Yuqing Liu
Research Subjects
Research Interests
Yuqing Liu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Dawei Jiang
Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Nucl Med, Wuhan 430022, Hubei, Peoples R China
1 shared publicationDu Zhang
Univ Sci & Technol China, Sch Informat Sci & Technol, Hefei 230026, Peoples R China
1 shared publicationLi Zhang
Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Nucl Med, Wuhan 430022, Hubei, Peoples R China
1 shared publicationMin Wang
Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Nucl Med, Wuhan 430022, Hubei, Peoples R China
1 shared publication- Wei Cao
Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
1 shared publication Ying Ding
Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Nucl Med, Wuhan 430022, Hubei, Peoples R China
1 shared publication
Latest Publications
- 1 January 2022
- Vol. 12 (2) , 54-62
Glomerular filtration rate calculation based on 68Ga-EDTA dynamic renal PET
Positron emission tomography (PET) can accurately locate and quantify radioactivity over traditional single photon emission computed tomography (SPECT), encouraging its application in kidney function evaluation and glomerular filtration rate (GFR) measurement Ga-68-ethylenediamine-tetraacetic acid (Ga-68-EDTA) is a novel PET tracer for renal scan but a mature GFR calculation method still pending establishment. Herein, we aim to investigate the imaging performance of Ga-68-EDTA dynamic PET in healthy C57BL/6 mice, establish quantitative methods to calculate GFR, and evaluate its feasibility in mice with kidney dysfunction. Dynamic PET of Ga-68-EDTA successfully visualized the whole process of tracer elimination. GFR values were measured by the integral method (253.80 +/- 40.11 mu L/min) and the Patlak Plot method (22.69 +/- 9.75 mu L/min), while blood clearance rate of the tracer was found at 787.46 +/- 70.86 mu L/min. The PET-based GFR values correlate well with the GFR(blood) (R-2 =0.7468, R-2 =0.8793). The Integral method provides better accuracy than Patlak Plot method. Further application of GFR measurement in kidney-diseased mice proves better performance of the Integral method for defining split renal function.
- 1 January 2022
- Vol. 12 (2) , 54-62
Glomerular filtration rate calculation based on 68Ga-EDTA dynamic renal PET
Positron emission tomography (PET) can accurately locate and quantify radioactivity over traditional single photon emission computed tomography (SPECT), encouraging its application in kidney function evaluation and glomerular filtration rate (GFR) measurement Ga-68-ethylenediamine-tetraacetic acid (Ga-68-EDTA) is a novel PET tracer for renal scan but a mature GFR calculation method still pending establishment. Herein, we aim to investigate the imaging performance of Ga-68-EDTA dynamic PET in healthy C57BL/6 mice, establish quantitative methods to calculate GFR, and evaluate its feasibility in mice with kidney dysfunction. Dynamic PET of Ga-68-EDTA successfully visualized the whole process of tracer elimination. GFR values were measured by the integral method (253.80 +/- 40.11 mu L/min) and the Patlak Plot method (22.69 +/- 9.75 mu L/min), while blood clearance rate of the tracer was found at 787.46 +/- 70.86 mu L/min. The PET-based GFR values correlate well with the GFR(blood) (R-2 =0.7468, R-2 =0.8793). The Integral method provides better accuracy than Patlak Plot method. Further application of GFR measurement in kidney-diseased mice proves better performance of the Integral method for defining split renal function.