Glomerular filtration rate calculation based on 68Ga-EDTA dynamic renal PET
- 1 January 2022
- journal article
- research article
- Vol. 12 (2) , 54-62
Abstract
Positron emission tomography (PET) can accurately locate and quantify radioactivity over traditional single photon emission computed tomography (SPECT), encouraging its application in kidney function evaluation and glomerular filtration rate (GFR) measurement Ga-68-ethylenediamine-tetraacetic acid (Ga-68-EDTA) is a novel PET tracer for renal scan but a mature GFR calculation method still pending establishment. Herein, we aim to investigate the imaging performance of Ga-68-EDTA dynamic PET in healthy C57BL/6 mice, establish quantitative methods to calculate GFR, and evaluate its feasibility in mice with kidney dysfunction. Dynamic PET of Ga-68-EDTA successfully visualized the whole process of tracer elimination. GFR values were measured by the integral method (253.80 +/- 40.11 mu L/min) and the Patlak Plot method (22.69 +/- 9.75 mu L/min), while blood clearance rate of the tracer was found at 787.46 +/- 70.86 mu L/min. The PET-based GFR values correlate well with the GFR(blood) (R-2 =0.7468, R-2 =0.8793). The Integral method provides better accuracy than Patlak Plot method. Further application of GFR measurement in kidney-diseased mice proves better performance of the Integral method for defining split renal function.Keywords
This publication has 23 references indexed in Scilit:
- 68Ga-EDTA PET/CT Imaging and Plasma Clearance for Glomerular Filtration Rate Quantification: Comparison to Conventional 51Cr-EDTAJournal of Nuclear Medicine, 2015
- Preparation of Ga-68-NOTA as a renal PET agent and feasibility tests in miceNuclear Medicine and Biology, 2014
- Evaluation of glomerular filtration rate by use of dynamic computed tomography and Patlak analysis in clinically normal catsAmerican Journal of Veterinary Research, 2011
- Calculation of glomerular filtration rate in conscious rats by the use of a bolus injection of iodixanol and a single blood sampleJournal of Pharmacological and Toxicological Methods, 2010
- Measured GFR as a Confirmatory Test for Estimated GFRJournal of the American Society of Nephrology, 2009
- Dynamic 18F-fluoride small animal PET to noninvasively assess renal function in ratsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Renal Structural and Functional Repair in a Mouse Model of Reversal of Ureteral ObstructionJournal of the American Society of Nephrology, 2005
- Glomerular filtration rate measured using the Patlak plot technique and contrast‐enhanced dynamic MRI with different amounts of gadolinium‐DTPAJournal of Magnetic Resonance Imaging, 2005
- Serial determination of glomerular filtration rate in conscious mice using FITC-inulin clearanceAmerican Journal of Physiology-Renal Physiology, 2004
- Measurement of single‐kidney glomerular filtration rate using a contrast‐enhanced dynamic gradient‐echo sequence and the Rutland‐Patlak plot techniqueJournal of Magnetic Resonance Imaging, 2003