A novel computational analysis of computer milled zirconium implant abutment head design under reinforced implant supported overdenture
- 1 January 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Abstract
During the past few decades, unalloyed titanium has been extensively used as a material of dental implant-supported restorations but it cause gingival discoloration and unnatural appearance of the surrounding soft tissue. Currently, yttrium oxide partially-stabilized zirconia (Y-TZP) is a ceramic of special interest because of its superior mechanical properties. This study was carried out with four one piece zirconium implants embedded on a standard acrylic resin mandibular edentulous model, the abutment of zirconium implant was classified into two designs and then laboratory test was applied with proposed biting force (sensor (BS) and a bidirectional transmit-receive module. Our study concluded that the use of one piece Zirconium implant with box or parallel shape abutment head in implant supported over-denture without a need of cement, screws or plastics or metal housing for attachment in other types of implant had a superior results and easier maintenance and repair of the prosthesis if any complications occur.Keywords
This publication has 22 references indexed in Scilit:
- A bio-sensory system for increase implant longevity for occlusal analysis2012
- The evaluation of flexural strength and impact strength of heat-polymerized polymethyl methacrylate denture base resin reinforced with glass and nylon fibers: An in vitro studyThe Journal of Indian Prosthodontic Society, 2008
- Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAMJournal of Dentistry, 2007
- The static strength and modulus of fiber reinforced denture base polymerDental Materials, 2005
- A novel sensor for bite force determinationsDental Materials, 2003
- A new device for measuring mastication force (Gnathodynamometer)Annals of Anatomy - Anatomischer Anzeiger, 2002
- An investigation into the transverse and impact strength of `high strength' denture base acrylic resinsJournal of Oral Rehabilitation, 2002
- 3‐D in vivo force measurements on mandibular implants supporting overdentures. A comparative study.Clinical Oral Implants Research, 1996
- Limits of human bite strengthThe Journal of Prosthetic Dentistry, 1986
- Isometric Bite Force and its Relation to General Muscle Forge and Body BuildActa Odontologica Scandinavica, 1970