Trabeculectomy with ExPRESS
- 1 March 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 24 (2) , 111-118
Abstract
As glaucoma surgeons continue to search for an improvement over trabeculectomy, the ExPRESS miniature glaucoma shunt has gained interest as a possible contender. Peer-reviewed literature on ExPRESS is beginning to accumulate allowing an evidence-based review to assess the potential benefits and limitations compared to trabeculectomy. The current surgical procedure for ExPRESS implantation will be described followed by results of studies comparing ExPRESS to trabeculectomy, focusing on the following outcomes: success, intraocular pressure, and complications. Case reports of late complications specific to the ExPRESS device will be summarized. Finally, an economic analysis comparing ExPRESS to trabeculectomy will be provided as additional evidence to contribute to the decision matrix on deciding which filtration procedure to recommend. Despite a large number of ExPRESS implant procedures worldwide, there is a paucity of high-quality studies comparing ExPRESS to trabeculectomy. From the available literature to date the outcomes (success and early complications) of ExPRESS are similar to trabeculectomy. Reports of late complications related to device extrusion and malposition are beginning to be published; however, the significantly increased cost for ExPRESS surgery is likely to be the main limitation to widespread adoption of this procedure.Keywords
This publication has 26 references indexed in Scilit:
- Comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised studyEye, 2012
- The first report on intermediate-term outcome of Ex-PRESS® glaucoma filtration device implanted under scleral flap in Japanese patientsClinical Ophthalmology, 2011
- Obstruction of the Ex-PRESS Miniature Glaucoma DeviceJournal of Glaucoma, 2011
- Assessment of Bleb Morphologic Features and Postoperative Outcomes After Ex-PRESS Drainage Device Implantation Versus TrabeculectomyAmerican Journal of Ophthalmology, 2011
- Ex-PRESS Glaucoma Filtration Device—Surgical Technique and OutcomesInternational Ophthalmology Clinics, 2011
- Intermediate‐term results of the Ex‐PRESS miniature glaucoma implant under a scleral flap in previously operated eyesClinical & Experimental Ophthalmology, 2010
- Ex-PRESS Glaucoma Shunt Dislocation Into the Anterior ChamberJournal of Glaucoma, 2008
- Should an iridectomy be routinely performed as a part of trabeculectomy? two surgeons' clinical experienceEye, 2007
- Chlamydia Conjunctivitis and Central Retinal Vein OcclusionAmerican Journal of Ophthalmology, 2005
- Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: A clinical pilot studyAmerican Journal of Ophthalmology, 2004