Masaaki Hashimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masaaki Hashimoto has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yoshihiro Taguchi
Department of System Design Engineering, Keio University, Yokohama, Japan
6 shared publications - Abdulkareem Alasli
Department of Mechanical Systems Engineering, Nagoya University, Nagoya, Japan
2 shared publications - Ai Ueno
Department of Mechanical Systems Engineering, Graduate School of Engineering Nagoya University Nagoya Aichi Japan
2 shared publications - Hosei Nagano
Nagoya University
2 shared publications - Ryobu Nomura
Department of Mechanical System Engineering, Nagoya University, Nagoya, Japan
2 shared publications Yoshihiro Taguchi
Keio University,Department of System Design Engineering,Yokohama,Japan
2 shared publications
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Self-replenishing soft actuator driven by liquid–gas phase change of harvested atmospheric moisture
- 24 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Open AccessSelf-replenishing soft actuator driven by liquid–gas phase change of harvested atmospheric moisture
- Open Access
- 14 March 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 272
Thermal performance evaluation of a parylene-coated polydimethylsiloxane loop heat pipe featuring a micropillar evaporator
- 14 March 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 272
Open AccessThermal performance evaluation of a parylene-coated polydimethylsiloxane loop heat pipe featuring a micropillar evaporator
- Open Access
- 10 January 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (2) , 025004
Quadrant kirigami-type electrothermal MEMS actuator with multi-degree-of-freedom morphing capability
Kirigami design principles have been widely applied to develop thermally responsive shape-morphing devices across various scales. However, the multi-degree-of-freedom (multi-DoF) morphing capabilities of microelectromechanical-systems (MEMS)-scale kirigami devices under localized Joule heating remain largely unexplored. This paper presents a quadrant kirigami-type electrothermal MEMS actuator with multi-DoF morphing capabilities, demonstrating both one-dimensional piston motion and two-dimensional (2D) tilting motion. The actuator, fabricated using surface and bulk micromachining techniques, features four independent electrical circuits, creating four electrothermally separated quadrants within the MEMS-scale kirigami structure. The temperature distribution within each quadrant of the actuator, subjected to localized Joule heating, was experimentally examined using thermography, revealing distinct temperature contrasts. The actuator demonstrated multi-DoF morphing capabilities, achieving a 2D tilting angular displacement of approximately 10° at 70 mW and a vertical piston displacement of 1.5 mm at 135 mW. These experimental results validate that the electrothermal quadrant design, leveraging localized Joule heating, enhances the DoF morphing capabilities of kirigami-type electrothermal MEMS actuators.
- 10 January 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (2) , 025004
Open AccessQuadrant kirigami-type electrothermal MEMS actuator with multi-degree-of-freedom morphing capability
Kirigami design principles have been widely applied to develop thermally responsive shape-morphing devices across various scales. However, the multi-degree-of-freedom (multi-DoF) morphing capabilities of microelectromechanical-systems (MEMS)-scale kirigami devices under localized Joule heating remain largely unexplored. This paper presents a quadrant kirigami-type electrothermal MEMS actuator with multi-DoF morphing capabilities, demonstrating both one-dimensional piston motion and two-dimensional (2D) tilting motion. The actuator, fabricated using surface and bulk micromachining techniques, features four independent electrical circuits, creating four electrothermally separated quadrants within the MEMS-scale kirigami structure. The temperature distribution within each quadrant of the actuator, subjected to localized Joule heating, was experimentally examined using thermography, revealing distinct temperature contrasts. The actuator demonstrated multi-DoF morphing capabilities, achieving a 2D tilting angular displacement of approximately 10° at 70 mW and a vertical piston displacement of 1.5 mm at 135 mW. These experimental results validate that the electrothermal quadrant design, leveraging localized Joule heating, enhances the DoF morphing capabilities of kirigami-type electrothermal MEMS actuators.
