Biodegradable polymer sirolimus-eluting or durable polymer zotarolimus-eluting stents in high bleeding-risk patients with acute coronary syndrome: the BIOFLOW-DAPT randomized trial
- 5 August 2026
- journal article
- Published by Oxford University Press (OUP) in European Heart Journal: Acute Cardiovascular Care
- Vol. 15 (8) , 596-607
Abstract
Aims: Patients at high bleeding risk (HBR) and acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) are at high risk of adverse outcomes. We investigated the clinical outcomes and their consistency after biodegradable polymer sirolimus-eluting (BP-SES) or durable polymer zotarolimus-eluting stent (DP-ZES) implantation in HBR patients with or without ACS. Methods and results: The per-protocol population of the BIOFLOW-DAPT randomized control trial (RCT) consisted of HBR patients with (n = 541) or without ACS (n = 1245) who were randomized to BP-SES or DP-ZES and underwent 1 month dual antiplatelet therapy (DAPT). The primary efficacy and safety endpoints were target lesion failure (TLF), defined as the composite endpoint of cardiac death, target vessel myocardial infarction (TV-MI), or clinically driven target lesion revascularization (cd-TLR) as well as major bleeding defined as BARC 3 or 5 (according to Bleeding Academic Research Consortium classification) and definite/probable stent thrombosis (ST). At 1 year, patients with ACS suffered from higher cardiac death rates (3.4 vs. 1.3%, log-rank P = 0.004) but similar TLF (6.8 vs. 6.7%, P = 0.992), TV-MI (2.8 vs. 4.5%, P = 0.100), cd-TLR (1.4 vs. 2.1%, P = 0.300), major bleeding (4.2 vs. 3.1%, P = 0.266), and ST (0.2 vs. 0.9%, P = 0.098) compared with no ACS patients. The rate of TLF and of all secondary endpoints was consistent with BP-SES or DP-ZES across ACS strata. Conclusion: HBR patients with ACS are at higher risk of cardiac death than those without ACS and experience a consistent outcome with BP-SES or DP-ZES followed by 1 month DAPT at 1 year follow-up. Clinical Trial Registration: NCT04137510.Keywords
This publication has 37 references indexed in Scilit:
- Design and Rationale of the BIOFLOW-DAPT Trial: a Prospective, Randomized, Multicenter Study to Assess the Safety of the Orsiro Mission Stent Compared to the Resolute Onyx Stent in Subjects at High Risk for Bleeding in Combination with 1-Month Dual Antiplatelet TherapyJournal of Cardiovascular Translational Research, 2023
- Abbreviated Antiplatelet Therapy After Coronary Stenting in Patients With Myocardial Infarction at High Bleeding RiskJACC, 2022
- Differential Effects of Newer-Generation Ultrathin-Strut Versus Thicker-Strut Drug-Eluting Stents in Chronic and Acute Coronary SyndromesJACC: Cardiovascular Interventions, 2021
- Duration of Dual Antiplatelet Therapy for Patients at High Bleeding Risk Undergoing PCIJACC, 2021
- 3- or 1-Month DAPT in Patients at High Bleeding Risk Undergoing Everolimus-Eluting Stent ImplantationJACC: Cardiovascular Interventions, 2021
- Trial Design Principles for Patients at High Bleeding Risk Undergoing PCIJACC, 2020
- Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trialThe Lancet, 2014
- Efficacy and safety of intensified antiplatelet therapy on the basis of platelet reactivity testing in patients after percutaneous coronary intervention: Systematic review and meta-analysisInternational Journal of Cardiology, 2013
- Role of Endothelial Shear Stress in Stent Restenosis and ThrombosisJACC, 2012
- Comparison of Everolimus-Eluting and Paclitaxel-Eluting Coronary Stents in Patients Undergoing Multilesion and Multivessel InterventionJACC: Cardiovascular Interventions, 2010