Quantitation of Mandibular Ramus Volume as a Source of Bone Grafting
- 1 October 2009
- journal article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 11 (s1) , e32-e37
Abstract
Background: When alveolar atrophy impairs dental implant placement, ridge augmentation using mandibular ramus graft may be considered. In live patients, however, an accurate calculation of the amount of bone that can be safely harvested from the ramus has not been reported. The use of a software program to perform these calculations can aid in preventing surgical complications.Purpose: The aim of the present study was to intra‐surgically quantify the volume of the ramus bone graft that can be safely harvested in live patients, and compare it to presurgical computerized tomographic calculations.Materials and Methods: The AutoCAD® software program quantified ramus bone graft in 40 consecutive patients from computerized tomographies. Direct intra‐surgical measurements were recorded thereafter and compared to software data (n = 10). In these 10 patients, the bone volume was also measured at the recipient sites 6 months post‐sinus augmentation.Results: The mandibular second and third molar areas provided the thickest cortical graft averaging 2.8 ± 0.6 mm. The thinnest bone was immediately posterior to the third molar (1.9 ± 0.3 mm). The volume of ramus bone graft measured by AutoCAD averaged 0.8 mL (standard deviation [SD] 0.2 mL, range: 0.4–1.2 mL). The volume of bone graft measured intra‐surgically averaged 2.5 mL (SD 0.4 mL, range: 1.8–3.0 mL). The difference between the two measurement methods was significant (p < 0.001). The bone volume measured 6 months post‐sinus augmentation averaged 2.2 mL (SD 0.4 mL, range: 1.6–2.8 mL) with a mean loss of 0.3 mL in volume.Conclusion: The mandibular second molar area provided the thickest cortical graft. A cortical plate of 2.8 mm in average at combined second and third molar areas provided 2.5 mL particulated volume. The use of a design software program can improve surgical treatment planning prior to ramus bone grafting. The AutoCAD software program did not overestimate the volume of bone that can be safely harvested from the mandibular ramus.Keywords
This publication has 21 references indexed in Scilit:
- Quantitation of Mandibular Symphysis Volume as a Source of Bone GraftingClinical Implant Dentistry and Related Research, 2010
- Morbidity after Chin Bone Harvesting – A Retrospective Long‐Term Follow‐Up StudyClinical Implant Dentistry and Related Research, 2009
- Long‐Term Follow‐Up and Tomographic Assessment of an Intrabony Defect Treated With Enamel Matrix DerivativeJournal of Periodontology, 2008
- Quantitative assessment of early healing of intramembranous and endochondral autogenous bone grafts using micro-computed tomography and Q-win image analyzerInternational Journal of Oral and Maxillofacial Surgery, 2004
- Evaluation of the Mandible as an Alternative Autogenous Bone Source for Oral and Maxillofacial ReconstructionJournal of International Medical Research, 2002
- Clinical Application of a New Compact Computed Tomography System for Evaluating the Outcome of Regenerative Therapy: A Case ReportJournal of Periodontology, 2001
- Evaluation of a microcomputed tomography system to study trabecular bone structureJournal of Orthopaedic Research, 1990
- The direct examination of three-dimensional bone architecture in vitro by computed tomographyJournal of Bone and Mineral Research, 1989
- Membranous versus Endochondral BonePlastic and Reconstructive Surgery, 1983
- Repair of Bone GraftsScandinavian Journal of Plastic and Reconstructive Surgery, 1980