Increased Peak Contact Stress after Incongruent Reduction of Transverse Acetabular Fractures: A Cadaveric Model
Authors:
- Arthur L. MalkaniAMArthur L. Malkani
- Michael J. VoorMVMichael J. Voor
- Greg RennirtGRGreg Rennirt
- David HelfetDHDavid Helfet
- Douglas PedersenDPDouglas Pedersen
- Thomas BrownTBThomas Brown
- 1 October 2001
- journal article
- research article
- Published by Wolters Kluwer Health
- Vol. 51 (4) , 704-709
Abstract
The objective of this study was to determine the peak contact pressure with varying degrees of articular cartilage step-off in a transtectal acetabular fracture model. Five fresh frozen cadaveric hip joints were potted in a custom loading fixture. The five specimens were then tested at loads of 445 N (newton) (100 lb) and 1,335 N (300 lb) intact and after a transverse osteotomy at step-off levels from 0 to 5 mm in 1-mm increments. Articular cartilage step-off of greater than 1 mm led to significantly increased contact stress at the loaded acetabular articular surface. Mean peak pressure measured at 1,335 N of loading in all intact specimens before the osteotomy was approximately 10 MPa. Peak pressure after a transverse acetabular fracture did not change when the fracture was perfectly reduced. At 1 mm of step-off, the peak pressure increased by approximately 20% but was not statistically significant. With step-off of > 2 mm or greater, the peak pressure increase was approximately 50% and was statistically significant. On the basis of our study, transverse acetabular fractures with greater than 1 mm of displacement can lead to significant increase in peak pressure at the articular surface.Keywords
This publication has 9 references indexed in Scilit:
- Fractures of the AcetabulumJournal of Bone and Joint Surgery, 1996
- The Effect of Variable Size Posterior Wall Acetabular Fractures on Contact Characteristics of the Hip JointJournal of Orthopaedic Trauma, 1996
- Biomechanical consequences of fracture and repair of the posterior wall of the acetabulum.Journal of Bone and Joint Surgery, 1995
- Contact Stress Gradient Detection Limits of Pressensor FilmJournal of Biomechanical Engineering, 1992
- Displaced Acetabular Fractures1991
- Contact pressures in the human hip jointThe Journal of Bone and Joint Surgery. British volume, 1987
- Conservative Treatment of Acetabular Fractures1987
- Fractures of the AcetabulumJournal of Bone and Joint Surgery, 1964
- Prognosis of Fractures of the AcetabulumJournal of Bone and Joint Surgery, 1961