Development of a Robust Autofluorescence Lifetime Sensing Method for Use in an Endoscopic Application
Open Access
Abstract
Endoscopic autofluorescence lifetime imaging is a promising technique for making quantitative and non-invasive diagnoses of abnormal tissue. However, motion artifacts caused by vibration in the direction perpendicular to the tissue surface in a body makes clinical diagnosis difficult. Thus, this paper proposes a robust autofluorescence lifetime sensing technique with a lens tracking system based on a laser beam spot analysis. Our optical setup can be easily mounted on the head of an endoscope. The variation in distance between the optical system and the target surface is tracked by the change in the spot size of the laser beam captured by the camera, and the lens actuator is feedback-controlled to suppress motion artifacts. The experimental results show that, when using a lens tracking system, the standard deviation of fluorescence lifetime is dramatically reduced. Furthermore, the validity of the proposed method is experimentally confirmed by using a bio-mimicking phantom that replicates the shape, optical parameters, and chemical component distribution of the cancerous tissue.Keywords
This publication has 25 references indexed in Scilit:
- Endoscopic Fluorescence Lifetime Imaging for In Vivo Intraoperative Diagnosis of Oral CarcinomaMicroscopy and Microanalysis, 2013
- pH Dependence of the Fluorescence Lifetime of FAD in Solution and in CellsInternational Journal of Molecular Sciences, 2013
- Auto-fluorescence lifetime and light reflectance spectroscopy for breast cancer diagnosis: potential tools for intraoperative margin detectionBiomedical Optics Express, 2012
- Fluorescence lifetime imaging microscopy for brain tumor image-guided surgeryJournal of Biomedical Optics, 2010
- Fluorescence Lifetime Measurements and Biological ImagingChemical Reviews, 2010
- Using an oblique incident laser beam to measure the optical properties of stomach mucosa/submucosa tissueBMC Gastroenterology, 2009
- Usefulness and safety of 0.4% sodium hyaluronate solution as a submucosal fluid "cushion" for endoscopic resection of colorectal mucosal neoplasms: A prospective multi-center open-label trialBMC Gastroenterology, 2009
- In vivo multiphoton microscopy of NADH and FAD redox states, fluorescence lifetimes, and cellular morphology in precancerous epitheliaProceedings of the National Academy of Sciences of the United States of America, 2007
- Real-time time-domain fluorescence lifetime imaging including single-shot acquisition with a segmented optical image intensifierNew Journal of Physics, 2004
- Fluorescence Lifetime Imaging Microscopy (FLIM): Instrumentation and ApplicationsCritical Reviews in Analytical Chemistry, 1992