Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction
- 2 October 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (5) , 2665-2675
Abstract
Purpose: Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short‐axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine datasets; reformatted slices are then used to optimize the manual segmentation workflow.Methods: Isotropic 3D cine datasets were obtained from multiple 2D cine stacks (acquired during free‐breathing in SAX and long‐axis (LAX) orientations) using nonrigid motion correction (cine‐GRICS method) and super‐resolution. Several manual segmentation strategies were then compared, including conventional SAX segmentation, LAX segmentation in three views only, and combinations of SAX and LAX slices. An implicit B‐spline surface reconstruction algorithm is proposed to reconstruct the left ventricular cavity surface from the sparse set of 2D contours.Results: All tested sparse segmentation strategies were in good agreement, with Dice scores above 0.9 despite using fewer slices (3–6 sparse slices instead of 8–10 contiguous SAX slices). When compared to independent phase‐contrast flow measurements, stroke volumes computed from four or six sparse slices had slightly higher precision than conventional SAX segmentation (error standard deviation of 5.4 mL against 6.1 mL) at the cost of slightly lower accuracy (bias of −1.2 mL against 0.2 mL). Functional parameters also showed a trend to improved precision, including end‐diastolic volumes, end‐systolic volumes, and ejection fractions).Conclusion: The postprocessing workflow of 3D isotropic cardiac imaging strategies can be optimized using sparse segmentation and 3D surface reconstruction. Magn Reson Med 79:2665–2675, 2018. © 2017 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- European Commission (605162)
This publication has 31 references indexed in Scilit:
- Single-image super-resolution of brain MR images using overcomplete dictionariesMedical Image Analysis, 2013
- Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agentJournal of Cardiovascular Magnetic Resonance, 2012
- Free‐breathing imaging of the heart using 2D cine‐GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and functionJournal of Magnetic Resonance Imaging, 2011
- Accelerating global left-ventricular function assessment in mice using reduced slice acquisition and three-dimensional guide-point modellingJournal of Cardiovascular Magnetic Resonance, 2011
- Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free‐breathing MRIMagnetic Resonance in Medicine, 2008
- Feasibility of single breath-hold left ventricular function with 3 Tesla TSENSE acquisition and 3D modeling analysisJournal of Cardiovascular Magnetic Resonance, 2008
- Whole‐heart cine MRI using real‐time respiratory self‐gatingMagnetic Resonance in Medicine, 2007
- Registration-Based Approach for Reconstruction of High-Resolution In Utero Fetal MR Brain ImagesAcademic Radiology, 2006
- MR imaging assessment of cardiac functionJournal of Magnetic Resonance Imaging, 2004
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002