- Open Access
- 20 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 32 (6) , 519-521
Design and Fabrication of a Micropillar-Pumped Polymer Loop Heat Pipe
This letter presents a micropillar-pumped polymer loop heat pipe (LHP) with potential applications in flexible electronics. A unique evaporator with a micro pillar wick was designed for a flexible polymer LHP. The polymer LHP was fabricated via simple and cost-effective soft lithography, omitting the need for a porous wick. This design and fabrication approach facilitated passive two-phase cooling in the polymer LHP, with up to 34 $^{\circ}$ C reduction in evaporator temperature when compared to a non-fluid-charged state in a horizontal orientation. 2023-0140
- 20 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 32 (6) , 519-521
Open AccessDesign and Fabrication of a Micropillar-Pumped Polymer Loop Heat Pipe
This letter presents a micropillar-pumped polymer loop heat pipe (LHP) with potential applications in flexible electronics. A unique evaporator with a micro pillar wick was designed for a flexible polymer LHP. The polymer LHP was fabricated via simple and cost-effective soft lithography, omitting the need for a porous wick. This design and fabrication approach facilitated passive two-phase cooling in the polymer LHP, with up to 34 $^{\circ}$ C reduction in evaporator temperature when compared to a non-fluid-charged state in a horizontal orientation. 2023-0140
- 26 May 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (12) , 17457-17467
Circular pyramidal kirigami microscanner with millimeter-range low-power lens drive
This paper proposes an electrothermally-actuated circular pyramidal kirigami microscanner with a millimeter-range low-power lens drive for endoscopic biomedical applications. A variation of Japanese origami art, kirigami involves creation of out-of-plane structures by paper cutting and folding. The proposed microscanner is composed of freestanding kirigami film on which the spiral-curved thermal bimorphs are strategically placed. The kirigami microscanner is electrothermally transformed into an out-of-plane circular multistep pyramid by Joule heating. The circular pyramidal kirigami microscanner on a small footprint of 4.5 mm × 4.5 mm was fabricated by microelectromechanical system processes. A large four-step pyramidal actuation was successfully demonstrated, and a large 1.1-mm lens travel range at only 128 mW was achieved.
- 26 May 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (12) , 17457-17467
Circular pyramidal kirigami microscanner with millimeter-range low-power lens drive
This paper proposes an electrothermally-actuated circular pyramidal kirigami microscanner with a millimeter-range low-power lens drive for endoscopic biomedical applications. A variation of Japanese origami art, kirigami involves creation of out-of-plane structures by paper cutting and folding. The proposed microscanner is composed of freestanding kirigami film on which the spiral-curved thermal bimorphs are strategically placed. The kirigami microscanner is electrothermally transformed into an out-of-plane circular multistep pyramid by Joule heating. The circular pyramidal kirigami microscanner on a small footprint of 4.5 mm × 4.5 mm was fabricated by microelectromechanical system processes. A large four-step pyramidal actuation was successfully demonstrated, and a large 1.1-mm lens travel range at only 128 mW was achieved.
- Open Access
- 30 March 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 362
Design and Fabrication of a Kirigami-Inspired Electrothermal MEMS Scanner with Large Displacement
Large-displacement microelectromechanical system (MEMS) scanners are in high demand for a wide variety of optical applications. Kirigami, a traditional Japanese art of paper cutting and folding, is a promising engineering method for creating out-of-plane structures. This paper explores the feasibility and potential of a kirigami-inspired electrothermal MEMS scanner, which achieves large vertical displacement by out-of-plane film actuation. The proposed scanner is composed of film materials suitable for electrothermal self-reconfigurable folding and unfolding, and microscale film cuttings are strategically placed to generate large displacement. The freestanding electrothermal kirigami film with a 2 mm diameter and high fill factor is completely fabricated by careful stress control in the MEMS process. A 200 μm vertical displacement with 131 mW and a 20 Hz responsive frequency is experimentally demonstrated as a unique function of electrothermal kirigami film. The proposed design, fabrication process, and experimental test validate the proposed scanner’s feasibility and potential for large-displacement scanning with a high fill factor.
- 30 March 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 362
Open AccessDesign and Fabrication of a Kirigami-Inspired Electrothermal MEMS Scanner with Large Displacement
Large-displacement microelectromechanical system (MEMS) scanners are in high demand for a wide variety of optical applications. Kirigami, a traditional Japanese art of paper cutting and folding, is a promising engineering method for creating out-of-plane structures. This paper explores the feasibility and potential of a kirigami-inspired electrothermal MEMS scanner, which achieves large vertical displacement by out-of-plane film actuation. The proposed scanner is composed of film materials suitable for electrothermal self-reconfigurable folding and unfolding, and microscale film cuttings are strategically placed to generate large displacement. The freestanding electrothermal kirigami film with a 2 mm diameter and high fill factor is completely fabricated by careful stress control in the MEMS process. A 200 μm vertical displacement with 131 mW and a 20 Hz responsive frequency is experimentally demonstrated as a unique function of electrothermal kirigami film. The proposed design, fabrication process, and experimental test validate the proposed scanner’s feasibility and potential for large-displacement scanning with a high fill factor.
