temperatures for angiotensin I, propranolol, and ranitidine were optimized. In all cases, setting the temperature to 10°C for extraction achieved the best extraction efficiency. Desorption showed minimum peak broadening at 70°C, contributing to better chromatographic performance. Propranolol was selected as a model compound to compare the performance of temperature‐controlled in‐tube solid‐phase microextraction at optimized conditions. Calibration curves exhibited good linearity (R2 > 0.999) over the studied range, and the limit of detection and limit of quantification were about three times lower than those obtained at standard conditions (30°C extraction and desorption).Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- Ontario Ministry of Research and Innovation, and Scholarship funds (Y.Y.)
- the China Scholarship Council
This publication has 13 references indexed in Scilit:
- A new strategy to eliminate sample mixing during in-tube solid phase microextractionJournal of Chromatography A, 2013
- Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columnsInternational Journal of Environmental Analytical Chemistry, 2012
- Automated analysis of lidocaine and its metabolite in plasma by in‐tube solid‐phase microextraction coupled with LC‐UV for pharmacokinetic studyJournal of Separation Science, 2012
- Determination of cortisol in human saliva by automated in-tube solid-phase microextraction coupled with liquid chromatography–mass spectrometryJournal of Pharmaceutical and Biomedical Analysis, 2007
- Determination of telmisartan in rat tissues by in‐tube solid‐phase microextraction coupled to high performance liquid chromatographyJournal of Separation Science, 2006
- Automated on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography for the analysis of bisphenol A, alkylphenols, and phthalate esters in foods contacted with plasticsJournal of Separation Science, 2002
- Automated In-Tube Solid-Phase Microextraction Coupled with Liquid Chromatography/Electrospray Ionization Mass Spectrometry for the Determination of β-Blockers and Metabolites in Urine and Serum SamplesAnalytical Chemistry, 1999
- Automated In-Tube Solid-Phase Microextraction Coupled to High-Performance Liquid ChromatographyAnalytical Chemistry, 1997
- Effect of Heating the Interface on Chromatographic Performance of Solid Phase Microextraction Coupled to High-performance Liquid ChromatographyAnalytical Communications, 1997
- Quantitative Extraction Using an Internally Cooled Solid Phase Microextraction DeviceAnalytical Chemistry, 1995