- Open Access
Development of a Robust Autofluorescence Lifetime Sensing Method for Use in an Endoscopic Application
Endoscopic autofluorescence lifetime imaging is a promising technique for making quantitative and non-invasive diagnoses of abnormal tissue. However, motion artifacts caused by vibration in the direction perpendicular to the tissue surface in a body makes clinical diagnosis difficult. Thus, this paper proposes a robust autofluorescence lifetime sensing technique with a lens tracking system based on a laser beam spot analysis. Our optical setup can be easily mounted on the head of an endoscope. The variation in distance between the optical system and the target surface is tracked by the change in the spot size of the laser beam captured by the camera, and the lens actuator is feedback-controlled to suppress motion artifacts. The experimental results show that, when using a lens tracking system, the standard deviation of fluorescence lifetime is dramatically reduced. Furthermore, the validity of the proposed method is experimentally confirmed by using a bio-mimicking phantom that replicates the shape, optical parameters, and chemical component distribution of the cancerous tissue.
Open AccessDevelopment of a Robust Autofluorescence Lifetime Sensing Method for Use in an Endoscopic Application
Endoscopic autofluorescence lifetime imaging is a promising technique for making quantitative and non-invasive diagnoses of abnormal tissue. However, motion artifacts caused by vibration in the direction perpendicular to the tissue surface in a body makes clinical diagnosis difficult. Thus, this paper proposes a robust autofluorescence lifetime sensing technique with a lens tracking system based on a laser beam spot analysis. Our optical setup can be easily mounted on the head of an endoscope. The variation in distance between the optical system and the target surface is tracked by the change in the spot size of the laser beam captured by the camera, and the lens actuator is feedback-controlled to suppress motion artifacts. The experimental results show that, when using a lens tracking system, the standard deviation of fluorescence lifetime is dramatically reduced. Furthermore, the validity of the proposed method is experimentally confirmed by using a bio-mimicking phantom that replicates the shape, optical parameters, and chemical component distribution of the cancerous tissue.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 152-153
Kirigami-inspired Electrothermal Actuator for Motion Tracking Blood Flow Measurement
A large stroke electrothermal MEMS actuator with small device footprint and low driving voltage has been proposed for motion tracking blood flow measurement. This paper reports this kirigami-inspired device design and simulation results of the proposed actuator.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 152-153
Kirigami-inspired Electrothermal Actuator for Motion Tracking Blood Flow Measurement
A large stroke electrothermal MEMS actuator with small device footprint and low driving voltage has been proposed for motion tracking blood flow measurement. This paper reports this kirigami-inspired device design and simulation results of the proposed actuator.
- Open Access
Motion Tracking System for Robust Non-Contact Blood Perfusion Sensor
We propose a motion-robust laser Doppler flowmetry (LDF) system that can be used as a non-contact blood perfusion sensor for medical diagnosis. Endoscopic LDF systems are typically limited in their usefulness in clinical contexts by the need for the natural organs to be immobilized, as serious motion artifacts due to the axial surface displacement can interfere with blood perfusion measurements. In our system, the focusing lens moves to track the motion of the target using a low-frequency reference signal in the optical data, enabling the suppression of these motion artifacts in the axial direction. This paper reports feasibility tests on a prototype of this system using a microfluidic phantom as a measurement target moving in the direction of the optical axis. The frequency spectra detected and the perfusion values calculated from those spectra show that the motion tracking system is capable of suppressing motion artifacts in perfusion readings. We compared the prototype LDF system’s measurements with and without motion feedback, and found that motion tracking improves the fidelity of the perfusion signal by as much as 87%.
Open AccessMotion Tracking System for Robust Non-Contact Blood Perfusion Sensor
We propose a motion-robust laser Doppler flowmetry (LDF) system that can be used as a non-contact blood perfusion sensor for medical diagnosis. Endoscopic LDF systems are typically limited in their usefulness in clinical contexts by the need for the natural organs to be immobilized, as serious motion artifacts due to the axial surface displacement can interfere with blood perfusion measurements. In our system, the focusing lens moves to track the motion of the target using a low-frequency reference signal in the optical data, enabling the suppression of these motion artifacts in the axial direction. This paper reports feasibility tests on a prototype of this system using a microfluidic phantom as a measurement target moving in the direction of the optical axis. The frequency spectra detected and the perfusion values calculated from those spectra show that the motion tracking system is capable of suppressing motion artifacts in perfusion readings. We compared the prototype LDF system’s measurements with and without motion feedback, and found that motion tracking improves the fidelity of the perfusion signal by as much as 87%.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of electrothermal lens actuator for endoscopic blood flow sensor
A novel blood flow sensor enabling a precise measurement in an endoscope has been developed. In this paper, a device design and a validity of an electrothermal actuator for the lens control are reported.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of electrothermal lens actuator for endoscopic blood flow sensor
A novel blood flow sensor enabling a precise measurement in an endoscope has been developed. In this paper, a device design and a validity of an electrothermal actuator for the lens control are reported.